Loading...
HomeMy WebLinkAbout153-1A0018-L2.1 IRRIGATION PLAN V1E FO 20' Side Setback (z) 20' Front Setback (z) L1 E FO 20' Side Setback (z) 20' Front Setback (z) L1 E FO 20' Side Setback (z) 20' Front Setback (z) L1 TO-GO PARKING TO-GO PARKING TO-GO PARKI NG TO-GO PARKING TO-GO PARKING TO-GO PARKING CHINDEN BOULEVARD 8 8 8 8 8 8 8 8 8 3.0 3.0 3.0 3.0 2.0 2.0 1.0 1.0 1.0 1.0 .75 .75 .75 .75 01 D FS MV 1" 1" 1 1 4" 1 1 4" 1 1" 1 4" 1" 1" 1 1 4" 1" 8 8 8 8 1 2 1 2 8 1 7 1 7 1 5 1 7 1 5 1 5 1 7 1 5 1 7 1 5 1 5 1 7 1 7 1 5 1 5 3 4" 1 1 4" C RS 1" 1 1" 13.9 3 2 1" 10.5 1" 10.5 4 1" 13.9 5 1" 8.44 6 1" 8.45 7 1" 11.7 8 1" 9.50 9 1" 5.69 11 1" 15.1 10 1" 13.8 1 1 4" 1 1 4" 1 1 4" 1" 1" 1" Restaurant #: Issue Date: Drawing REVISION ARCHITECTS PROJECT Job # 1A0018 11-29-21 19G0026 OLIVE GARDEN P78DOM-L SEC CHINDEN BLVD. & LINDER RD. MERIDIAN ID, 83646 ACS Architectural acs-architects.com 101 Shipyard Way Suite B Newport Beach, CA 92663 T 714 436-9000 Construction Services Inc NPB MKE ATL CONSULTING ARCHITECT CAUTION: NOTICE TO CONTRACTOR THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF THE UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 111 East Broadway, Suite 600 Salt Lake City, UT 84111 Tel. No. (385) 212-3176 KHA PROJECT #093863001 NORTH IRRIGATION PLAN L2.1 NORTH EXISTING SIDEWALK PROPERTY LINE PROPERTY LINE PROPERTY LINE EXISTING EDGE OF PAVEMENT LA-16751 * * C H R I S T O P H E R M . R O S E S T A T E O F I D A H O L I C E N S E D L A N D S C A P E A R C H I T E C T 11/29/2021 UNLESS OTHERWISE SPECIFIED, THE AUTOMATIC SPRINKLER IRRIGATION SYSTEM LAYOUT AS SHOWN ON THE PLANS SHALL BE CONSIDERED SCHEMATIC. THE CONTRACTOR SHALL LAY OUT THE ENTIRE SYSTEM USING STAKES TO INDICATE THE LOCATION OF THE VARIOUS COMPONENTS. PRELIMINARY ADJUSTMENTS TO CONFORM TO ACTUAL SITE CONDITION SHALL BE ACCOMPLISHED AT THIS TIME AND THE APPROVAL OF THE ENGINEER OBTAINED PRIOR TO ANY ACTUAL WORK BEING PERFORMED. UTILITY CONNECTIONS, BOTH WATER AND ELECTRICAL, SHALL BE AS SHOWN ON THE PLANS OR AS DESIGNATED BY THE UTILITY CONCERNED. UNLESS SPECIFICALLY EXEMPTED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL PAY ALL COSTS CONCERNED IN PROVIDING THESE SERVICES. IRRIGATION DISCLAIMER CONTROLLER(S) SHALL BE LOCATED AT LOCATION SHOWN ON PLAN; FIELD VERIFY EXACT LOCATION WITH OWNER. POWER SUPPLY (AS REQUIRED BY SPECIFIED CONTROLLER) IS NOT WITHIN THE IRRIGATION CONTRACTOR'S SCOPE OF WORK, AND SHALL BE PROVIDED BY OTHERS. COORDINATE POWER SUPPLY WITH ELECTRIC PROVIDER AND GENERAL CONTRACTOR. HOOK-UP OF CONTROLLER TO PROVIDED POWER SUPPLY SHALL BE BY THE IRRIGATION CONTRACTOR. APPLICABLE SLEEVE PENETRATIONS THROUGH BUILDINGS / WALLS SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR. IRRIGATION