HomeMy WebLinkAboutLandscape PlanRI
S
E
R
T
E
L
ECONCONCONCONCONCONCONCONCONCONCONCON
T T T T TTTTT TTTTTTTTTTTTELEC ELEC ELEC ELEC
KEY NOTES
PROTECT EXISTING TREE IN PLACE.
SEE CIVIL FOR DETENSION BASIN ROCK REQUIREMENTS.
EXISTING UTILITY, SEE CIVIL FOR MORE INFORMATION.
1
01SITE LANDSCAPE PLAN
SCALE: 1" = 30'-0"
15'30'60'
1.SEE SHEET EM-G-0002 FOR GENERAL CONSTRUCTION NOTES
2.ALL LANDSCAPE AND PLANT MATERIALS SHALL BE IN ACCORDANCE
WITH THE LATEST EDITION OF THE AMERICAN STANDARDS FOR
NURSERY STOCK, ANSI Z60.1. PROVIDE HEALTHY PLANT MATERIALS
AS SPECIFIED.
3.GRADING SHALL BE ACCEPTED PRIOR TO PLANT INSTALLATION.
CONTRACTOR SHALL AMEND PLANT BED SOIL AND SHAPE GRADES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL
DEBRIS AND EXCESS SOIL OCCASIONED BY THIS PROJECT IN THE
PLANT BED AREA.
4.PRIOR TO PLANTING, IRRIGATION SYSTEM SHALL BE FULLY
OPERATIONAL. CONTRACTOR SHALL INSTALL IRRIGATION SYSTEM TO
PROVIDE A COMPLETE SYSTEM WITH UNIFORM COVER TO ALL NEW
PLANTINGS. THOROUGHLY WATER ALL PLANTED AREAS IMMEDIATELY
AFTER PLANTING.
5.ADJUST PLANTING LOCATIONS IF THEY CONFLICT WITH EXISTING
UTILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR UTILITY
LOCATIONS AND PROTECTION DURING INSTALLATION OF PLANT
MATERIALS AND IRRIGATION SYSTEM.
6.REFER TO ENGINEERING DRAWINGS FOR FURTHER INFORMATION
REGARDING CIVIL MATTERS.
7.DISCREPANCIES BETWEEN PLANS AND SITE CONDITIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE OWNER PRIOR TO
PROCEEDING.
GENERAL NOTES
LANDSCAPE PLANEM-L-1001
0
CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD:
ENG. COORD:
OWNER:
DRAWN BY:
LID:
TOOL ETI:
TOOL MICAP:
NOTE
THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC.
AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY
A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY
THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED
DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY.
ISSUED FOR CONSTRUCTION
SIGNATURE
REVISION
SHEET
PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER
PCHRISTENSEN
JFIESELMAN
APPROVED FOR CONSTRUCTION
(APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/2020PLANT LEGEND
SYMBOL COMMON NAME BOTANICAL NAMEQUANTITY
LANDSCAPE LEGEND
SYMBOL DESCRIPTION NOTESQUANTITY
13,500 SQUARE FEET
DECORATIVE ROCK
COLOR: BLACK AND TAN
SIZE: 1" - 1 1
2" (NO FINES)
12
19
8
4
6
CANADA RED CHOKECHERRY
HOT WINGS TATARIAN MAPLE
CRIMSON SPIRE OAK
VANDERWOLF'S PYRAMID LIMBER PINE
SKYROCKET JUNIPER
SIZE
2" CALIPER
SINGLE STEM
2" CALIPER
SINGLE STEM
2" CALIPER
6' HEIGHT
6' HEIGHT
1
TREE QUANTITY
WEST PROPERTY LINE
145' LENGTH
4 TREES REQUIRED
4 TREES PROVIDED
SOUTH PROPERTY LINE
645' LENGTH
18 TREES REQUIRED
18 TREES PROVIDED (INCLUDES EXISTING TREE)
EAST PROPERTY LINE
145' LENGTH
4 TREES REQUIRED
4 TREES PROVIDED
PARKING LOT ISLANDS
24 TREES REQUIRED (2 PER ISLAND SERVING
DOUBLE PARKING STALLS)
24 TREES PROVIDED
57
52
SUMMER WINE NINEBARK
WINE & ROSES WEIGELA
2 GALLON CONTAINER
2 GALLON CONTAINER
TREE
SHRUB
3" DEPTH
PROPERTY LINE BUFFER & PARKING ISLANDS
CITY OF MERIDIAN LANDSCAPE
BUFFER (PARKING LOT)
REQUIREMENTS
SHRUB QUANTITY
AS NEEDED TO PROVIDE 70% COVERAGE AT
MATURITY IN REQUIRED LANDSCAPE PARKING
LOT AND BUFFER AREAS
PRUNUS VIRGINIANA 'CANADA RED'
ACER TATARICUM 'HOT WINGS'
QUERCUS ROBUR X ALBA 'CRIMSHMIDT'
PINUS FLEXIS 'VANDERWOLF'S PYRAMID'
JUNIPERUS SCOPULORUM 'SKYROCKET'
PHYSOCARPUS OPULIFOLIUS 'SEWARD'
WEIGELA FLORIDA 'ALEXANDRA'
NOTES
PRUNE TO MINIMUM CLEAR BRANCH
HEIGHT OF 6' AT INSTALL.
