HomeMy WebLinkAboutCC - Landscape Plan GENERAL LANDSCAPE NOTES GENERAL IRRIGATION NOTES •• � ••""'•��
•• •••SSA YE4 ' .
% �
1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN
LANDSCAPE PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF CORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF • �`` �"�
THE LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT
ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL
IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS BE CONTRACTOR'S RESPONSIBILITY.
/� • LA-165;7 •
INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED OR : `f�'•. 5/1q/21 .•' •`
SOD, EDGING, AND DRIP LINE QUANTITIES. 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION •� •.••••••••SYSTEM 4 •.
E. CRESCENDO ST. 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF AREAS. WHICH PROVIDES THE WORKSHALL CONSIST EOFAPROV DIINGTER RAND INSTALLING AGE TO ALL WALL NMATERIALS PLANTING ��I�ID,;;p"- ��,•
\ AVAILABLY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT OF CONNECTION, PIPE,
' �• SPECIFIED PLANT IS NOT AVAILABLE, THE LANDSCAPE ARCHITECT WILL PROVIDE VALVES, FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR.
. . .
ALTERNATE PLANT MATERIAL SELECTIONS. SUCH CHANGES SHALL NOT ALTER THE
• s •• 9' ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK
• O O O O s
• 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS.
UTILITIES WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG
LINE, INC. ® 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES.
• UTILITIES AND SERVICES DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER
• O O ,• O O SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE. FOR PREVENTION OF BACKFLOW AND BACK-SIPHONAGE
7
• 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF
O
7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED a O O O THE CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING
REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO AS APPROPRIATE.
: NOTIFY THE RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING
CONDITION. 8. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION
OO O O 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS. RATES WITHIN EACH CONTROL VALVE.
ALL DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, 9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER
AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL
OO O O OPERATIONS. FINISH GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW DEMAND AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM
LLi
AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE. THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS.
ui } Q 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO N
Q O6 � 6O > O6 J O6 z SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING z
x J Q J O INCH IN SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. AREAS. p
BLOCK 6 u BLOCK 5 a BLOCK 4 BLOCK 3 N
Q 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO �
vi O7 m O7 O7 m O7 a a FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE L
MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN A a WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS
Q MATERIALS AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEET THESE THAN ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE
vi MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED
O8 Q O8 O$ O8 FUTURE IMPORTED TOPSOIL OR, AMEND THE ON-SITE TOPSOIL. ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR
RESIDENTIAL SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS.
e
8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.; 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND
PLANTER BEDS - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE O ASE OF TREATED WITH A PRE-EMERGENT HERBICIDE. VAULTS WITH DURABLE TAGS CARRYING THE WARNING "DANGER-UNSAFE WATER OR 9 O9 O9 Og FUTURE PH II
20 APEX NW NON-POTABLE WATER."
SUBDIVISION
COLLECTOR 'I 9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH
LANDSCAPE Q II POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF 13. INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE
BUFFER 10 10 r. 10 • 10 I AREAS SHALL NOT EXCEED 3:1. ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS,
MEASURED ,, 6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS.
BACKFROM
OF 10. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S
�• 11 11 I �. 11 11 RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A
CURB I I INSTALLATION OF PLANT MATERIALS AND MULCH. SINGLE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND
'� 'I s; •' I ACCESSORIES.
2p' I ' ° ;1 �' I k. 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR
I f I j' 12 12 I 12 12 I TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING 15. A MIN. OF 4" POP-UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO
COLLECTOR
LANDSCAPE II I ' CONDITION. BE USED IN ALL PLANTER BEDS.
BUFFER
MEASURED I :;" I • 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER
FROM I PORTION OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED VELOCITY IN ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE
BACK OF
I , 13 13 I 13 13 I BACK AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND SIZE TO BE 1 .
�
CURB ,, LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS
PRIOR TO BACKFILLING. 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY,
PARKING, AND WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE.
13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING IDENTIFY ENDPOINTS OF SLEEVING.
E. PHENOMENAL ST. Lu> AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND
DEAD OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A
\ SPECIES AT NO COST TO THE OWNER. VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD
7- DdAA1C7
� SURFACE.
N 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER (V
U
MANUFACTURER'S RECOMMENDATIONS. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND
7x
O ALL REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. O
15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: SIZE WIRE AND CONDUIT AS REQUIRED.