CONTROLLER NOTE SLEEVES SHALL BE PROVIDED AND INSTALLED FOR ALL PIPING AND WIRING UNDER ROADWAYS, WALKWAYS, AND OTHER HARDSCAPE FEATURES GREATER THAN 24" IN WIDTH. SLEEVES FOR CONTROL WIRES SHALL BE 2" DIA. SCH 40 PVC AND CONTAIN NO MORE THAN 25 WIRES PER SLEEVE. FOR PLAN CLARITY, SLEEVE LOCATIONS AND SYMBOLS ARE REPRESENTATIVE AND DIAGRAMMATIC; COORDINATE SLEEVE LOCATIONS WITH GENERAL CONTRACTOR. IRRIGATION SLEEVING / WIRING NOTE TREE BUBBLER, TYP. PIPE & WIRE SLEEVING, TYP. CONTROLLER, SEE NOTE AREA FOR DRIPLINE, TYP. LAYOUT IS DIAGRAMMATIC, TYP. SEE DISCLAIMER BELOW POINT OF CONNECTION APPROXIMATE LOCATION - REFERENCE CIVIL UTILITY PLAN AND VERIFY LOCATION IN FIELD MANUAL DRAIN VALVE QUICK COUPLER VALVE MASTER VALVE FLOW SENSOR SLEEVING, TYP. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI Toro 570Z-6P-PC Adjustable Arc 31 30 Turf Spray, 6" Pop-Up, with a Zero Flush Seal. 1/2" Female-Threaded Inlet. Ideal for small to medium landscape areas. Toro 570S-FB-PC .25 38 30 Pressure-Compensating Flood Bubbler Nozzle on 570S Fixed Riser. 0.25GPM, 0.5GPM, 1.0GPM, and 2.0GPM. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI Toro MINI8-4P-CV 4 30 Turf Rotor, 4" Lawn Pop-Up. Stainless Steel Adjustment Screw. Part and Full Circle, 40-360 adjustable arc. With Check Valve. Toro MINI8-4P-CV 4 30 Turf Rotor, 4" Lawn Pop-Up. Stainless Steel Adjustment Screw. Part and Full Circle, 40-360 adjustable arc. With Check Valve. Toro MINI8-4P-CV 2 30 Turf Rotor, 4" Lawn Pop-Up. Stainless Steel Adjustment Screw. Part and Full Circle, 40-360 adjustable arc. With Check Valve. Toro MINI8-4P-CV 4 30 Turf Rotor, 4" Lawn Pop-Up. Stainless Steel Adjustment Screw. Part and Full Circle, 40-360 adjustable arc. With Check Valve. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Toro DZK-700 3 Low Flow Drip Control Valve Kit. With 1" Irritrol 700 UltraFlow Inline Valve, Toro Y-Filter, Pressure Regulator and Fittings. 0.10gpm-30gpm. Regulated pressure at 40psi Toro T-FCH-H-FIPT 1 Flush Valve, plumbed to flush manifold at low point; INSTALL ONE PER DRIP ZONE Toro T-YD-500-34 1 1/2" Air Vent- MIPT Air Release and Vacuum Relief Valve; INSTALL ONE PER DRIP ZONE, AT HIGHEST ELEVATION POINT Area to Receive Dripline Toro PCB-218 2,363 l.f. Drip-In Pressure Compensating Landscape Dripline. 0.53 GPH emitters at 18" O.C. Dripline laterals spaced at 18" apart, with emitters offset for triangular pattern. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Toro P220-26-0 GLOBE 8 Electric, 1", 1-1/2", 2" and 3" Plastic In-Line Remote Control Valve. Equipped to withstand pressure up to 220 PSI. Filter screen on 2" and 3" models. Standard Solenoid. Globe Body Style. Toro 100-SLVLC 1 One-Piece, 1" Single Lug Quick Coupler Valve with Vinyl Locking Cover. Isolation Ball Valve 1 Toro 220-26-9 1" 1 Brass 1", 1-1/4", 1-1/2", 2", 2-1/2", and 3" Master Valve. With DC Latching Solenoid. 