HomeMy WebLinkAboutElevation (1)0'-0" AFF.
FINISHED FLOOR
9'-4" AFF
B.O. CANOPY
19'-2" AFF
T.O. PARAPET
21'-10" AFF
T.O. PARAPET
PAINTED
EIFS TO BE
EIFS TO BE PAINTED
ASSEMBLY
STOREFRONT
PAINTED
TO BE
CORNICE
PAINTED
EIFS TO BE
TO BE PAINTED
CORNICE
PAINTED
EIFS TRIM TO BE
SIGNAGE PACKAGE
SIGNAGE - REFER TO
EP-1
EP-2
EP-1
EP-1
EP-1
FIXTURE
LIGHT
ORANGE
LIGHT FIXTURE
SCHEDULE ORANGE
REFER TO LIGHTING
SHUTTERS
FLAT CANOPY
EP-6
FLAT CANOPY
EP-6
VENEER
THIN BRICK
PAINTED
BAND TO BE
EIFS ACCENT
PANEL SIDING
VERTICAL WOOD
PAINTED
1" EIFS TO BE
VARIANCE
APPLY FOR
SIGN VENDOR TO
GRAPHIC SIGNAGE
EP-3
EP-3 PAINTED
EIFS TO BE
EP-1 PAINTED
1" EIFS TO BE
EP-3
ORANGE FINISH
MANUFACTURER IN
PURCHASED FROM
DOORS ARE TO BE
LX-1
EQ
EQ EQ3"3"3"EP-1
EF-1
9'-3"11'-8 1/2 "2'-9 1/2 "8"3'-1 1/2 "EP-1
8'-0" AFF.
T.O. WALL
BE PAINTED
CORNICE TO
EP-1
FIXTURE
ORANGE LIGHT
FIXTURE
ORANGE LIGHT
EB-1
PAINTED
TO BE
EIFS BAND
1"
EP-1
GAS METER
WALL WITH EIFS FINISH
COOLER TO HAVE FRAMED
EP-3
PAINTED
TO BE
CORNICE
DT Side Elevation
Scale: 1/4" = 1'-0"
A3.1
Exterior Elevations
POPEYES
Entry Side Elevation
Scale: 1/4" = 1'-0"
C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
B
A
C
D
E
F
G
H
I
J
K
L
M
N
O
B
C
D
E
F
G
H
I
J
K
L
M
N
O
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Mark Description Date
Building Design & Documentation 2021-2022 Jeffrey Parker Architects Inc.
04/15/21
03/11/21
FOR SITE PLAN APPROVAL
Building for:
MERIDIAN, ID
3 1/2 "
4'-3"
4'-5"
1"10'-8"10'-1"5'9'-11"SPECIFICATIONS
SECTION 8D: GLAZING
MATERIALS
GENERAL PROVISIONS
SERVICE WINDOW.
1. SCOPE: FURNISH AND INSTALL GLASS IN STOREFRONT AND DRIVE-THRU
1/4” (6MM) GLASS
INSULATING UNIT CONSTRUCTION: 1/4” (6MM) GLASS + 1/2” (13MM) AIR SPACE +
OUTDOOR APPEARANCE: CLEAR
WWW.C2CCERTIFIED.ORG).
BRONZE LEVEL, BY CRADLE TO CRADLE PRODUCT INNOVATION INSTITUTE (
CERTIFICATION: BOTH LITES TO BE CRADLE TO CRADLE CERTIFIED™, MINIMUM
VITRO CERTIFIED FABRICATOR REQUIRED
APPROVED MANUFACTURERS:
OUTDOOR VISIBLE LIGHT REFLECTANCE: 11%2.6.
SHADING COEFFICIENT: 0.452.5.
SHGC: 0.392.4.
U-VALUE SUMMER : 0.272.3.
U-VALUE WINTER: 0.292.2.
VISIBLE LIGHT TRANSMITTANCE: 70%2.1.
PERFORMANCE VALUES:2.
LOCATION: SECOND SURFACE (2)
VITRO ARCHITECTURAL GLASS
LOW-E COATING: “SOLARBAN” 60 SOLAR CONTROL (SPUTTERED) BY 1.3.
INDOOR LITE: CLEAR (TRANSPARENT) FLOAT GLASS.1.2.
SURFACE (2)
OUTDOOR LITE: CLEAR GLASS, SPUTTER COATED ON SECOND 1.1.
“SOLARBAN 60 (2) CLEAR + CLEAR BY VITRO ARCHITECTURAL GLASS.
TYPE: SOLAR CONTROL LOW-E CLEAR INSULATING GLASS 1.
VINYL SHUTTER
(2) DOUBLE LOUVER
1" SPACE GAP
PAINTED EP-1
EIFS FRAME,
FOR ALUMINUM STRUCTURES.
