Loading...
Applicant Response to Staff ReportPage I of 2 Machelle Hill From: Joe Silva Sent: To: Cc: Thursday, March 06, 2008 1:43 PM Joe Silva; 'Lars Anderson, Q-FY OF MERIDIAN CITY CLERK OFFICF I sstanfield@mseng.us'; C. Caleb Hood; Machelle Hill; Nancy Radford; Sheree Finch; Tara Green; Jennifer Veatch; bairdt@ci. meridian. id. us Subject: RE: Regency at River Valley- Revised From: Joe Silva Sent: Thursday, March 06, 2008 1:28 PM To: Lars Anderson Cc: sstanfield@mseng.us; Caleb Hood (hoodc@ meridian city.org); Machelle Hill; Nancy Radford; Sheree Finch; Tara Green; Jenny Veatch (veatchj@meridiancity.org); bairdt@ci.meridian.id.us Subject: RE: Regency at River Valley Lars Anderson Subject: Regency at River Valley- Revised I have reviewed the proposed project for site access with Caleb Hood of the Planning Department. In order to provide site access to meet the requirements of the International Fire Code three modifications will have to be done to the proposed plan. 1. A 26' wide emergency access road will have to be provided on the Southeast comer of the project leading out onto Alleys Way. The primary access and the recommended secondary access point must be separated by a minimum of 600' on your project. Note: The two access points must be separated by a minimum distance of V2 the diagonal measurement. In the case of Regency at River Valley that measurement is approximately 1200'. 2. For the same reasons as stated above, the project will have to be connected at two points to public roads to serve the project. One connection point will have to be to Eagle Rd. via River Valley Street on the West end of the project. A second connection point to the project will have to be from the intersection of Alleys Way and River Valley, with Alleys Way/Records Drive extending either to the North to Ustick or to the South to Fairview. 3. Because of concerns associated with congestion on Eagle Rd. the second point of access mentioned above will have to be provided before the 204 units can be built. The project could be conditioned to limit construction to 100 units until a second point of access can be placed in service meeting the requirements as outlined in comment one. Joe Silva Fire Marshal Meridian Fire From: Lars Anderson [mailto:lars.anderson@bachhomes.net] Sent: Wednesday, March 05, 2008 3:00 PM To: Joe Silva CC: sstanfield@mseng.us Subject: Regency at River Valley 3/6/2008 Page 2 of 2 Mr. Silva - I am checking in with you to see if you have had the opportunity to review our site plan again and reconsider the fire access issues. We have reviewed the ACHD standards for intersections and I have attached a table (AASHTO) that shows we would need 250 feet from the proposed intersection to the access point on Alley's Way. We only have 134 feet of property that fronts Alley's Way. Therefore we cannot comply with the request for an additional access without violating the standards. If you have an opinion on this subject, we would greatly appreciate a reply in that we are in town tomorrow (Thursday). We are trying to meet with staff on Thursday afternoon and your comments would help us in discussing this matter. Thank you, Lars Lars Anderson Bach Homes, L.L.C. Project Manager (801) 567-3029 (Direct Line) (801) 566-2224 (W) (801) 566-2203 (F) lars.anderson(2abachhomes.ne 3/6/2008