Loading...
HomeMy WebLinkAboutWS CAT, Stormwater Plan , Sheet (3) V1Page 2 221182 1.3 Design Criteria The stormwater facilities were designed in accordance with the ACHD Policy Manual Section 8000 and Section 8200 relating to stormwater. See appendix B for calculations. The design criteria for this seepage beds are: ▪ Store 100-year storm event at a 1-hour duration ▪ Infiltrate the 90% storm in 48 hours ▪ Minimum cover of 1.5-feet, unless under roadway or sidewalk then the minimum cover is 1-foot ▪ Washed Drain Rock is 1.5-2 inches ▪ 1.5 -feet of ASTM C33 filter sand ▪ Sediment increase factor of 25% ▪ 3-feet minimum from groundwater 1.4 Calculations 1.4.1 Design Inputs ▪ Total acreage included in calculations is 0.97 acres. ▪ The runoff coefficient for the future building is 0.95 with a total area of 10,194 square feet. ▪ The runoff coefficient for concrete and asphalt is 0.90, with a total area of 32,663 square feet. ▪ The runoff coefficient for landscaping is 0.20, with a total area of 12,526 square feet. ▪ Time of concentration is 5 minutes. ▪ Sedimentation Increase Factor is 1.25 1.4.2 Summary of Calculations ▪ Seepage bed dimensions – 65’ X 25’ X 6’ ▪ Seepage bed storage volume – 3900 CF ▪ Storm drainpipe sized for 100-year event – 12” Diameter ▪ Sand and grease trap size sized for 25-year event See appendix B for calculations. 12/27/21 A-2021-0223