Loading...
HomeMy WebLinkAboutACHD Transmittal (A-2021-0055)Applicant name:WESLEY STEELE, W.A. STEELE, ARCHITECT Phone: Applicant address:3661 W. BISMARK DR, MERIDIAN, ID 83646 Email:wasarch@gmail.com Owner name:WESLEY STEELE, W.A. STEELE, ARCHITECT Phone:Fax: Owner address:3661 W. BISMARK DR, MERIDIAN, ID 83646 Email:wasarch@gmail.com Administrative Applicant Information Type of Review Requested File number:A-2021-0055 Assigned Planner: Related Files: Subject Property Information Location/street address:2835 E LANARK ST Assessor's parcel number(s):R6510590070 Township, range, section:3N1E8 Agent name (e.g. architect, engineer, developer, representative):SPENCER HILL Firm name:HILL BUILDINGS LLC Phone:Fax: Address:2700 E LANARK ST Email:spencer@advancedsign.com Contact name:Phone:Fax: Contact address:Email: Project/Application Name:Advanced Sign New Building - DES, CZC Description of Work:New 62,500 sf building on four lots per submitted narrative Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Alternative Compliance - ALT:UNCHECKED Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:No Does your project contain new construction and/or modifications to an existing building or the site?: Yes Design Review - DES:CHECKED Private Street - PS:UNCHECKED Vacation - VAC:UNCHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2021-0172 TYPE OF USE PROPOSED Residential:UNCHECKED Office:UNCHECKED Commercial:UNCHECKED Employment:UNCHECKED Industrial:CHECKED Single-Family Detached:UNCHECKED Single-Family Attached:UNCHECKED Townhouse:UNCHECKED Duplex:UNCHECKED Multi-Family:UNCHECKED Vertically Integrated:UNCHECKED PUBLIC WORKS INFRASTRUCTURE Does this project require the extension of public infrastructure?:No I agree to upload required checklist items for review:UNCHECKED I acknowledge deferral of the required checklist items, may require additional review time: UNCHECKED I agree to upload required checklist items with the building application:UNCHECKED PROPERTY INFORMATION General Location:SE corner of Lanark and Olson Current Land Use:I-L Total Acreage:4.929 Prior Approvals (File Numbers):none ZONING DISTRICT(S) R-2:UNCHECKED R-4:UNCHECKED R-8:UNCHECKED R-15:UNCHECKED R-40:UNCHECKED Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 C-N:UNCHECKED C-C:UNCHECKED C-G:UNCHECKED L-O:UNCHECKED M-E:UNCHECKED H-E:UNCHECKED I-L:CHECKED I-H:UNCHECKED O-T:UNCHECKED TN-C:UNCHECKED TN-R:UNCHECKED County:UNCHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):03/03/2021 Landscape Plan Date (MM/DD/YYYY):02/22/2021 Elevations Date (MM/DD/YYYY):03/03/2021 Percentage of Site Devoted to Building:23.5 Percentage of Site Devoted to Landscaping:10 Percentage of Site Devoted to Paving:56.5 Who will own and Maintain the Pressurized Irrigation System in this Development:Hill Buildings LLC Irrigation District:Nampa Meridian Primary Irrigation Source:Snyder Lateral Proposed Building Height:39 Existing Floor Area (If Applicable):0 Gross Floor Area Proposed:62500 Number of Standard Parking Spaces Provided:152 Number of Compact Parking Spaces Provided:0 Number of Employees:125 Number of Residential Units:0 Minimum Square Footage of Living Area (Excluding Garage):0 In Reclaimed Water Buffer:No QUALIFYING OPEN SPACE Open Grassy Area (min. 50' x 100'):UNCHECKED Community Garden:UNCHECKED Ponds or Water Features:UNCHECKED Plaza:UNCHECKED Additions to Public Park:UNCHECKED Collector Street Buffer:UNCHECKED Arterial Street Buffer:UNCHECKED 8' or 6' Wide Parkways:UNCHECKED 10' Parkway Along Arterials:UNCHECKED 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 5 Stormwater Detention Facility:UNCHECKED QUALIFYING SITE AMENITIES Clubhouse:UNCHECKED Fitness Facilities:UNCHECKED Enclosed Bike Storage:UNCHECKED Public Art:UNCHECKED Picnic Area:UNCHECKED Additional 5% Open Space:UNCHECKED Communication Infrastructure:UNCHECKED Dog Owner Facilities:UNCHECKED Neighborhood Business Center:UNCHECKED Swimming Pool:UNCHECKED Children's Play Structure:UNCHECKED Sports Courts:UNCHECKED Pedestrian or Bicycle Circulation System:UNCHECKED Transit Stop:UNCHECKED Park and Ride Lot:UNCHECKED Walking Trails:UNCHECKED APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Wesley Steele 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 7 3/8/21 Meridian