Loading...
HomeMy WebLinkAboutWestborough Square Subdivision FP-05-075 BEFORE THE MERIDIAN CITY COUNCIL IN THE MATTER OF THE APPLICATION OF JLJ ENTERPRISES, INC. FOR FINAL PLAT APPROVAL OF 1 MULTI- FAMILY RESIDENTIAL BUILDING LOT CONSISTING OF TEN 4- PLEXES AND 6 COMMERCIAL OFFICE BUILDING LOTS ON 5.4 ACRES IN R-15 AND L-O ZONES LOCATED AT 6015 NORTH JERICHO ROAD IN A PARCEL OF LAND BEING ALL OF LOT 6, BLOCK 1, WESTBOROUGH SUBDIVISION LOCATED IN THE NE ~ OF NE % OF T. 4N., R.1E., SECTION 30 C/C January 10, 2006 ) ) ) ) ) ) ) ) ) ) ) ) ) CASE NO. FP-05-075 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council for Final Plat approval pursuant to Unified Development Code 11-6B-3 on January 10, 2006, and the Council finding that the Administrative Review is complete from Sonya Watters, Assistant City Planner for the Planning and Zoning Department, and Michael Cole, Development Services Coordinator for the Public Works Department, dated: Hearing Date: January 10, 2006, to the Mayor and Council, and the Council having considered the requirements ofthe preliminary plat the Council takes the following action: IT IS HEREBY ORDERED THAT: ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR WESTBOROUGH SQUARE SUBDIVISION / (FP-O5-075) Page 1 of 4 1. The Final Plat of"PLA T SHOWING WESTBOROUGH SQUARE SUBDIVISION IN A PARCEL OF LAND BEING ALL OF LOT 6, BLOCK 1, WESTBOROUGH SUBDIVISION LOCATED IN THE NE % OF NE % OF T. 4N., R. IE., SECTION 30, BOISE MERIDIAN, MERIDIAN, ADA COUNTY, IDAHO 2006, HANDWRITTEN DATE: 11/14/2005, SHEET 1 OF 3 , W&H PACIFIC", JLJ ENTERPRISES, INC., Developer, is Conditionally Approved subject to those conditions of Staff comments as set forth in the Memorandum to the Mayor and City Council from Sonya Watters, Assistant City Planner for the Planning and Zoning Department and Michael Cole, Development Services Coordinator for the Public Works Department, dated: Hearing Date: January 10, 2006, listing 17 SITE SPECIFIC REQUIREMENTS/FINAL PLAT and 14 GENERAL REQUIREMENTS, a true and correct copy of which is attached hereto marked Exhibit "A", and consisting of 4 pages, and by this reference incorporated herein, and the additional requirements from the action of the council taken at their January 10, 2006 meeting as follows, to-wit 1.1 Adopt the Recommendation of the Central District Health Department as follows: The Central District Health requires after written approval from the appropriate entities are submitted, they can approve this proposal for central sewage and central water; that plans must be submitted to and approved by the Idaho Department of Health and Welfare, Division ofEnviromnental Quality for central sewage and central water; that run-off is not to create a mosquito breeding problem; any existing septic systems on this property must be properly abandoned; and it is suggested ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR WESTBOROUGH SQUARE SUBDIVISION / (FP-O5-075) Page 2 of 4 that the stonnwater be pretreated through a grassy swale ptior to di scharge to the subsurface to prevent impact to groundwater and surface water quality; that engineers and architects should obtain current best management practices for stonnwater disposal and design a stormwater management system that is preventing groundwater and surface water degradation. Manuals for guidance: 1. State of Idaho Catalog of Stormwater Best Management Practices for Idaho Cities and Counties. Prepared by the Idaho Division of Environmental Quality, July 1997. 2. Stormwater Best Management Practices Guidebook. Prepared by City of Boise Public Works Department, May 2000. 2. The final plat upon which there is contained the Certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 1. The Plat dimensions are approved by the City Engineer; and 2. The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code 67 -8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A ORDER OF CONDITIONAL APPROV AL OF FINAL PLAT FOR WESTBOROUGH SQUARE SUBDIVISION / (FP-O5-075) Page 3 of 4 request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty-eight (28) days after the date of this decision and order, seek a judicial review as provided by Chapter 52, Title 67, Idaho Code. By action of the City Council at its regular meeting held on the ~ day of J!\UQ") , 2006. By: \11\,\I'HlIlIlJì~y e eerd \,\' Or: MË;~II' "", "'\ .- , t. , ity of Meridian ,:. ~ <t,L '" ~ CJ '..rpY\POfl'-1.,..þ, v \. ~ 4"' <"() - JdL:Þ-~ ~ "SEAL eo : William G. Berg, Jr.~ ~it; cler~ %. ~~ ,,~Çj.o j ~ .,() ~'! 1'],"1: . ~ ".. . . "'-'" '1 . - ~ 'r ,<~: .. . Copy served upon ApplIcant, the Plannll1g â'n,g ~Bep~ent, PublIc Works Department, and II, III City Attorney. 'Ir-"", ,,\\1" Attest B: Dated: \-J,LD-OLD ORDER OF CONDITIONAL APPROV AL OF FIN'AL PLAT FOR WESTBOROUGH SQUARE SUBDIVISION / (FP-O5-075) Page 4 of 4 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT TO: Mayor & City Council Sonya Watters, Assistant City Planner SIll Michael Cole, Development Services Coordinator (Y\ C cA.{;;ri di ~n -~ ~ '\ \ IlJ.