Loading...
HomeMy WebLinkAboutElevations 3 V1A114 13 14 15 16 4 A116 2 3 1 A105 2 A105 1 1 2 3 4 6 5 7 A114 9 10 11 12 4 3 2 1 A B C D E SALES FLOOR 101 FRONT OFFICE 102 BACK OFFICE 103 VESTIBULE 100 FREEZER 106 BREAK ROOM 107 STOCK ROOM 112 RESTROOM #1 109 RESTROOM #2 108 DAIRY COOLER 104 STOCK ROOM 111 ADJACENT TENANT SPACE (N.I.C.) ADJACENT TENANT SPACE (N.I.C.) 35' - 3 3/8" 39' - 11 5/8" 35' - 5" 42' - 2 1/4" 41' - 8" 41' - 7 1/4" 20' - 0" 17' - 10 5/8" 110' - 8" 163' - 4 1/8" 101A 100 102 103 108 109 112 101B 112A 106 104 111B 111C 111D 20' - 3 1/4" 3' - 7" 8' - 11 3/4" HOLD 24' - 3 1/4" 26' - 1" 10' - 6 1/2" 3' - 10 7/8" 44' - 7 3/8" 9' - 2 7/8" VERIFY WITH SHOP DRAWINGS 26' - 10" 20' - 0 3/4" 3' - 11 1/8" GAP 6" VERIFY WITH SHOP DRAWINGS 35' - 6" VERIFY WITH SHOP DRAWINGS 23' - 8 5/8" 18' - 10" GAP 6" VERIFY WITH SHOP DWG 19' - 3" GAP 6" 18' - 0" 83' - 2" W1A W1A W1 W1A W1 W1 111A VERIFY WITH SHOP DWG 25' - 2 5/8" VERIFY WITH SHOP DWG 18' - 6" VERIFY WITH SHOP DWG 12' - 1" 24' - 1" GAP 6" VERIFY WITH SHOP DWG 16' - 6" MEAT COOLER 105 105 A2 A105 3 AT EQUIPMENT PLATFORM 20' - 0" 6' - 8" 11' - 0 5/8" 12' - 3 1/2" 36' - 5 3/8" 7' - 11 1/2" 7' - 8 3/8" 6' - 8 5/8" 15' - 4 1/2" 3' - 3 3/4" 51' - 8 1/4" 3' - 3 3/4" 22' - 4 1/2" 3' - 0" 52' - 2" 25' - 6 3/8" 8' - 3 1/4" 36' - 7 1/8" 2' - 4 5/8" 113 8 8 8 8 16' - 0" 1' - 11 3/8" 2' - 1" 16' - 0" 9 9 24 A118 GENERAL NOTES 1. CHECKSTAND AND REFRIGERATION CASES SHOWN IN THIS PLAN FOR OVERALL COORDINATION & VERIFICATIONS - ALSO SEE FIXTURE LAYOUT DIMENSIONS ON SHEET A104 2. G.C. IS RESPONSIBLE TO PROVIDE CLIMATE AND SOUND INSULATION AT INTERIOR DEMISING AND PARTITION WALLS AS NOTED ON WALL LEGEND/TYPES. 3. SHELL G.C. MAY EITHER LEAVE UNDERSIDE OF ROOF STRUCTURE EXPOSED AND UNPAINTED BY PROVIDING "CLEAN" AND QUALITY" CRAFTSMANSHIP ACCEPTABLE TO THE TENANT REPRESENTATIVE - OR THEY WILL BE REQUIRED TO PAINT EXPOSED FRAMING AS WELL AS PROVIDE VINYL FACED SCRIM SHEET AT UNDERSIDE OF ROOF PLYWOOD AT ALL SALES AREAS. 4. DIMENSIONS FOR EXTERIOR FRAMING ARE TO FACE OF PLYWOOD AND/OR FACE OF MASONRY AS APPLIES (U.N.O) 5. G.C. TO PROVIDE INTERNATIONAL SYMBOL ACCESSIBILITY (ISA) DECAL AT MAIN ENTRANCE DOORS (UNDER SHELL WORK). 6. G.C. TO PROVIDE TACTILE EXIT SIGNS AT ALL GRADE LEVEL EXIT DOORS. SIGN TO READ "EXIT" - SEE DETAILS 7. G.C. TO PROVIDE FIRE DEPARTMENT KEY KNOX BOX. G.C. SHALL COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH LOCAL FIRE MARSHAL. 8. G.C. TO HOLD ALL UTILITY LINES TIGHT TO ROOF FRAMING OR PERIMETER WALLS. GOI WILL NOT ALLOW UNDERSLAB CONDUITS UNLESS PRIOR WRITTEN APPROVAL. 