Loading...
HomeMy WebLinkAbout08 WS CAT, Landscape Plan Sheet (3) V1ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L SAW SAW SAW SAW 1 2 2 EXISTING TREES TO REMAIN PLANTS TO BE INSTALLED CUT EDGE, SEE DETAIL 2/L2.0 RTF TURF TYPE TALL FESCUE SOD OVER APPROVED TOPSOIL AS SPECIFIED SELECT MULCH IN PLANTING BEDS OVER APPROVED TOPSOIL AS SPECIFIED. EXISTING TURF TO BE RETAINED AND PROTECTED LANDSCAPE TO BE REMOVED. LANDSCAPE LEGEND EXISTING TREES TO BE REMOVED RELOCATE EXISTING MEMORIAL TREE AND FLAG POLE PER OWNER. NON-QUALIFYING TREE. DYING. DO NOT SAVE. TO BE REMOVED. MITIGATION DOES NOT APPLY. CALLOUT LEGEND 1 2 L1.1 TREES NOTED SHALL BE REMOVED AND REPLACED WITH HYDRAULIC TREE SPADE. SPADE SHALL HAVE A CAPACITY FOR A MINIMUM ROOT BALL DIAMETER AS NOTED AND A MINIMUM ROOT BALL DEPTH AS NOTED. ONE FULL DAY BEFORE TRANSPLANT, ALL DECIDUOUS TREES SHALL BE SPRAYED WITH AN ANTI-TRANSPIRANT (WILT-PRUF OR EQUAL) TO ALL OF THE FOLIAGE (TOP AND BOTTOM) AS PER MANUFACTURER'S RECOMMENDATIONS. THE TREE TRANSPLANT SHALL BE DONE IN ONE CONTINUOUS PROCESS AND THE PREVIOUSLY DUG RECEIVING THE NEW LOCATION FILL. HOLE SIDES SHALL BE SCARIFIED. A PLANTING MIXTURE OF ONE PART PEAT MOSS TO THREE PARTS TOPSOIL WITH AGRO 'TRANSPLANTER', 4-2-4 (OR APPROVED EQUAL, USE AS PER MANUFACTURER'S RECOMMENDATIONS) SHALL BE MIXED WITH WATER TO FORM A SLURRY. THE SLURRY MIXTURE SHALL FILL ANY VOIDS AROUND THE ROOTBALL, ELIMINATING ANY AIR POCKETS. AGRIFORM PLANTING TABLETS 20-15-5 (OR APPROVED EQUAL) SHALL BE INSTALLED. TABLET QUANTITY BASED UPON PLANT SIZE AS PER MANUFACTURER'S RECOMMENDATIONS. TREE SPADE SIZE DECIDUOUS TREE - TRUNK DIAMETER EVERGREEN TREE - HEIGHT 44 INCHES 2 TO 4 INCHES 5 TO 7 FEET 66 INCHES 4 TO 6 INCHES 7 TO 10 FEET 92 INCHES 6 TO 10 INCHES 12 TO 15 FEET TRUNK DIAMETERS ARE MEASURED USING A CALIPER, SIX INCHES ABOVE THE GROUND FOR TREE FOUR INCHES IN DIAMETER OR SMALLER AND 12 INCHES ABOVE THE GROUND FOR TREES WITH A LARGE DIAMETER. NOTE: THE INDUSTRY STANDARD IS 1:10. (10 INCHES OF ROOTBALL FOR EVERY INCH OF TRUNK CALIPER) TREE PROTECTION NOTES: TREE TRANSPLANT NOTES: 1. PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE) OF THE TREES TO REMAIN ON SITE BY: a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE TREE TO BE PROTECTED PRIOR TO DEMOLITION, CONSTRUCTION, OR ANY SITE WORK. b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION. c. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR ANYWHERE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE WASHOUT AREAS. d. NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION AREA. e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK. f. NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL WITHIN THE CRITICAL ROOT ZONE. g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS. 2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY: a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES. b. HAVING TREES PRUNED BY A LICENSED ARBORIST. 3. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE MITIGATED USING THE MITIGATION STANDARDS AS SET FORTH IN THE CURRENT CITY CODE. TREE PROTECTION DETAIL NOT TO SCALE OUTLINE OF TREE CROWN (EDGE OF DRIPLINE) CORRESPONDING WITH ROOT SPREAD. FENCE SHALL BE PLACED AT EDGE OF TREE CROWN (MINIMUM DISTANCE). EXISTING GRADE NOTE: MAINTAIN PROTECTION UNTIL CONSTRUCTION ACTIVITIES ARE COMPLETED. IF LOWER LIMBS INTERFERE WITH WORK, TIE UP WITH HEAVY JUTE CORD. ADJUST DIAMETER OF PROTECTIVE FENCE TO PREVENT ANTICIPATED DAMAGE BY EQUIPMENT. TREE TRUNK CROWN OF TREE. OUTLINE OF TREE CROWN (EDGE OF DRIPLINE) CORRESPONDING WITH ROOT SPREAD. FENCE SHALL BE PLACED AT EDGE