\HO } ~~ J: ~.., I' :ลก<~ ". -'>/"'" "--<'l~".l'.!,,-~~~,:~~r'~ '. ~¡ STAFF REPORT: Hearing Date: January 10,2006 Transmittal Date: January 6, 2006 FROM: SUBJECT: Westborough Square Subdivision Request for Final Plat Approval of West borough Square Subdivision Consisting of 1 Multi-family Residential Building Lot and 6 Commercial Office Lots on 5.4 Acres in an R-15 and L-O Zone by JLJ Enterprises (File# FP-O5-075) We have reviewed this submittal and offer the following comments and conditions of the applicant. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, JLJ Enterprises, Inc., has applied for final plat approval of 1 multi-family residential building lot and 6 commercial office building lots on 5.4 acres in the R-15 and L-O zones. The residential lot will consist of 10 four-plexes containing a total of 40 residential units. Westborough Square Subdivision is a re-subdivision of Lot 6, Block 1 of Westborough Subdivision which is located in a portion of the NE ~ of the NE ~ of section 30, Township 4 North, Range 1 East, Boise Meridian. The site is located on the south east comer of Chinden Boulevard and Jericho Road, approximately ~ mile west ofN. Locust Grove Road. A conditional use permit for a planned development was approved for this subdivision that allowed for a reduction to the required standards for street frontage to be reduced to zero feet and multiple principle detached buildings to be constructed on a single lot. Amenities provided with this subdivision are as follows: a plaza with benches, planters, tables, and trees with a more direct walkway from the plaza to the multi-family portion of the development and a tot lot to be located within the multi-family portion of the development. The final plat submitted for this phase substantially complies with the approved preliminary plat. Staffrecommends approval of West borough Square Subdivision with the comments and conditions stated in this report. SITE SPECIFIC REQUIREMENTS 1. Applicant is to meet all tem1S of the approved development agreement (Inst. No. 105152707), preliminary plat (PP-05-020), and conditional use permit (CUP-05-027) for this development. 2. All subdivisions in the City of Meridian require each lot be provided with pressurized irrigation. The construction plans submitted concurrently with this plat do not show any pressurized irrigation plans. If the system is to be privately owned and maintained plans and specifications will be reviewed by the Public Works department as part of the construction plan review. A draft copy of the Operations and Maintenance manual shall be submitted prior to plan approval. If the Exlùbit "A" FP-O5-075 Westborough Square Subdivision FP.doc PAGEl 3. 4. CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT system is to be owned and maintained by an irrigation district then evidence of a license agreement or letter of plan approval shall be submitted prior to scheduling of a pre-construction meeting. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the ilTigab1e COlllil1on areas prior to signature on the final plat by the Meridian City Engineer. All fencing installed on the site must be in compliance with UDC 11-3A-6 and 11-3A-7. Temporary construction fencing to contain debris shall be installed around the perimeter of the subdivision where pennanent fencing is not proposed. 5. The applicant is proposing sanitary sewer service to this site via mains that flow to a lift-station in Arcadia Subdivision. Prior to certificates of occupancy the applicant shall be responsible for any upgrades to the lift-station or the pressure line leaving the lift-station that may be required. This condition may be waived by the City Engineer at his discretion or if gravity means becomes available through Saguaro Canyon which would de-activate the lift-station. 6. The applicant shall install mains to and through this proposed development. The applicant shall coordinate main size and routing with the Public Works Department. Cover over sanitary sewer mains shall be no less than three feet from finish grade to the top ofthe pipe. If cover is less than three feet from the sub-grade to the top of the pipe, alternated pipe materials shall be used per the Meridian Public Work's Standard Specifications. 7. Water service to this site is being proposed via an extension of water mains located Jericho road. Prior to certificates of occupancy an additional water connection through the school or through Saguaro Canyon shall be required. The applicant shall construct water mains to and through this proposed development. Applicant shall execute City of Meridian standard fOlll1S of easements, for any mains that are required to provide service. Coordinate main size and routing with Public Works. 8. Provide a 20' easement for all public water/sewer mains outside of public right of way (include all water services and hydrants). Graphically depict these easements on the plat and reference the instrument number in a plat note. 9. Prior to signature of the final plat by the City Engineer, provide a cross parking/cross access agreement for all of the new lots within the subdivision to use the drive aisles and parking areas (including sidewalks). Maintenance of the drive aisles and parking areas should be provided for in a note on the face ofthe final plat, AND/OR in a document such as CC&Rs. 10. There must be a minimum 20- foot separation between seepage beds and building foundations per Department of Environmental Quality's standard specifications. 