4 3 2 1
A
B
C
D
E
A2
3
3
36' - 4 1/2" 5' - 2 1/8" 36' - 5 7/8" 5' - 2 1/8" 41' - 7 1/8" 5' - 2 1/8"
35' - 1 3/8" 8' - 7 1/4" 30' - 10 3/4"
7' - 1" 16' - 5 3/8"
11' - 3 1/2" 11' - 3 1/2" 23' - 5 7/8"
GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY LOCATION & SIZE OF ALL ROOF OPENINGS AND
EQUIPMENT PLATFORMS REQUIRED - SEE COORDINATION NOTES BELOW.
2. CONTRACTOR SHALL REFER TO PLUMBING, MECHANICAL AND REFRIGERATION
DRAWINGS FOR ALL VENTS AND PIPES THROUGH ROOF (WHICH MAY NOT
NECESSARILY BE SHOWN ON THIS ROOF PLAN)
3. ANY/ALL OPENINGS AT ROOF LARGER THAN 8"X8" SHALL BE PROTECTED WITH
BURGLAR BARS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. THE
SPACING OF BARS SHALL NOT EXCEED 5" O.C.
4. ALL PENETRATIONS THROUGH ROOFING SHALL BE WEATHERTIGHT. CONTRACTOR
SHALL BE RESPONSIBLE TO REVIEW WITH ROOFING INSTALLER AND ROOFING
MANUFACTURER PRIOR TO ANY REQUIRED OVERCUTS OR LAPS REQUIRED TO
PROVIDE WEATHERTIGHT AND WARRANTED SYSTEM. PROVIDE STANDARD ROOFING
MANUFACTURER BOOTS AND FLASHING FOR PENETRATIONS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A CERTIFICATE STATING THE
ANY/ALL ROOF INSTALLATION HAS BEEN APPLIED PER MANUFACTURER'S
RECOMMENDATIONS AND SPECIFICATIONS.
6. ALL NEW ROOFING MATERIAL MUST COMPLY WITH ENERGY CODE.
7. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SUBMITTALS
& SHOP DRAWINGS AND ALL NECESSARY COORDINATION WITH THE ROOFING
CONTRACTOR FOR THE FINAL PLACEMENT & SIZES OF THE ROOF CONDENSER
PLATFORMS, REFRIGERATION PIPING PENETRATION/CURBS, ROOF MOUNTED CURBS
FOR MECHANICAL (HVAC) EQUIPMENT, PLUMBING PIPING & STACK PENETRATIONS,
PIPING SUPPORTS, EXHAUST/MAKE-UP AIR VENTS, ETC.
8. SAID COORDINATION SHALL BE PREFORMED PRIOR TO ANY INSTALLATION OF
REQUIRED BLOCKING BELOW ROOF SHEATHING AS WELL AS ALL ROOF INSULATION
& MEMBRANE COMPONENTS TO BE INSTALLED BY THE CONTRACTOR'S ROOFING
SUB. CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY ATTACHMENTS,
PENETRATION SEALANTS, ETC. AS NEEDED FOR COMPLETION OF WORK.
9. THE CONTRACTOR IS TO PROVIDE MEMBRANE FLASHING & COUNTERFLASHING FOR
ALL MECHANICAL EQUIPMENT CURBS & VENTS.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR THE G.I. CAPS AND ATTACHMENTS AT
ALL PLATFORMS AND EQUIPMENT CURBS AS SHOWN IN DETAILS.
9 7/8" 2" 11"
REF. REFRIG 3"
12" MIN
10"x56" OPENING FOR
REFRIGERATION LINES. COORDINATE
LOCATION W/ REFRIGERATION
EQUIPMENT. FILL OPENING WITH
EXPAND FOAM SEALANT WHEN
WORK IS COMPLETE.
INSULATION (TYP)
MANUFACTURED CURB
FULLY ADHERED FLASHING
MEMBRANE EXTEND UP AND
OVER TOP OF CURB
TO COMPRESSOR RACK ENCLOSURE
(RE: REFRIG. DWGS) MOUNT TO
SUPPORT FRAME PER MFG.
REFRIGERATION CONTRACTOR
SHALL FILL OPENING W/
EXPANDED POAM SEALANT
WHEN WORK IS COMPLETE. REF
MEP FOR OPENING LOCATION
TAPER HOOD SLOPE 1/4" PER FT.