N z
• PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS
INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. z
DISEASE UNTIL FINAL ACCEPTANCE BY OWNER. REPAIR INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS,
k PUBLIC ALLEY CONTROL WIRES AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR O z
FUTURE RE-SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING un O Q
AMENITY SPACE CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM
k0 RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. \
DEAD MATERIAL. /_
21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS
k TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS w
NEEDED. FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF
CONSTRUCTION.
ko CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN (� z
APPARENT AND WEATHER AND SEASON PERMIT. LU
X k } DRAWINGS AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL
m J I INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND
Q CONTACT THE OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR. 0
k APEX NW SUBDIVISION m
COMMERCIAL 1' ACHD LANDSCAPE NOTES 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL w - U
NO. 1 PROVIDE A NEAT AND LEGIBLE AS-CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND (n
o a (C-C) 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM MAINTENANCE MANUAL, AND UP TO (8) HOURS OF ORIENTATION AND/OR TRAINING FOR THE w 0
kDRAIN PIPE, STRUCTURES, OR FACILITIES. OWNERS MAINTENANCE AND OPERATIONS STAFF. z
2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF Q
CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. IT'S ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR O J
a SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO
Z
k > THE OWNER. z
w Q
w Q z 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND X
a k X p WINTERIZATION DURING THE GUARANTEE PERIOD. LJ..I
o Q aaC
UO
PUBLIC ALLEY/ ;;C X
Q
z k
I
NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF OPEN
k SPACE TREES PER CITY OF MERIDIAN UDC AND ARE NOT OPEN SPACE CALCULATIONS.
g REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL QUALIFIED OPEN SPACE CALCULATIONS. PLANT SCHEDULE SEE L2.0 FOR FULL PLANT SCHEDULE
N k 0
STREET TREE CALCULATIONS (1TREE/35 LF) TREES BOTANICAL/COMMON NAME/` o/
a7 MIN. z
o STREET NAME BUFFER LF CALC REQ PRVD ACER TRUNCATUM 'PACIFIC SUNSET'TM
U / WIDTH PACIFIC SUNSET MAPLE 0
Z S. APEX AVE. 20' 1073 1073 LF/35 31.00 32.00
CARPINUS BETULUS U
S. HOPE AVE. 13.5' 1073 1073 LF/35 31.00 32.00 EUROPEAN HORNBEAM
a
E. LAKE HAZEL RD. S. ASPIRATION AVE. 15' 1070 1070 LF/35 31.00 32.00 p[
0 1253 GLEDITSIA TRIACANTHOS'IMPERIAL'
E. CRESCENDO ST. 13.5' 1253 LF/35 36.00 36.00 IMPERIAL HONEYLOCUST
EXCLUDES GAS z
EASEMENT 0
�• PYRUS CALLERYANA'REDSPIRE'
TOTAL STREET TREES 129.00 132.00 REDSPIRE CALLERY PEAR
E N G I N E E R I N G
01
3 L / MITIGATION REQUIREMENTS GROUND COVERS BOTANICAL/COMMON NAME 5725BOI NORTH
D ISC V RY3WAY
0 / ! THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL PHONE 208 639-6939 O
o ( ) LL
TURF w W kmengllp.com
LANDSCAPE SITE PLAN TOTAL TREES REQUIRED/PROVIDED RHIZOM TOUST TALL
o
129.0 132.0 W
Z RHIZOMATOUS TALL FESCUE DESIGN BY: KAC \w
0 0 80 160 240 DRAWN BY: KAC /
CONTACT INFORMATION
a Plan Scale: 1 = 80 CHECKED BY: AY 0
Z OWNER LANDSCAPE CONSULTANT DATE: 5/14/21
BRIGHTON DEVELOPMENT INC. KM ENGINEERING, LLP Y 0-
2929 W. NAVIGATOR DR., SUITE 400 5725 NORTH DISCOVERY WAY PROJECT: 21023
Z MERIDIAN, IDAHO 83642 BOISE, IDAHO 83713 SHEET NO. Q
w PHONE: (208) 378-4000 PHONE: (208) 639-6939
CONTACT: JON WARDLE FAX: (208) 639-6930
E EMAIL: jwordle@brightoncorp.com CONTACT: ALYSSA YENSEN, PLA L1.0 O
75
EMAIL: oyensen@kmengllp.com
V
•••` g 0 F ID ''•.