PRUNE TO MINIMUM CLEAR BRANCH
HEIGHT OF 8' AT MATURITY
PRUNE TO MINIMUM CLEAR BRANCH
HEIGHT OF 6' AT INSTALL.
PRUNE TO MINIMUM CLEAR BRANCH
HEIGHT OF 8' AT MATURITY
GROUNDCOVER
48 PANCHITO MANZANITA 2 GALLON CONTAINERARCTOSTAPHYLOS X
COLORADENSIS ' PANCHITO'
2
2
2
3
3
X
5' TYP. BUFFER
A.C.A.C.A.C.
ELEC ELEC ELEC ELEC
0.771
1"
1.302
1"
0.873
1"
1.324
1"
EC
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
SHRUB IRRIGATOR ASSEMBLY
(2) 0.5 GPH DRIP EMITTERS PER SHRUB 157
TREE IRRIGATOR ASSEMBLY
(4) 0.5 GPH DRIP EMITTERS 49
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
RAIN BIRD PESB VALVE 1". LOW FLOW
OPERATING CAPABILITY, GLOBE
CONFIGURATION, SCRUBBER
TECHNOLOGY, AND INLINE FILTER.
4
EXISTING BACKFLOW PREVENTER
(FEBCO 825Y) 1"
EXISTING REDUCED PRESSURE
BACKFLOW PREVENTER
-
RAIN BIRD ESP8LXME-LXMM
8 STATION CAPABLE COMMERCIAL
CONTROLLER. MOUNTED ON A POWDER
COATED GRAY METAL CABINET.
1
EXISTING POINT OF CONNECTION 3/4"-
IRRIGATION LATERAL LINE: PVC CLASS
200 SDR 21
4,450
L.F.
IRRIGATION MAINLINE: PVC SCHEDULE 40
CONTROL WIRE CONDUIT: PVC SCHEDULE 40
300
L.F.
PIPE SLEEVE: PVC SCHEDULE 40
WIRE SLEEVE: PVC SCHEDULE 40
550
L.F.
EACH
AIR RELIEF VALVE
SEE DETAIL
MANUAL DRAIN VALVE
SEE DETAIL
4
4
IRRIGATION SCHEDULE
EXISTING MAINLINE -
1,100
L.F.
EC EXISTING CONTROLLER -
01SITE IRRIGATION PLAN
SCALE: 1" = 30'-0"
15'30'60'
KEY NOTES
CONNECT TO EXISTING MAINLINE
INSTALL NEW CONTROLLER ADJACENT TO THE EXISTING
CONTROLLER.
APPROXIMATE EXISTING CONTROLLER LOCATION.
APPROXIMATE EXISTING MAINLINE.
EXISTING P.O.C. AND BACKFLOW ASSEMBLY.
NEW CONTROL WIRE FROM NEW CONTROLLER TO
FOLLOW EXISTING MAINLINE.
PROTECT EXISTING TREE.
1
1.SEE SHEET EM-G-0002 FOR GENERAL CONSTRUCTION NOTES.
2.CONTRACTOR TO VERIFY EXISTING IRRIGATION SYSTEM LAYOUT,
PRESSURES, AND FLOW. NOTIFY OWNER IF DISCREPANCY FOUND.
3.EXISTING IRRIGATION MANUFACTURER AND SIZES PROVIDED BY
OWNER - SEE TABLE.
4.THE PROPOSED IRRIGATION DESIGN ASSUMES THE EXISTING
MAINLINE IS LOCATED NEAR THE SOUTH END OF THE BUILDING ON
BOTH SIDES FOR A NEW MAINLINE CONNECTION.