ALLOWABLE STRESS IN ACCORDANCE WITH AA SPECIFICATIONS
WHEN TESTED IN ACCORDANCE WITH ASTM E 330 WITH
DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER 2.5.
DIRECTION): PER LOCAL CODE.
INTERIOR WALLS (PRESSURE ACTING IN EITHER 2.4.1.3.
NEGATIVE PRESSURE: PER LOCAL CODE.2.4.1.2.
POSITIVE PRESSURE: PER LOCAL CODE.2.4.1.1.
EXTERIOR WALLS:2.4.1.
INDICATED:
WITHSTAND WIND PRESSURE LOADS NORMAL TO WALL PLANE
WIND LOADS: COMPLETED STOREFRONT SYSTEM SHALL 2.4.
THE SILL FLASHING.
FLASHING ON ANY FASTENERS THAT PENETRATE THROUGH
HEADS MUST BE SEATED AND SEALED AGAINST SILL
FIELD TESTED IN ACCORDANCE WITH AAMA 503). FASTENER
10 PSF (479 PA) FOR YES 45 FI SYSTEMS. (OR WHEN REQUIRED, 2.3.1.
DIFFERENTIAL OF:
IN ACCORDANCE WITH ASTM E 331 AT TEST PRESSURE
WATER INFILTRATION: NO UNCONTROLLED WATER WHEN TESTED 2.3.
0.06 CFM/FT² (1.10 M ³ /H · M²) FOR YES 45 FI SYSTEMS.2.2.1.
ALLOWABLE INFILTRATION OF:
COMPLETED STOREFRONT SYSTEMS SHALL HAVE MAXIMUM
283 AT DIFFERENTIAL STATIC PRESSURE OF 6.24 PSF (299 PA),
AIR INFILTRATION: WHEN TESTED IN ACCORDANCE WITH ASTM E 2.2.
METHOD INDICATED.
MANUFACTURER'S ASSEMBLIES IN ACCORDANCE WITH TEST
REQUIREMENTS INDICATED, AS DEMONSTRATED BY TESTING
STOREFRONT SYSTEMS THAT COMPLY WITH PERFORMANCE
PERFORMANCE REQUIREMENTS: PROVIDE ALUMINUM 2.1.
SYSTEM PERFORMANCE DESCRIPTION2.
SHALL BE BY THE SAME MANUFACTURER.
SINGLE SOURCE REQUIREMENT: ALL PRODUCTS LISTED BELOW 1.1.
RELATED SECTIONS:1.
GLAZING)
YKK AP SERIES YES 45 FI STOREFRONT SYSTEM (INSULATING 1.1.
SECTION INCLUDES: ALUMINUM STOREFRONT, INCLUDING:1.
PART 1 GENERAL
SERIES YKK AP YES 45 FS/FI SERIES
ALUMINUM - FRAMED ENTRANCES AND STOREFRONTS YKK AP PRODUCT
SECTION TITLE
WARRANTY: SUBMIT WARRANTY DOCUMENTS SPECIFIED HEREIN.2.6.1.
CLOSEOUT SUBMITTALS:2.6.
AUTHORITY.
AND PHYSICAL PROPERTIES IF REQUIRED BY THE LOCAL PERMITTING
COMPLIANCE WITH SPECIFIED PERFORMANCE CHARACTERISTICS
TEST REPORTS: SUBMIT CERTIFIED TEST REPORTS SHOWING 2.5.1.
QUALITY ASSURANCE / CONTROL SUBMITTALS:2.5.
FINISH COLORS AND TEXTURES.
PRODUCT COMPONENTS, INCLUDING ANCHORAGE, ACCESSORIES,
REQUESTED. SHOP DRAWINGS SHOWING LAYOUT, PROFILES, AND
SHOP DRAWINGS: PROVIDE TO THE ARCHITECT OF RECORD IF 2.4.
DATE IN ORDER TO MAKE A VALID COMPARISON.
REPORTS MUST BE SUBMITTED TEN (10) WORKING DAYS PRIOR TO BID
CONSIDERED, SUPPORTING TECHNICAL DATA, SAMPLES, AND TEST
SUBSTITUTIONS: WHENEVER SUBSTITUTE PRODUCTS ARE TO BE 2.3.
RECORD.
STOREFRONT SERIES SPECIFIED AS REQUIRED BY THE ARCHITECT OF
PRODUCT DATA: SUBMIT PRODUCT DATA FOR EACH TYPE 2.2.
"CONDITIONS OF THE CONTRACT."
