HomeMy WebLinkAbout08 WS CAT, Landscape Plan Sheet (3) V1ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
P/L P/L P/L P/L
P/L P/L P/L P/L P/L P/L
P/L P/L P/L P/L P/L P/L P/L
P/L P/L P/L
SAW
SAW SAW
SAW
1
2
2
EXISTING TREES TO
REMAIN
PLANTS TO BE
INSTALLED
CUT EDGE, SEE
DETAIL 2/L2.0
RTF TURF TYPE TALL
FESCUE SOD OVER
APPROVED TOPSOIL AS
SPECIFIED
SELECT MULCH IN
PLANTING BEDS OVER
APPROVED TOPSOIL AS
SPECIFIED.
EXISTING TURF TO BE
RETAINED AND
PROTECTED
LANDSCAPE TO BE
REMOVED.
LANDSCAPE LEGEND
EXISTING TREES TO
BE REMOVED
RELOCATE EXISTING MEMORIAL TREE
AND FLAG POLE PER OWNER.
NON-QUALIFYING TREE. DYING. DO
NOT SAVE. TO BE REMOVED.
MITIGATION DOES NOT APPLY.
CALLOUT LEGEND
1
2
L1.1
TREES NOTED SHALL BE REMOVED AND REPLACED WITH HYDRAULIC TREE SPADE. SPADE
SHALL HAVE A CAPACITY FOR A MINIMUM ROOT BALL DIAMETER AS NOTED AND A MINIMUM
ROOT BALL DEPTH AS NOTED. ONE FULL DAY BEFORE TRANSPLANT, ALL DECIDUOUS TREES
SHALL BE SPRAYED WITH AN ANTI-TRANSPIRANT (WILT-PRUF OR EQUAL) TO ALL OF THE
FOLIAGE (TOP AND BOTTOM) AS PER MANUFACTURER'S RECOMMENDATIONS. THE TREE
TRANSPLANT SHALL BE DONE IN ONE CONTINUOUS PROCESS AND THE PREVIOUSLY DUG
RECEIVING THE NEW LOCATION FILL. HOLE SIDES SHALL BE SCARIFIED. A PLANTING MIXTURE
OF ONE PART PEAT MOSS TO THREE PARTS TOPSOIL WITH AGRO 'TRANSPLANTER', 4-2-4 (OR
APPROVED EQUAL, USE AS PER MANUFACTURER'S RECOMMENDATIONS) SHALL BE MIXED
WITH WATER TO FORM A SLURRY. THE SLURRY MIXTURE SHALL FILL ANY VOIDS AROUND THE
ROOTBALL, ELIMINATING ANY AIR POCKETS. AGRIFORM PLANTING TABLETS 20-15-5 (OR
APPROVED EQUAL) SHALL BE INSTALLED. TABLET QUANTITY BASED UPON PLANT SIZE AS PER
MANUFACTURER'S RECOMMENDATIONS.
TREE SPADE SIZE DECIDUOUS TREE - TRUNK DIAMETER EVERGREEN TREE - HEIGHT
44 INCHES 2 TO 4 INCHES 5 TO 7 FEET
66 INCHES 4 TO 6 INCHES 7 TO 10 FEET
92 INCHES 6 TO 10 INCHES 12 TO 15 FEET
TRUNK DIAMETERS ARE MEASURED USING A CALIPER, SIX INCHES ABOVE THE GROUND FOR
TREE FOUR INCHES IN DIAMETER OR SMALLER AND 12 INCHES ABOVE THE GROUND FOR
TREES WITH A LARGE DIAMETER.
NOTE: THE INDUSTRY STANDARD IS 1:10. (10 INCHES OF ROOTBALL FOR EVERY INCH OF
TRUNK CALIPER)
TREE PROTECTION NOTES: TREE TRANSPLANT NOTES:
1. PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE
TREE) OF THE TREES TO REMAIN ON SITE BY:
a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT
ZONE OF THE TREE TO BE PROTECTED PRIOR TO DEMOLITION, CONSTRUCTION,
OR ANY SITE WORK.
b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR
DURING DEMOLITION.
c. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR
ANYWHERE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS.