OF TREE CROWN (MINIMUM DISTANCE). SECTION PLAN VIEW TREE CROWN FENCE LINE # W OVERLAND ROAD TREE MITIGATION NOTES: 1. THE EXISTING TREES TO BE REMOVED THAT REQUIRE MITIGATION ARE AS FOLLOWS FROM THE INTERIOR OF THE SITE (AS NOTED ON PLAN): - (1) 4" CAL. MAPLE = 4" - (4) 8" CAL. MAPLE = 32" - (2) 6" CAL. CHOKECHERRY = 12" - (5) 12" CAL. ASH = 60" - (1) 12" CAL. MAPLE = 12" - (2) 15" CAL. MAPLE = 30" - (3) 11" CAL. ASH = 33" - (1) 8" CAL. LINDEN = 8" - (1) 12" CAL. LINDEN = 12" - (1) 12" CAL. PINE = 12" - (1) 18" CAL. PINE = 18" - (2) 12" CAL. SPRUCE = 24" - (1) 10" CAL. CHOKE CHERRY = 10" - (1) 6" CAL. PEAR = 6" TOTAL CALIPER INCHES REQUIRED FOR MITIGATION = 273 CALIPER INCHES EXISTING TREES TO BE SAVED THAT WILL COUNT TOWARDS MITIGATION ARE AS FOLLOWS: - (5) 12" CAL. ASH = 60" - (1) 18" CAL. ASH = 18" - (5) 4" CAL. MAPLE = 20" - (2) 6" CAL. MAPLE = 12" - (1) 8" CAL. MAPLE = 8" - (3) 12" CAL. MAPLE = 36" - (1) 15" CAL. MAPLE = 15" - (1) 10" CAL. CHOKE CHERRY = 10" - (1) 3" CAL. LINDEN = 3" - (1) 6" CAL. PEAR = 6" - (1) 12" CAL. SMOKE TREE = 12" - (1) 12" CAL. SPRUCE = 12" - (1) 18" CAL. PINE = 18" TOTAL CALIPER INCHES SAVED = 230 CALIPER INCHES 2. PER CITY CODE: UNDER UDC TITLE 11, CHAPTER 3, ARTICLE B: LANDSCAPING REQUIREMENTS. THE SUB HEADING 11-3B-10C.5 LISTS MITIGATION AS REQUIRED LANDSCAPING PER ARTICE B. WHERE ADDITIONALLY THE SUB HEADING 11-3B-10C.6 SPECIFICALLY STATES "Required Landscaping: Existing trees that are retained or relocated on site may count toward the required landscaping. Mitigation trees are in addition to all other landscaping required by this article." AS ALL TREES TO BE SAVED (LISTED ABOVE) ARE NOT UTILIZED TOWARDS ANY OTHER REQUIRED LANDSCAPING AS SHOWN ON SHEET L1.0 "LANDSCAPING REQUIREMENTS" THEY ARE TO BE UTILIZED FOR THE MITIGATION SPECIFIC LANDSCAPING REQUIREMENTS. AS STATED TO BE ALLOWED PER CITY CODES NOTED ABOVE. 3. THEREFORE THE METHOD OF MITIGATION WILL BE TO USE THE ADDITIONAL PROPOSED TREES AND EXISTING SAVED TREES TO MEET THE MITIGATION LANDSCAPING REQUIREMENTS. 3.1. PROPOSED TREES IN EXCESS OF LANDSCAPING REQUIREMENTS: (SEE SHEET L1.0) 31X 2" CAL. = 66 CAL. INCHES 3.2. EXISTING TREES TO BE SAVED OR RELOCATED: 24 @ (TOTAL CAL. INCHES AS NOTED ABOVE) = 230 CAL. INCHES 3.3. TOTAL MITIGATION CALIPER INCHES = 296 CAL. INCHES 4. NOTE: TREE REMOVAL SHOWN IS FOR WORST CASE SCENARIO. CONTRACTOR IS ENCOURAGED TO LOCATE BUILDING FOOTPRINTS, SIDEWALKS AND PATIOS TO MINIMIZE DISTURBANCE TO EXISTING LANDSCAPE. ADDITIONALLY, ALL TREES BOTH NOTED FOR REMOVAL AND RETENTION MAY BE RELOCATED ON SITE AS NOTED ON THIS SHEET. 5. NOTE: ALL TREES TO BE SAVED SHALL BE PROFESSIONALLY PRUNED BY A CERTIFIED ARBORIST. 6. SITE TREE ANALYSIS AND MITIGATION PLAN REVIEWED AND APPROVED PER CITY FORESTER ON 11/8/2021. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES Call before you dig. Know what's below . R South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. 2002 S. Vista Ave Boise, ID 83705 208.342.2999 Office info@sbbgo.com www.sbbgo.com All rights reserved. Reproduction or use in any form or by any means without written permission of South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. is unlawful and subject to criminal prosecution. No. Date Description THE PROFESSIONAL SERVICES OF THE DESIGN PROFESSIONAL ARE UNDERTAKEN FOR AND ARE PERFORMED IN THE INTEREST OF "THE CLIENT" NO CONTRACTUAL OBLIGATION IS ASSUMED BY THE DESIGN PROFESSIONAL FOR THE BENEFIT OF ANY OTHER PERSON INVOLVED IN THE PROJECT. F O S C A P E A R C H I T E C T D N A L D E S N E C I L LA - 276 E T A T S I D A H O G. M I J M I H A N 12/21/21 12/27/21 A-2021-0223