GALVANIZED METAL CAP W/
HOOD AT PIPE PENETRATIONS
VERTICAL REFRIGERATION LINES
MOUNTED TO UNISTRUT; UNISTRUT
TO BE ATTACHED TO CURB
#12x2" SS SCREWS WITH NEOPRENE/SS
BONDED WASHER AT 12" OC
FASTENER AND PLATE
CONT EDGE SEALANT IF
REQUIRED BY MFR
ROOF MEMBRANE
3"x3"x1/4" ANGLE. WELD TO TOP
CHORD OF JOIST WITH 1/8"x2"
FILLET WELD TYP. BOTH ENDS
VERTICAL VENT PIPES TO BE
ATTACHED TO ANGLE BY PIPE CLAMP
REF REFRIG
REF REFRIG
EXIST ROOF
SYSTEM AND
STEEL DECKING
EXIST JOIST
3"x3"x1/4" ANGLE
VENT PIPE STRAPS
ANCHOR
BRACKET
CONTINUOUS
SEALANT (TYP) OEPNING SIZE
VARIES, REF
REFRIGERATION FOR
SIZE AND LOCATION
2"
MIN
4"
6X SLEEPER, REF
STRUCTURAL
BUILD UP LOW SIDE
AS REQUIRED REF
STRUCTURAL
NEW CONDENSER
UNIT (SEE PLAN)
(E) JOIST, REF STRUCTURAL
CANT STRIP (TYP)
VERIFY EXACT SIZE SLEEPERS
NEEDED WITH REFRIGERATION
& HVAC CONTRACTORS.
FINISHED SLEEPERS TO BE
CONSTRUCTED LEVEL
NEW WATERPROOFING
UNDERLAYMENT (EPDM
MEMBRANE SELF ADHERING
MODIFIED BITUMEN)
NEW 20 GA. FLASHING PAN
(ALL SEAMS SOLDERED)
REF ROOFING MANUFACTURER FOR
FLASHING RECOMMENDATIONS AND
INSTALLATION DETAILS IN ORDER TO
PROVIDE A WEATHER-TIGHT SEAL BETWEEN
EXISTING ROOFING AND NEW WORK
TREATED WOOD
BLOCKING BOLTED TO
ROOF DECK. THICKNESS
TO MATCH ROOF
INSULATION
BASE FLASHING
FIBROUS CANT STRIP
SET IN BITUMEN
PRE-FABRICATED
ROOF CURB
EXHAUST FAN / OSA
INTAKE. REF
MECHANICAL FOR SIZE,
TYPE, & LOCATION
WOOD BLOCKING
#12x2" S/S SCREWS WITH
NEOPRENE/SS BONDED
WASHER AT 12" OC
EXISTING ROOFING
SYSTEM
SUPPORT FRAMING PER
STRUCTURAL
UNIT MOUNTING CURB BY
UNIT MANUFACTURER
RTU UNIT
FOR RTU ATTACHMENT
DETAILS - SEE STRUCTURAL
PATCH ROOFING AT NEW
CURB, CANT AND MEMBRANE
FLASHING INSTALLATION
NOT ISSUED FOR CONSTRUCTION
PROJECT TEAM
ISSUE/REVISION RECORD
PROFESSIONAL SEAL
PROFESSIONAL IN CHARGE
PROJECT MANAGER
QUALITY CONTROL
DRAWN BY
PROJECT NAME
PROJECT NUMBER
SHEET TITLE
SHEET NUMBER
COPYRIGHT NOTICE
www.greenbergfarrow.com
30 Executive Park
Suite 100
Irvine, CA 92614
t: 949 296 0450
Last Modified: Drawing Name:
This drawing is the property of the above
referenced Professional and is not to be
used for any purpose other than the
specific project and site names herein,
and cannot be reproduced in any manner
without the express written permission
from the Professional.
C:\Users\jchung\Documents\Grocery Outlet - Meridian, ID - Arch - R20_jchungKT98W.rvt
1 2/6/2021 1 0:00:32
AM
D. COUPER
C. NOWICKI
C. NOWICKI
J. CHUNG
GROCERY
OUTLET
2021 0671 .0
A104
ROOF PLAN
3503 N. EAGLE ROAD,
MERIDIAN, IDAHO 83646
1 ROOF 1/8" = 1'-PLAN 0" NORTH
KEYNOTES - ROOF PLAN
MARK NOTE
1 NEW TPO ROOF PER SPECIFICATIONS
2 PENETRATION FOR REFRIGERATION LINES, WITH WEATHER CAP - PER
R-SHEETS
3 AIR HANDLING UNIT - SEE M-SHEETS
4 HVAC CONDENSING UNIT SET ON CURB. SEE M-SHEETS
5 LEVEL CURB W/ DX PIPE THROUGH ROOF - SEE - M-SHEETS
6 ROOF HATCH PER SPECIFICATIONS
2 REFRIGERATION 1" = 1'-0" LINE ROOF PENETRATION
4 CONDENSER 1" = 1'-0" UNIT FLASHING
3 EXHAUST 1" = 1'-0" / OSA CURB
5 RTU 1" = 1'-CURB 0"
DATE DESCRIPTION
1 1 /1 8/2021 PERMIT SET
12/13/21
A-2021-0229