SSA YES '*
0 1A 165;7
F — — — — — — — — — 5 — — — — — — — — 5 \ c� \ 6 I . s • • •
Q I :
p �I D I C is"sD ,,��'•.,`9NDSCA4�,• •.
- - - - - - - - -I '1111111111��`,
00 4 ° 4 p 4 p
/y W d �`1' pW W W • W W �W W a ° W W W W W W W W :• W W r W W W
+ rW W •� W W••W • W W .may. W W••W W.. • 0•Y� W • W W W W � �• W W W Y• W W .W J W W ♦W W. W W •W W W W W W W W W W W W W••W W W
W W W W W W W W W W •W W W W W
p 2 W�
oe
NP
$„W 8„ 8„W 8„W 8„W 8„W 8"W 8„W 8„W i 8„W 8,W „W 8„W 8„W 8„ 8"W 8„W $„W 8„W 8„W 8"W
a0 a o \ \
2 N 2 4 Cq 1 E. CRESCENDO ST. 2 \\ \\
°° 00 s 8"S 8"s 8"S 8"S 8"s�—8"s
y d sca
00 —W W W W \ \ W
• • • •W W W W . W � W W W W W W W W W
\ •. W W .W. W..W ° .. •• ♦♦ 00 W W IW W •W W W W •W 4 p • • • ° d Q
d° W W W W W d Q
e p 4 J/ ° 4 ° p p W W W W W W . . . W
° p 4
6"PI 00 6' ° PI PI PI PI PI PI P PI PI °
d d
Co 6"PI 6"PI 6"PI 6"PI 6"PI— 84 W 4 W W
U1 W b O \
� W �
• ° d W \
O W ° W \
W 00 W 1 1 W• O � O S N
° W W G : Do W \
a ° FL
W N W d d \
I ° � � W W
W ° d W W° d1° \\ KEY NOTES (TYPICAL) ® �„
d \ z
W cn W \ 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL p
p W °° \ TREES WITHIN TURF AREAS. N
a \
W O2 °s O S W • O s O • W \ 2. CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISION w �_
• W! W e _ \ TRIANGLE. THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY
W W 4 ° W ° W \ WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE.
N W \
d __X4
W W \
p • • 3. NOT USED.
00
W 3 3 W \ 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP.
W O
\
W W W O3 p O S \ 5. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10'
O O d
W Q W S W d W ao
d W s 4 ° a W CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES.
W W� 3& W ° a 6. 10' MULTI—USE PATHWAY. SEE CIVIL PLANS.
4 W
d W 00
J/
W 4 W 4 W W 7. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR o
W W ° W W ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE ANDFL
z
O O s O p O4 sW W _ PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW
W 00 W 4 W. C a AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN
•W 4 WW W W `° W a • 0 FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE
dp .y W W c W W PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW
W s W CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION
W W p W s •W d W a SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING
W ° d W W W p ° CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER
W W W THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO
I W ° w O 4 W W S W WO .w O SW ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF
> � s •W LLI p J W u j THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN
Q W J W > W J > W OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION.
