Loading...
HomeMy WebLinkAboutNarrative V11 9 9 N . C a p I t o l B l v d . S u I t e 6 0 2 B o I s e , I D 8 3 7 0 2 v . 2 0 8 . 3 3 8 . 1 4 1 3 f . 2 0 8 . 3 3 6 . 0 3 7 1 September 30, 2021 City of Meridian Planning Division 33 East Broadway Ave, Suite 102 Meridian, Idaho 83642 Re: Design Review and Certificate of Zoning Compliance Applications for the increased Warehouse area at 2810 East Franklin Road, Meridian. To Whom It May Concern: The attached Design Review and Certificate of Zoning Compliance documents are for the increased daylight basement (warehouse) area in the Office & Warehouse Flex Space Building, at 2810 East Franklin Road, previously approved CZC & DES A-2021-0026. The existing initial structure to be renovated and the new addition of daylight basement warehouse previously approved are to remain the same in size with the change of an increase of the daylight basement of 924 s.f. for a total of 7,488 s.f. of building area. The office area is 3,945 s.f. (53% of total building area) and the warehouse is 3,543 s.f (47% of total building area). The project site is 37,766 s.f. (0.87 acres), and the improvements will include paving, concrete slabs and sidewalks, and landscaping. Site Access – No change being proposed from CZC & DES A-2021-0026. Pedestrian Walks – No change being proposed from CZC & DES A-2021-0026. Building Orientation and Layout – The proposed area increase of the daylight basement is located on the Eastern portion of the daylight basement (warehouse). Parking – The parking lot spaces have been increased by one for a total of 14 parking spaces, including two accessible spaces, one near the main entry and the other on the north near the addition. The main parking areas are located on the northern portion of the site including the additional space and are screened from East Franklin Road by the existing building and addition. Parking spaces are broken up with landscape, a concrete masonry trash enclosure is located in the northwestern portion of the developed area, and is integrated into the lot and the surrounding landscape areas. Landscaping - The proposed site has been reduced by approximately three percent for a total of 20,410 s.f. of landscaping, totaling about 54 percent of the site. The reduction of landscape is due to the increase of the daylight basement and the additional parking space. Landscaping will be a mix of lawn areas, planters with trees and shrubs, and existing vegetation conditions to remain on the outmost norther part of the site. See attached Landscape Plan. Architectural Character – No change being proposed from CZC & DES A-2021-0026. Facades – No change to the South and West Elevations. The East elevation an additional window has been added. The main changes occurred in the North elevation with the elongation of the façade to the east portion of the site. Primary Entrance - No change being proposed from CZC & DES A-2021-0026. Roof Lines - No change being proposed from CZC & DES A-2021-0026. Color & Texture Variations- See attached exterior building elevations. Mechanical Equipment - No change being proposed from CZC & DES A-2021-0026. 11/10/21 A-2021-0198 1 9 9 N . C a p I t o l B l v d . S u I t e 6 0 2 B o I s e , I D 8 3 7 0 2 v . 2 0 8 . 3 3 8 . 1 4 1 3 f . 2 0 8 . 3 3 6 . 0 3 7 1 Materials - No change being proposed from CZC & DES A-2021-0026. Signs and Lighting - The building as proposed will have a main sign above the entry; see attached elevations for location and approximate size. The area adjacent to the building will be lit with wall mounted and recessed (at main entrance) exterior LED fixtures. See attached Site Photometric Plan for fixture types, location and site photometric readings. Please contact our office at 208-338-1413 if you have any questions or need further information. Thank you for your time regarding this matter. Thank You, David Blodgett, Architect Rudeen and Associates 11/10/21 A-2021-0198