DRAWINGS, SAMPLES, AND SIMILAR SUBMITTALS ARE DEFINED IN
AND DIVISION 1 SUBMITTALS SECTIONS. PRODUCT DATA, SHOP
SUBMITTALS IN ACCORDANCE WITH "CONDITIONS OF THE CONTRACT"
GENERAL: PREPARE, REVIEW, APPROVE, AND SUBMIT SPECIFIED 2.1.
SUBMITTALS
SPECIFIED.
WILL BE AFFECTED BY THE CHARACTERISTICS OF THE GLASS
NOTE: THERMAL PERFORMANCE FOR THE GLAZED SYSTEM AS A WHOLE
YES 45 FI SYSTEMS.
THERMAL TRANSMITTANCE U VALUE: 0.51 BTU/HR/FT²/°F OR LESS FOR 2.7.2.
YES 45 FI SYSTEMS.
CONDENSATION RESISTANCE FACTOR (CRF F ): A MINIMUM OF 44 FOR 2.7.1.
AAMA 1503.1 AND NFRC 100:
THERMAL PERFORMANCE: WHEN TESTED IN ACCORDANCE WITH 2.7.
OR DETRIMENTAL EFFECTS.
DAMAGING LOADS ON FASTENERS, REDUCTION OF PERFORMANCE,
JOINT SEAL FAILURE, UNDUE STRESS ON STRUCTURAL ELEMENTS,
TEMPERATURE, WITHOUT CAUSING BUCKLING STRESSES ON GLASS,
BY 180 DEGREES F. (82.2 DEGREES C.) SURFACE
THERMAL MOVEMENT: PROVIDE FOR THERMAL MOVEMENT CAUSED 2.6.
ALUMINUM STRUCTURES.
ALLOWABLE STRESS IN ACCORDANCE WITH AA SPECIFICATIONS FOR
WHEN TESTED IN ACCORDANCE WITH ASTM E 330 WITH
DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER 2.5.
STRUCTURE.
SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO 2.
OR BITUMINOUS COATING.
CONCRETE, OR DISSIMILAR MATERIALS USING NYLON PADS
PROTECT ALUMINUM MEMBERS IN CONTACT WITH MASONRY, STEEL, 1.
SHOP DRAWINGS, AND WITHIN SPECIFIED TOLERANCES.
GENERAL: INSTALL MANUFACTURER'S SYSTEM IN ACCORDANCE WITH 1.
INSTALLATION
COLORS: AS SPECIFIED BY POPEYES LOUISIANA KITCHEN:6.
STOREFRONT SYSTEM: YKK AP YES 45 FI STOREFRONT SYSTEM.5.3.
ACCEPTABLE MANUFACTURERS: YKK AP AMERICA INC.5.2.
MANUFACTURERS (ACCEPTABLE MANUFACTURERS/PRODUCTS)5.1.
PART 2 PRODUCTS5.
WARRANTY PERIODS ARE AVAILABLE AT ADDITIONAL COST.
DATE OF SHIPMENT BY YKK AP AMERICA INC. EDITOR NOTE: LONGER
NO EVENT, SHALL START LATER THAN SIX (6) MONTHS FROM THE
COMPLETION FOR THE PROJECT PROVIDED THAT THE WARRANTY, IN
WARRANTY COMMENCING ON THE SUBSTANTIAL DATE OF
WARRANTY PERIOD: MANUFACTURER'S ONE (1) YEAR STANDARD 4.3.
AN AUTHORIZED COMPANY OFFICIAL.
MANUFACTURER'S STANDARD WARRANTY DOCUMENT EXECUTED BY
MANUFACTURER'S WARRANTY: SUBMIT, FOR OWNER'S ACCEPTANCE, 4.2.
FOR PROJECT WARRANTY PROVISIONS.
PROJECT WARRANTY: REFER TO "CONDITIONS OF THE CONTRACT" 4.1.
WARRANTY4.
CONSTRUCTION PROGRESS TO AVOID CONSTRUCTION DELAYS.
FIELD MEASUREMENTS, FABRICATION SCHEDULE WITH
RECORDED MEASUREMENTS ON SHOP DRAWINGS. COORDINATE
OPENINGS BY FIELD MEASUREMENTS BEFORE FABRICATION; RETAIN
FIELD MEASUREMENTS: VERIFY ACTUAL MEASUREMENTS / 3.1.
PROJECT CONDITIONS / SITE CONDITIONS.3.
MANUFACTURER'S WARRANTY REQUIREMENTS.
CONDITIONS, MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND
MEETING TO VERIFY PROJECT REQUIREMENTS, SUBSTRATE
PRE-INSTALLATION MEETINGS: CONDUCT PRE-INSTALLATION 2.2.
OWNER, SUBMIT REFERENCE LIST OF COMPLETED PROJECTS.