SEE EROSION AND SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE
WASHOUT AREAS.
d. NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION
AREA.
e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER
AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE
ENTIRE AREA PER WEEK.
f. NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL
WITHIN THE CRITICAL ROOT ZONE.
g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING
TREE ROOTS.
2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY:
a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE
TRUNKS OR BRANCHES.
b. HAVING TREES PRUNED BY A LICENSED ARBORIST.
3. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION
SHALL BE MITIGATED USING THE MITIGATION STANDARDS AS SET FORTH IN THE
CURRENT CITY CODE.
TREE PROTECTION DETAIL
NOT TO SCALE
OUTLINE OF TREE CROWN (EDGE
OF DRIPLINE) CORRESPONDING
WITH ROOT SPREAD. FENCE SHALL BE
PLACED AT EDGE OF TREE CROWN
(MINIMUM DISTANCE).
EXISTING GRADE
NOTE:
MAINTAIN PROTECTION UNTIL
CONSTRUCTION ACTIVITIES ARE
COMPLETED.
IF LOWER LIMBS INTERFERE WITH WORK,
TIE UP WITH HEAVY JUTE CORD.
ADJUST DIAMETER OF PROTECTIVE FENCE
TO PREVENT ANTICIPATED DAMAGE BY
EQUIPMENT.
TREE TRUNK
CROWN OF TREE.
OUTLINE OF TREE CROWN (EDGE
OF DRIPLINE) CORRESPONDING
WITH ROOT SPREAD. FENCE SHALL BE
PLACED AT EDGE OF TREE CROWN
(MINIMUM DISTANCE).
SECTION
PLAN VIEW
TREE CROWN
FENCE LINE
#
W OVERLAND ROAD
TREE MITIGATION NOTES:
1. THE EXISTING TREES TO BE REMOVED THAT REQUIRE MITIGATION ARE AS FOLLOWS
FROM THE INTERIOR OF THE SITE (AS NOTED ON PLAN):
- (1) 4" CAL. MAPLE = 4"
- (4) 8" CAL. MAPLE = 32"
- (2) 6" CAL. CHOKECHERRY = 12"
- (5) 12" CAL. ASH = 60"
- (1) 12" CAL. MAPLE = 12"
- (2) 15" CAL. MAPLE = 30"
- (3) 11" CAL. ASH = 33"
- (1) 8" CAL. LINDEN = 8"
- (1) 12" CAL. LINDEN = 12"
- (1) 12" CAL. PINE = 12"
- (1) 18" CAL. PINE = 18"
- (2) 12" CAL. SPRUCE = 24"
- (1) 10" CAL. CHOKE CHERRY = 10"
- (1) 6" CAL. PEAR = 6"
TOTAL CALIPER INCHES REQUIRED
FOR MITIGATION = 273 CALIPER INCHES
EXISTING TREES TO BE SAVED THAT WILL COUNT TOWARDS MITIGATION ARE AS
FOLLOWS:
- (5) 12" CAL. ASH = 60"
- (1) 18" CAL. ASH = 18"
- (5) 4" CAL. MAPLE = 20"
- (2) 6" CAL. MAPLE = 12"
- (1) 8" CAL. MAPLE = 8"
- (3) 12" CAL. MAPLE = 36"
- (1) 15" CAL. MAPLE = 15"
- (1) 10" CAL. CHOKE CHERRY = 10"
- (1) 3" CAL. LINDEN = 3"
- (1) 6" CAL. PEAR = 6"
- (1) 12" CAL. SMOKE TREE = 12"
- (1) 12" CAL. SPRUCE = 12"
- (1) 18" CAL. PINE = 18"
TOTAL CALIPER INCHES SAVED = 230 CALIPER INCHES
2. PER CITY CODE: UNDER UDC TITLE 11, CHAPTER 3, ARTICLE B: LANDSCAPING
REQUIREMENTS. THE SUB HEADING 11-3B-10C.5 LISTS MITIGATION AS REQUIRED
LANDSCAPING PER ARTICE B. WHERE ADDITIONALLY THE SUB HEADING 11-3B-10C.6
SPECIFICALLY STATES "Required Landscaping: Existing trees that are retained or relocated on
site may count toward the required landscaping. Mitigation trees are in addition to all other
landscaping required by this article." AS ALL TREES TO BE SAVED (LISTED ABOVE) ARE NOT
UTILIZED TOWARDS ANY OTHER REQUIRED LANDSCAPING AS SHOWN ON SHEET L1.0
"LANDSCAPING REQUIREMENTS" THEY ARE TO BE UTILIZED FOR THE MITIGATION
SPECIFIC LANDSCAPING REQUIREMENTS. AS STATED TO BE ALLOWED PER CITY CODES
NOTED ABOVE.