W v W Q p _ 'Q Q a
• /\ U W Q W U — W •
° y, d •W d J °(O W J z W
p Q 00 W Co W W Co W O _
�, • O W. �> H a0
(/� /� W N = W �° Q 4
O 4 S W N W
W O O SW O
• W p 6 s s
, •W 0_ W W 4 ° d • if
3 W d p fD W W l
W BLOCK 6 BLOCK 5 W W •W BLOCK 4 a BL0000
K 3 W —� W PLANT SCHEDULE N
00 0- TREES BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS QTY O
W au W O d p d d O W S W O 1 O W W ACER TRUNCATUM'PACIFIC SUNSET'TM 2"CAL.B&B 35'X30 CLASS II 54
d N .W z
00 W W — PACIFIC SUNSET MAPLE O
•W d p 00 W
W 3 W W W W 4 a W W 4 • CARPINUS BETULUS 2"CAL.B&B 50'X40' CLASS II 40 V 1 0 7
S • EUROPEAN HORNBEAM z
O 0 W O p • W
W ' d S O ° ° O S cn W J
a• W a 40 GLEDITSIATRIACANTHOS'IMPERIAL' 2"CAL.B&B 40'X35' CLASS II 20 Q` c—
W W W W
— W ° � d p ° o_ W IMPERIAL HONEYLOCUST 0 _
uj
W N 00 d ° UJ W W W00
W 0_
W W W PYRUS CALLERYANA'REDSPIRE' 2"CAL.B&B 40'X25' CLASS II 18 Z Q
m W e W ° d • 'V ••
N W 4 p d W W 00 W REDSPIRE CALLERY PEAR Q
V I 1 W O O W ° U
S S O O S W
4 O W 1 W W ° v ro Wr o GROUND COVERS BOTANICAL/COMMON NAME CONT QTY W Q
• W w z
~ p W W
� W d S �, e
W W d • W TURF SOD RHIZOMATOUS SOD 36,462 SF Q
p W W W RHIZOMATOUS TALL FESCUESA
J
W W
0
• �, 10 4 10 W s W 10 ® 10 W 00 O
Z ° • y p W
Q e d
W W
z ` 4 W 1 W Z
VZ I w
W p W W
W / W
5 J • V) • 4 dp �O 5 I (n •W r N W
y I d O � � W / •+' W
11 11 I I®al W O ° °s O W W
-S W 11 11 Ws
z I F al W I W W S I W W o REMOVE DEAD/ DAMAGED
W W , BRANCHES AND PRUNE TO
l7 II W d `�' � N
3 i o I I W °° INTERNATIONAL SOCIETY OF
Co
ARBORICULTURE STANDARDS;
IMPROPERLY PRUNED TREES
_ _ O (AS DETERMINED BY THE
II 12 12 S s 12 12 IW W W
Z II a W a O LANDSCAPE ARCHITECT)
00 I I � W .0 I I W °° :W O O O SHALL BE REMOVED AND z
4 f W W W W W W W a (2)—BVC WOOD TREE Oo 0o O REPLACE. O
W STAKES(MIN. 6' HT) O TRUNK FLARE. LOCATE PRIOR
CHAINLOCK 0000 O TO PLANTING. FLARE SHALL
o I I 3 I i q iW a I P lei W W W TREE TIES O O BE VISIBLE AFTER PLANTING. U
U I 00 W MULCH PER PLAN KEEP
Z I 12"sD \ 13 13 I s �� 13 13 d W 3 MIN 1"-2" AWAY FROM TRUCK
O I � / �° I W W\
FLARE
_ 4 I _ _ W FINISH GRADE (�
EP sue— s 3 _ 3" HT. WATERING BASING z
a — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — BALL I O
Q _ ROOT— _ BERM
S �yz ` DEPTH I I a FERTILIZER TABLETS
M _ U
—� I—I —�I I FOLD BACK BURLAP FROM
N
7 7 II I I I I I II I II II I I I III TOP j OF ROOTBALL.
E. PHENOMENAL ST. REMOVE WIRE BASKET. O
NOTE: REMOVE TREATED ROOT— BACKFILL SOIL MIX GENTLY E N G I N E E R I N G L.L
OR SYNTHETIC BURLAP BALL PACK BACKFILL USING WATER 5725 NORTH DISCOVERY WAY
3 COMPLETELY. REMOVE WIDTH TO SETTLE SOIL AROUND BOISE,IDAHO 83713
o ANY SOIL AND/OR ROOTBALL PHONE(208)639-6939 O
MULCH AWAY FROM 8" MIN �NTING8" MIN kmengllp.com z
ROOTBALL ON UNDISTURBED
LANDSCAPE P TREE CROWN AFTER PIT SHALL BE A MIN. 2 TIMES WIDER SOIL
E INSTALLATION. DESIGN BY: KAC
THAN ROOTBALL AT BASE AND A
0 0 40 80 120 MIN. 3 TIMES WIDER THAN ROOTBALL DRAWN BY: KAC
AT FINISH GRADE. DEPTH SHALL BE
a Plan Scale: 1" =40' NOTES: SAME AS THE ROOTBALL. CHECKED BY: AY Q
w 1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED DATE: 5/14/21 z
STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL —
Y STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. PROJECT: 21 023
SHEET NO.
DECIDUOUS TREE PLANTING AND STAKING DETAIL J
Z NTS W
L2.0 �
V