5.SIZE IRRIGATION PIPES TO RESTRICT WATER FLOW TO A MAXIMUM OF
5 FEET PER SECOND.
6.CONTRACTOR TO LOCATE UTILITIES PRIOR TO DIGGING.
7.NO ROCKS, BOULDERS, OR OTHER EXTRANEOUS MATERIALS TO BE
USED IN BACKFILLING OF TRENCHES.
8.ALL PIPE AND PIPE CONNECTIONS TO BE INSTALLED AS PER
MANUFACTURER'S SPECIFICATIONS.
9.ALL EQUIPMENT NOT SPECIFIED ON THE LEGEND SHALL BE
DETERMINED, SUBMITTED IN SHOP DRAWING SUBMITTALS, AND
FURNISHED BY THE CONTRACTOR.
10.VALVE CONTROL WIRES SHALL BE COLOR CODED; COMMON-WHITE,
CONTROL-RED.
11.IRRIGATION DESIGN SHOWN ON THIS PLAN IS SCHMEMATIC. PLACE
ALL IRRIGATION EQUIPMENT WITHIN PLANTER BEDS.
GENERAL NOTES
SITE IRRIGATION PLANEM-L-1002
0
CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD:
ENG. COORD:
OWNER:
DRAWN BY:
LID:
TOOL ETI:
TOOL MICAP:
NOTE
THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC.
AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY
A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY
THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED
DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY.
ISSUED FOR CONSTRUCTION
SIGNATURE
REVISION
SHEET
PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER
PCHRISTENSEN
JFIESELMAN
APPROVED FOR CONSTRUCTION
(APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/20201
1
2
2
3
3
4
4
6
4
6
5
4
5
6
7
X
7
MAINLINE: 1" SCHEDULE 40 PVC
LATERALS: CLASS 200
WATER METER: 3/4" SIZE
STATIC PSI: 40 PSI
BACKFLOW PREVENTER: WILKINS 1 1/2"
CONTROLLER: LOCATED AT NORTH SIDE
OF BUILDING
VALVE OPERATION: ONE VALVE AT A TIME
EXISTING
IRRIGATION
ASSUMPTIONS
PLANTING DETAILSEM-L-3001
0
CARIZMENDEZREVDESCRIPTIONDATEBOISEFACILITIESENGINEERINGPROJECT COORD:
ENG. COORD:
OWNER:
DRAWN BY:
LID:
TOOL ETI:
TOOL MICAP:
NOTE
THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC.
AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY
A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY
THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED
DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY.
ISSUED FOR CONSTRUCTION
SIGNATURE
REVISION
SHEET
PROJECT / WO:DOCUMENTPROJECTC39982 CRUCIAL EXTERIOR MODIFICATIONS - FINISHED GOODS TO R&D SUPPORT SSCHELLER
PCHRISTENSEN
JFIESELMAN
APPROVED FOR CONSTRUCTION
(APPROVER)(DATE)0ISSUE FOR CONSTRUCTION2/6/2020A99% BID SET1/24/2020SCALE: NONE
6TREE PLANTING
SCALE: NONE
3SHRUB PLANTING
WOOD STAKES
DO NOT DRIVE INTO ROOTBALL
REMOVE AT END OF PLANT
ESTABLISHMENT PERIOD.
RAINWATER BASIN
FORMED AS 4"-6" DEPTH
DEPRESSION AROUND TREE
EXISTING GRADE
FLOW
TOPSOIL
DO NOT INSTALL ROOTBOUND
PLANTS.
PULL MULCH MATERIAL AWAY FROM
TRUNK
3" DEPTH DECORATIVE ROCK
GENTLY LOOSEN ROOTS AROUND
EXTERIOR OF ROOTBALL..
SET ROOTBALL ON UNDISTURBED
OR FIRMLY PACKED SOIL
PLANTING PIT 5' MIN. DIAMETER
FLOW
PLANTING PIT. 24" MIN. DIAMETER
18" MIN.
PULL MULCH MATERIAL AWAY
FROM TRUNK
3" DEPTH DECORATIVE ROCK MULCH
SIDES OF PIT SHALL BE RAKED TO
LOOSEN PRIOR TO SETTING
PLANTS IN PLACE
GENTLY LOOSEN ROOTS AROUND
EXTERIOR OF ROOTBALL. DO NOT PRUNE
PLANTS WITHOUT LANDSCAPE ARCHITECT
APPROVAL DIRECTION.