9. G.C. SHALL SEAL ALL PENETRATIONS AT EXTERIOR WALLS. THIS INCLUDES DOORS AND DOCK APPARATUS SO THAT VERMIN CANNOT ENTER BUILDING WHEN COMPLETELY CLOSED DOWN. 10. IT IS THE DESIGN INTENTION AND PREFERENCE TO EXPOSE WHERE PRACTICAL ANY LOW VOLTAGE + POWER CONDUITS + LIGHTING CONDUITS + GAS & WATER PIPING + SPRINKLING SYSTEM + REFRIGERATION LINE-SETS + CONDENSATE EVAC PIPING + SECURITY IN THE SALES AREAS AND BACK-OF-HOUSE FOR MAINTENANCE ACCESS AND POSSIBLE FUTURE REMODELING. 11. EXTERIOR BUILDING LIGHTING IS UNDER SHELL WORK AND SHALL BE PROVIDED AS FURTHER DEFINED IN THE VENDOR LIGHTING SHEETS AS WELL AS ELECTRICAL DRAWINGS. 12. G.C. SHALL PROVIDE ALL EMERGENCY/EXIT LIGHTING. 13. ILLUMINATED BUILDING IDENTIFICATION (ADDRESS) TO BE PROVIDED UNDER SHELL WORK PER LOCATION(S) SHOWN ON EXTERIOR ELEVATIONS. MUST BE SPECIFICALLY REVIEWED AND APPROVED WITH PLANNING / BUILDING / FIRE DEPARTMENT FOR FINAL LOCATION AND/OR TYPE DURING PROJECT SUBMITTALS. = SHELL STRUCTURAL WALLS (8" CMU) = BEARING / SHEAR WALLS (2X6 STUDS U.N.O) = T.I. FULL HT. (6" MTL. STUDS) = T.I. PARTITIONS (4" MTL. STUDS) = T.I. COOLER WALLS (MANUF.) WALL LEGEND SEE SHEET A119 FOR WALL TYPES AND INSULATION/FINISHES NOT ISSUED FOR CONSTRUCTION PROJECT TEAM ISSUE/REVISION RECORD PROFESSIONAL SEAL PROFESSIONAL IN CHARGE PROJECT MANAGER QUALITY CONTROL DRAWN BY PROJECT NAME PROJECT NUMBER SHEET TITLE SHEET NUMBER COPYRIGHT NOTICE www.greenbergfarrow.com 30 Executive Park Suite 100 Irvine, CA 92614 t: 949 296 0450 Last Modified: Drawing Name: This drawing is the property of the above referenced Professional and is not to be used for any purpose other than the specific project and site names herein, and cannot be reproduced in any manner without the express written permission from the Professional. C:\Users\jchung\Documents\Grocery Outlet - Meridian, ID - Arch - R20_jchungKT98W.rvt 1 1 /22/2021 1 2:49:59 PM D. COUPER C. NOWICKI C. NOWICKI J. CHUNG GROCERY OUTLET 2021 0671 .0 A101 FLOOR PLAN 3503 N. EAGLE ROAD, MERIDIAN, IDAHO 83646 1 OVERALL 1/8" = 1'-0" WALL DIMENSIONING PLAN NORTH KEYNOTES - FLOOR PLAN MARK NOTE 1 INSULATED CONCRETE SLAB WITH VAPOR BARRIER - SEE S-SHEETS 2 PLATFORM ACCESS LADDER 3 ELECTRICAL EQUIPMENT - SEE E-SHEETS 4 PLUMBING EQUIPMENT - SEE P-SHEETS 5 CURTAINWALL ABOVE DAIRY BOX FROM FACE OF CMU TO EDGE OF DEMISING WALL 6 EXISTING FIRE RISER TO REMAIN 7 SEE A102 FOR ADDITIONAL INFORMATION ON ALL FIXTURES 8 EXISTING PERIMETER WALLS TO REMAIN. RESTORE, SAND, AND PREPARE FOR NEW PAINT 9 INFILL STOREFRONT OPENING TO MATCH EXISTING SURFACES. NEW STOREFRONT ABOVE NEW KNEE WALL. SEE ELEVATIONS AND S SHEETS DATE DESCRIPTION 1 1 /1 8/2021 PERMIT SET 12/13/21 A-2021-0229