3. THEREFORE THE METHOD OF MITIGATION WILL BE TO USE THE ADDITIONAL PROPOSED
TREES AND EXISTING SAVED TREES TO MEET THE MITIGATION LANDSCAPING
REQUIREMENTS.
3.1. PROPOSED TREES IN EXCESS OF LANDSCAPING REQUIREMENTS: (SEE SHEET L1.0)
31X 2" CAL. = 66 CAL. INCHES
3.2. EXISTING TREES TO BE SAVED OR RELOCATED: 24 @ (TOTAL CAL. INCHES AS NOTED
ABOVE) = 230 CAL. INCHES
3.3. TOTAL MITIGATION CALIPER INCHES = 296 CAL. INCHES
4. NOTE: TREE REMOVAL SHOWN IS FOR WORST CASE SCENARIO. CONTRACTOR IS
ENCOURAGED TO LOCATE BUILDING FOOTPRINTS, SIDEWALKS AND PATIOS TO MINIMIZE
DISTURBANCE TO EXISTING LANDSCAPE. ADDITIONALLY, ALL TREES BOTH NOTED FOR
REMOVAL AND RETENTION MAY BE RELOCATED ON SITE AS NOTED ON THIS SHEET.
5. NOTE: ALL TREES TO BE SAVED SHALL BE PROFESSIONALLY PRUNED BY A CERTIFIED
ARBORIST.
6. SITE TREE ANALYSIS AND MITIGATION PLAN REVIEWED AND APPROVED PER CITY
FORESTER ON 11/8/2021.
CALL 2 BUSINESS DAYS
IN ADVANCE BEFORE
YOU DIG, GRADE, OR
EXCAVATE FOR THE
MARKING OF
UNDERGROUND
MEMBER UTILITIES
Call before you dig.
Know what's below .
R
South Landscape Architecture P.C.
Dba South Beck & Baird Landscape Architecture P.C.
2002 S. Vista Ave
Boise, ID 83705
208.342.2999 Office
info@sbbgo.com
www.sbbgo.com
All rights reserved. Reproduction or use in any
form or by any means without written permission of
South Landscape Architecture P.C. Dba South
Beck & Baird Landscape Architecture P.C. is
unlawful and subject to criminal prosecution.
No. Date Description
THE PROFESSIONAL SERVICES OF THE DESIGN PROFESSIONAL ARE UNDERTAKEN FOR AND ARE PERFORMED IN THE INTEREST OF "THE CLIENT" NO CONTRACTUAL OBLIGATION IS ASSUMED BY THE DESIGN PROFESSIONAL
FOR THE BENEFIT OF ANY OTHER PERSON INVOLVED IN THE PROJECT.
F
O
S
C
A
P
E
A
R
C
H
I
T
E
C
T
D
N
A
L
D
E
S
N
E
C
I
L
LA - 276
E
T
A
T
S
I
D
A
H
O
G.
M
I
J
M
I
H
A
N
12/21/21
12/27/21
A-2021-0223