SIMILAR TO THAT REQUIRED FOR THIS PROJECT. IF REQUESTED BY
SECTION WHO HAS SPECIALIZED IN THE INSTALLATION OF WORK
DETERMINED BY CONTRACTOR) TO PERFORM WORK OF THIS
INSTALLER QUALIFICATIONS: INSTALLER EXPERIENCED (AS 1.1.
QUALIFICATIONS:1.
QUALITY ASSURANCE
INSTRUCTIONS.
ARE SEALED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION
COLLECTED IN GUTTERS AND WEPT TO EXTERIOR. VERIFY METAL JOINTS
5. VERIFY STOREFRONT SYSTEM ALLOWS WATER ENTERING SYSTEM TO BE
CONTINUOUS BEADS OF SEALANT.
EXTRUDED FLASHING CONTINUOUS WITH SPLICE JOINTS; SET IN
4. PROVIDE SILL FLASHING AT EXTERIOR STOREFRONT SYSTEMS. EXTEND
STRUCTURE.
3. SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO
DRIVE THRU SPECIFICATIONS
ENGINEER.
ALL OTHER TYPES OF ANCHORING TO BE APPROVED BY CERTIFIED 6)
SILICONE ALL EXTERIOR AND INTERIOR JOINTS.5)
(CHECK FOR ANY LOCAL CODES OR CITY CODES)
RECOMMENDED HEIGHT FROM FLOOR TO SERVCE OPENING TO BE 36". 4)
115V/15 AMP. DEDICATED CIRCUIT FEATURE.3)
SCHEDULE.
ANCHOR ACCORDING TO THE LOCAL BUILDING CODE ANCHOR 2)
PROPERLY.
QUIKSERV WINDOWS MUST BE INSTALLED LEVEL AND SQUARE TO WORK 1)
INSTALLATION:
JUNCTION BOX TO BE SUPPLIED BY CONTRACTOR.3)
ANCHOR SCREWS TO BE SUPPLIED BY THE CONTRACTOR.2)
TO BE MOUNTED ON THE WALL.
EYE SET TO BE MOUNTED DIRECTLY BELOW THE SERVICE OPENING. BAR 1)
ROUGH OPENING 72 1/2" (W) x 41 1/2" (H)
ACTUAL DIMENSIONS: 72" (W) x 27" (H)
GENERAL NOTES:
BUILDING CODE
MODEL # BP-7241E-IP - HIGH WIND ZONE AS DETERMINED BY THE LOCAL
MODEL # BP-7241E - STANDARD INSTALLATION
DRIVE THRU WINDOW - QUIKSERV
A17
8
A10
5
A10
4B
A9
1
A8
4
A9
2
A8
1
A10
5
4B
A10
A10
6B
A10
6B
A10
6A
A10
6A
CANOPY
PANEL SIDING
NEW VERTICAL WOOD
EP-1
BE PAINTED
1" EIFS BAND TO
A6
4
0'-0" AFF.
FINISHED FLOOR
9'-4" AFF
B.O. CANOPY
19'-2" AFF
T.O. PARAPET
21'-10" AFF
T.O. PARAPET
8'-0" AFF.
T.O. WALL
20'-6" AFF.
T.O. PARAPET
PAINTED
EIFS TO BE
EIFS TO BE PAINTED
BE PAINTED
CORNICE TO PAINTED
TO BE
CORNICE
FIXTURE
ORANGE LIGHT
BE PAINTED
CORNICE TO
SHUTTERS
TO BE PAINTED
SURROUND
EIFS SHUTTER
PAINTED
BAND TO BE
EIFS ACCENT
ASSEMBLY
STOREFRONT
EP-1
EP-1
EP-5
EP-1
EP-1
LIGHT GREY
BAND PAINTED
EIFS ACCENT
FIXTURE
ORANGE LIGHT
FIXTURE
ORANGE LIGHT
NEW CANOPY
EP-6
EP-6
PAINTED
1" EIFS TO BE
D.T. WINDOW
ASSEMBLY
STOREFRONT
WALL WITH EIFS FINISH
COOLER TO HAVE FRAMED
SIGNAGE PACKAGE
NEW SIGNAGE - REFER TO
EP-2
PAINTED
RAILING TO BE
EP-2
EP-1
EP-3
EB-1THIN BRICK
EP-3EF-3
EF-1
LX-1
LX-1
LX-1
CANOPY
EQ EQ EQ3"3"EQ EQ
��
PAINTED
TO BE
CORNICE
EP-1
8'-7"11'-0 1/2 "3'-1 1/4 "2'-9 1/2 "8"SIGNAGE PACKAGE
NEW SIGNAGE - REFER TO