SET ROOTBALL ON UNDISTURBED OR FIRMLY
PACKED SOIL
DO NOT INSTALL ROOTBOUND PLANS
TOPSOIL
RAINWATER BASIN FORMED
AS 4"-6" DEPTH DEPRESSION
AROUND SHRUB
SIDES OF PIT SHALL BE
RAKED TO LOOSEN PRIOR TO
SETTING PLANTS IN PLACE
8.5" X 11" SIGN
LAMINATED IN PLASTIC
SPACED EVERY 50'
ALONG THE FENCE
4'-0"TREE PROTECTION FENCE: HIGH DENSITY
POLYETHYLENE FENCING WITH 3.5" X 1.5"
OPENINGS; COLOR-ORANGE. STEEL POSTS
INSTALLED AT 8' O.C.
2" X 6' STEEL POSTS OR APPROVED EQUAL
5" THICK LAYER OF ORGANIC MULCH
MAINTAIN EXISTING GRADE WITH THE
TREE PROTECTION FENCE UNLESS
OTHERWISE INDICATED ON THE PLANS
KEEP OUT
TREE
PROTECTION
AREA
CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA.
NOTES:
1.NO PRUNING SHALL BE PERFORMED EXCEPT BY
APPROVED ARBORIST.
2.NO EQUIPMENT SHALL OPERATE INSIDE THE
PROTECTIVE FENCING INCLUDING DURING FENCE
INSTALLATION AND REMOVAL.
3.DEEP WATER TREE PRIOR TO FENCE INSTALLATION.
WATER AS NECESSARY DURING CONSTRUCTION.
SCALE: NONE
2TREE PROTECTIONFENCING
CURB
18" DEEP LINEAR ROOT
BARRIER. (SEE
SPECIFICATIONS).
TAMP SOIL ADJACENT TO
ROOT BARRIERS TO
STABILIZE.
8' MIN.
TOP OF ROOT BARRIER FLUSH
WITH FINISHED GRADE.
CURB
FINISHED GRADE 2" BELOW
ADJACENT PAVEMENT
EXISTING SOIL
PLAN VIEW
18" DEEP LINEAR
ROOT BARRIER
NOTES:
1.ROOT BARRIERS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS
AND RECOMMENDATIONS.
SCALE: NONE
1ROOT BARRIERS -PARKING LOT ISLANDS
SCALE: NONE
5
TREE PLANTING -
WOOD STAKES
DO NOT DRIVE INTO ROOTBALL
REMOVE AT END OF PLANT
ESTABLISHMENT PERIOD.
CURB
TOPSOIL
DO NOT INSTALL ROOTBOUND
PLANTS.
PULL MULCH MATERIAL AWAY FROM
TRUNK
3" DEPTH DECORATIVE ROCK
MULCH
GENTLY LOOSEN ROOTS AROUND
EXTERIOR OF ROOTBALL..
SET ROOTBALL ON UNDISTURBED
OR FIRMLY PACKED SOIL
PLANTING PIT 5' MIN. DIAMETER
24" MIN.
SIDES OF PIT SHALL BE
RAKED TO LOOSEN PRIOR TO
SETTING PLANTS IN PLACE
PARKING ISLAND
CURB
FENCE3" DEPTH DECORATIVE ROCK MULCH
24" MIN.
TREE STAKES PLACED 2"
BELOW SURFACE
SUBGRADE UNDER ROOTBALL TO BE
KEPT UNDISTURBED TO REDUCE
SETTLING OR COMPACT TOPSOIL TO
PROVIDE A FIRM BASE TO PREVENT
SETTLEMENT1/2 HEIGHT OF TREEREMOVE WIRE BASKET
AND/OR BURLAP
COMPLETELY
GUY WIRE
SCALE: NONE
4
TREE PLANTING -EVERGREEN TREE
AT TIME OF PLANTING TRIM ONLY DEAD,
BROKEN AND DOUBLE LEADER
BRANCHES
REMOVE ALL TREE WRAP
FLAGGING 10" SQ MIN.
ROOT FLARE SHALL BE 1" TO 2" ABOVE FINISH
GRADE. REMOVE EXCESS SOIL FROM ROOT BALL
AS REQUIRED TO EXPOSE ORIGINAL ROOT FLARE
3" DEPTH DECORATIVE ROCK MULCH -
KEEP BACK FROM TRUNK
BACKFILL WITH TOP SOIL -
WATER IN 6" LAYERS, DO
NOT TAMP
PLANTING PIT 5' MIN. DIAMETER