HomeMy WebLinkAboutEM-L-3001nA
w
w
ry
LL
0
c�
w
(V
NOT USED
SCALE: NONE
GUY WIRE
REMOVE WIRE BASKET
AND/OR BURLAP
COMPLETELY
BACKFILL WITH TOP SOIL -
WATER IN 6" LAYERS, DO
NOT TAMP
SUBGRADE UNDER ROOTBALL TO BE
KEPT UNDISTURBED TO REDUCE
SETTLING OR COMPACT TOPSOIL TO
PROVIDE A FIRM BASE TO PREVENT
SETTLEMENT
PLANTING PIT 5' MIN. DIAMETER
TREE PLANTING -
EVERGREEN TREE
SCALE: NONE
AT TIME OF PLANTING TRIM ONLY DEAD,
BROKEN AND DOUBLE LEADER
BRANCHES
REMOVE ALL TREE WRAP
FLAGGING 10" SQ MIN.
ROOT FLARE SHALL BE 1" TO 2" ABOVE FINISH
GRADE. REMOVE EXCESS SOIL FROM ROOT BALL
AS REQUIRED TO EXPOSE ORIGINAL ROOT FLARE
3" DEPTH DECORATIVE ROCK MULCH -
KEEP BACK FROM TRUNK
TREE STAKES PLACED 2"
BELOW SURFACE
8.5" X 11" SIGN
LAMINATED IN PLASTIC
SPACED EVERY 50'
ALONG THE FENCE
0
v
NOTES:
CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA. 1. NO PRUNING SHALL BE PERFORMED EXCEPT BY
►; APPROVED ARBORIST.
KEEP OUT
TREE
PROTECTION
AREA
r
TREE PROTECTION
FENCING
SCALE: NONE
AM
NOT USED
SCALE: NONE
2. NO EQUIPMENT SHALL OPERATE INSIDE THE
PROTECTIVE FENCING INCLUDING DURING FENCE
INSTALLATION AND REMOVAL.
3. DEEP WATER TREE PRIOR TO FENCE INSTALLATION.
WATER AS NECESSARY DURING CONSTRUCTION.
TREE PROTECTION FENCE: HIGH DENSITY
POLYETHYLENE FENCING WITH 3.5" X 1.5"
OPENINGS; COLOR -ORANGE. STEEL POSTS
INSTALLED AT 8' O.C.
2" X 6' STEEL POSTS OR APPROVED EQUAL
5" THICK LAYER OF ORGANIC MULCH
MAINTAIN EXISTING GRADE WITH THE
TREE PROTECTION FENCE UNLESS
OTHERWISE INDICATED ON THE PLANS
RAINWATER BASIN FORMED
AS 4"-6" DEPTH DEPRESSION
AROUND SHRUB
CU
TOPSOIL ---'18" MIN.
PLANTING PIT. 24" MIN. DIAMETER
DO NOT INSTALL ROOTBOUND PLANS
SHRUB PLANTING
SCALE: NONE
RAINWATER BASIN
FORMED AS 4"-6" DEPTH
DEPRESSION AROUND TREE
FLOW
EXISTING GRADE
TOPSOIL
DO NOT INSTALL ROOTBOUND -
PLANTS.
24" MIN.
SIDES OF PIT SHALL BE
RAKED TO LOOSEN PRIOR TO
SETTING PLANTS IN PLACE
FENCE
PULL MULCH MATERIAL AWAY
FROM TRUNK
3" DEPTH DECORATIVE ROCK MULCH
SIDES OF PIT SHALL BE RAKED TO
LOOSEN PRIOR TO SETTING
PLANTS IN PLACE
GENTLY LOOSEN ROOTS AROUND
EXTERIOR OF ROOTBALL. DO NOT PRUNE
PLANTS WITHOUT LANDSCAPE ARCHITECT
APPROVAL DIRECTION.
SET ROOTBALL ON UNDISTURBED OR FIRMLY
PACKED SOIL
V'o D WOOD STAKES
o DO NOT DRIVE INTO ROOTBALL
REMOVE AT END OF PLANT
ESTABLISHMENT PERIOD.
PLANTING PIT F MIN. DIAMETER
TREE PLANTING
SCALE: NONE
PULL MULCH MATERIAL AWAY FROM
TRUNK
3" DEPTH DECORATIVE ROCK
FLOW
GENTLY LOOSEN ROOTS AROUND
EXTERIOR OF ROOTBALL..
SET ROOTBALL ON UNDISTURBED
OR FIRMLY PACKED SOIL
APPROVED FOR CONSTRUCTION
(APPROVER) (DATE)
1"',_
�
Z
V
Z
�_
W
W
W
W
W
Lu:iZ
O
oQZ
a�
m
LL W
r
O
a
(L
U)
0
O
r
cn
0
O
O
0
W
Z
m
O
(V
0
O
'
W
N
O
N
o)
N
(V
z
O
Q
V
UL
0
ON
�
J
z
M
0
w
0
O
w
W
�
W
z
O
L
Lu
U
�
x
')
H
z
z
J
W
�/
Z
—
z
0Lu
a'
Ir
Q
Q
1
0
Cv
o
m
LL
W
�
0
♦ ♦�
Lu
o
o
�
Z
g
p\
J
W
<
c)
a
ISSUED FOR CONSTRUCTION
SIGNATURE
NOTE
THIS DOCUMENT IS THE PROPERTY OF MICRON TECHNOLOGY, INC.
AND CONTAINS CONFIDENTIAL INFORMATION THAT IS PROTECTED BY
A CONFIDENTIALITY OR NON DISCLOSURE AGREEMENT EXECUTED BY
THE RECIPIENT, AND STATE AND FEDERAL LAW. UNAUTHORIZED
DISCLOSURE MAY RESULT IN CIVIL OR CRIMINAL LIABILITY.
TOOL MICAP:
LID:
TOOL ETI:
PROJECT COORD: SSCHELLER
ENG. COORD: PCHRISTENSEN
OWNER: JFIESELMAN
DRAWN BY: CARIZMENDEZ
PROJECT / WO:
C39982
REVISION
O
SHEET
EM—L-3001