11. Maintenance of all common areas, including but not limited to: drive aisles, parking areas, landscaping, etc., shall be the responsibility ofthe Westborough Square Owner's Association. 12. Include instrument number of warranty deed referenced on the face of the plat. Also, remove "(Waiting on Jewett)" from this note. 13. All required landscape buffer easements shall be depicted and labeled on the face of the plat. Exhibit "A" FP-O5-075 Westborough Square Subdivision FP.doc PAGE 2 14. CITY OF MERIDIAN PLANN1NG AND PUBLIC WORKS DEPARTMENTS STAFF REPORT The landscape plan, prepared by The Land Group and dated 10/25/05, shall be revised as follows: a. The applicant shall work with the City Arborist, Elroy Huff, on designing, adopting, and implementing a protection/mitigation plan for the existing trees on site. The plan shall be revised to reflect the requirements stated in UDC 11-3B-1 O. Relocate the trees shown along Jericho Road south of the driveway that are within the right-of-way. A lO-foot wide landscape buffer is required on the east side of the sidewalk and trees shall be located within this buffer, outside of the right-of-way. b. Submit 3 copies of the revised landscape plan to the Planning Department prior to signature on the final plat by the City Engineer 15. Revise or add the following note(s) on the face of the plat dated 11/14/05, prepared by W&H Pacific, prior to signature on the final plat by the City Engineer: (4.) (8.) ". ...and with conditional use permit No. 03 04305-027." Staff recommends but does not require removing that portion from this note that dedicates a 5-foot public utilities, drainage and irrigation easement along interior lot lines. Add note prohibiting vehicular access to this site from Chinden Boulevard. (*.) 16. Complete the Certificate of Owners and accompanying acknowledgement. 17. Staff's failure to cite specific ordinance provisions or terms of the approved development agreement, preliminary plat, or conditional use pennit does not relieve the Applicant of responsibility for compliance. GENERAL REQUIREMENTS 1. All iuigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per UDC 11-3A-6. Plans will need to be approved by the appropriate iITigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, alternative plans will be reviewed and approved by the meridian City Engineer prior to final plat signature. 2. Street signs are to be in place, water system shall be approved and activated, fencing installed, drainage lots constructed, road base shall be approved by the Ada County Highway District, and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. 3. A letter of credit or cash surety in the amount of 110% shall be required for all uncompleted fencing, landscaping, amenities, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 4. A written certificate of completion shall be prepared by the landscape architect, landscape designer or qualified nurseryman responsible for the landscape plan upon completion of the landscape installation. The Certificate of Completion shall verify that all landscape improvements, including plant materials and sprinkler installation, are in substantial compliance with the approved landscape plan. Exhibit "A" FP-O5-075 Westborough Square Subdivision FP .doc PAGE 3 CITY OF MERIDIAN PLANNING AND PUBLIC WORKS DEPARTMENTS STAFF REPORT 5. All development improvements, including but not limited to water, sewer, fencing, micro-paths, pressurized inigation and landscaping shall be installed and approved prior to obtaining certitìcates of occupancy. 6. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as detennined during the plan review process, prior to signature on the tìna1 plat per Resolution 02-374. 7. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape inigation. 8. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backtìll, where footing would sit atop tìll material. 9. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street tìnish centerline elevations are set a minimum of three feet above the highest established nonna1 groundwater elevation. 10. Coordinate tìre hydrant placement with the City of Meridian Public Works department. 11. Applicant shall be responsible for application and compliance with any Section 404 Pennitting that may be required by the Army Corps of Engineers. 12. Applicant shall be responsible for application and compliance with and NPDES Permitting that may be required by the Environmental Protection Agency. 13. All development features shall comply with the Americans with Disabilities Act and the Fair Housing Act. 14. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. STAFF RECOMMENDATION Staff recommends approval of the tìnal plat for Westborough Square Subdivision with the above stated comments and conditions. Exhibit "A" FP-O5-075 Westborough Square Subdivision FP.doc PAGE 4