1"-2" have In-Line Globe Body Style, and 2-1/2" - 3" are Angle Valve Body Styles. Manual Drain Valve 1 Toro TMC-424E-ID-F with (01) TSM-8 1 12-Station Indoor Controller. 4-Base Station Model with one 8-station expansion module. High-Surge, Flow-Sensing. Toro 53853 1 Wired Rain/Freeze Sensor. Mount as noted or approved, use controller power or optional transformer. Adjust rain shutoff index. Normally-Open or Normally-Closed. Compatible with most controllers. Toro TFS 1" 1 1/2", 3/4", 1", 1-1/2", 2", 3", and 4" Plastic Tee Sizes. Effective Flow Monitoring, even in flows less than 5 GPM. Compatible with TORO and competitive controllers. Impeller-based, PVC Design. Point of Connection 1" 1 Existing Pressurized Irrigation Line Irrigation Lateral Line: PVC Schedule 40 3,156 l.f. Irrigation Mainline: PVC Schedule 40 507.1 l.f. Pipe Sleeve: PVC Class 200 SDR 21 422.0 l.f. 8 10 12 15 8 1 0 1 2 1 5 25 50 10 20 .75 1.0 2.0 3.0 F A MV D C RS FS XX Valve Number Valve Flow Valve Size Valve Callout # #" # IRRIGATION SCHEDULE NUMBER MODEL SIZE TYPE GPM PSI @ POC PRECIP 1 Toro P220-26-0 GLOBE 1" Turf Rotary 13.95 38.96 0.61 in/h 2 Toro P220-26-0 GLOBE 1" Turf Rotor 10.50 39.51 0.44 in/h 3 Toro P220-26-0 GLOBE 1" Turf Rotor 10.50 40.44 0.45 in/h 4 Toro P220-26-0 GLOBE 1" Turf Rotary 13.93 37.57 0.62 in/h 5 Toro P220-26-0 GLOBE 1" Turf Rotary 8.44 37.66 0.75 in/h 6 Toro DZK-700 1" Area for Dripline 8.45 40.76 0.39 in/h 7 Toro P220-26-0 GLOBE 1" Turf Spray 11.67 38.97 2.37 in/h 8 Toro DZK-700 1" Bubbler 9.50 46.32 1.06 in/h 9 Toro DZK-700 1" Area for Dripline 5.69 37.63 0.39 in/h 10 Toro P220-26-0 GLOBE 1" Turf Spray 13.82 40.58 0.91 in/h 11 Toro P220-26-0 GLOBE 1" Turf Spray 15.11 41.37 0.87 in/h VALVE SCHEDULE Generated: 2021-11-29 10:11 P.O.C. NUMBER: 01 Water Source Information: Existing Pressurized Irrigation Line FLOW AVAILABLE Point of Connection Size: 1" Flow Available: 19.62 GPM PRESSURE AVAILABLE Static Pressure at POC: 65.00 PSI Pressure Available: 65.00 psi DESIGN ANALYSIS Maximum Station Flow: 15.11 GPM Flow Available at POC: 19.62 GPM Residual Flow Available: 4.51 GPM Critical Station: 8 Design Pressure: 30 PSI Friction Loss: 2.1 PSI Fittings Loss: 0.21 PSI Elevation Loss: 0 PSI Loss through Valve: 10.22 PSI Pressure Req. at Critical Station: 42.53 PSI Loss for Fittings: 0.12 PSI Loss for Main Line: 1.22 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 0 PSI Loss for Master Valve: 2.45 PSI Critical Station Pressure at POC: 46.32 PSI Pressure Available: 65 PSI Residual Pressure Available: 18.68 PSI CRITICAL ANALYSIS 12/14/21 A-2021-0227