Planning & Zoning Dept 33 E Broadway Ave Meridian, Idaho 83642 RE: DESIGN REVEW & CZC APPLICATION FOR ADVANCED SIGNS NEW BUILDING To Whom it May Concern, Please find enclosed our Design Review and CZC application for a new 62,500 square foot, two story, light industrial building to be located on four existing lots of Olson and Bush Subdivision Blocks #2 & 3 on E Lanark St. containing approximately 5 acres. This project will ultimately combine Lots 1 and 2 of Block 2 and Lots 9 and 10 of Block 3 into a single lot prior to completion of the proposed building. The building is being designed as a multi-tenant building capable of division into three tenant suites. Two of the three suites will be occupied by Advanced Signs and their sister company Decalcomania with the third suite available for lease. Advanced Sign is a sign manufacturing company presently located a few lots west of the proposed site at 2700 E Lanark St, Meridian, ID 83642. Decalcomania is a ‘vehicle wrap’ company providing vehicle signage. The building will be a tilt-up concrete structure with parapet low slope roof, storefront windows and entry doors and a combination of at grade and dock high doors. The exterior architectural character includes four colors of textured coating to soften the exterior look similar to a stucco finish, multiple sizes of recessed rustication reveals both horizontal and vertical to accentuate th e fenestration and color transitions. The main entrances to the tenant suites are articulated by modulating parapet heights and horizontal wall plane changes creating recessed entries with canopies above as well as up down accent lighting on the main entry columns. The building includes windows on all elevations as well as multiple color changes. Upper level windows on the main entrance also contain a horizontal canopy mullion to add additional relief and shadow to the elevation. All mechanical equipment is expected to be roof mounted away from the building edge and screened from view by the raised parapets. The site has been designed to separate auto parking from the main truck traffic. The existing sidewalk along Olson will be extended to the southern property boundary and three new curb return access drives have been proposed with one on Lanark and two on Olson. The parking area has been designed to contain 157 parking places as the two suites will employ approximately 125 people. The pedestrian sidewalk along Olson extends through the landscape adjacent to an accessible parking stall and connects to the main entry sidewalk along the front elevation of the building. A seven-place bicycle rack has been located near the center of the front elevation adjacent to the Advanced Signs employee entrance. The site is proposed to be fully landscaped and meets the City’s landscape criteria for street and parking trees. A covered employee patio is proposed on the south east corner of the building as Advanced Signs New Building Design Review and CZC Application P a g e | 2 an additional amenity for the building users. A covered parking canopy is proposed on the south side of the loading area to protect the commercial vehicles that remain at the site. The loading dock area on the south side of the building will be fenced with a 6’ chain link security fence. There will be an 8’ high concrete screen wall that obscures much of the loading dock area from Olson as well as the trash receptacles with rustication to match the building. The screen wall is also the backdrop to the employee patio. We believe that the proposed project will complement the existing industrial development and look forward to your approval of our applications. If you have any questions or comments regarding this application, please let me know. Respectfully, Wesley Steele - Owner steele architecture S43°56'40"E 27.92'S00°18'48"E 251.93' S 2 2 °4 3 '0 2 "E 1 1 1 .5 3 'S 1 8 °2 9 '0 3 "E 4 9 .9 1 'S00°20'28"E 166.35' N00°38'22"W 85.78'S89°37'03"W 119.52'N01°24'23"E 240.25' N01°28'03"E 273.23'S88°35'35"E 328.00'S89°54'40"E 300.96'SNYDER LATERAL40'-0" NEW BUILDING 1ST FLOOR 50,000 SF 2ND FLOOR 12,500 SF TOTAL BUILDING 62,500 SF19'-0"27'-6"5'-0"9'-0"(6) @ 9' = 54'-0"9'-0"(8) @ 9' = 72'-0"(7 ) @ 9 ' = 6 3 '-0 " 9 '-0 "(7 ) @ 9 ' = 6 3 '-0 "10'-6"19'-0"25'-0"19'-0"(8 ) @ 9 ' = 7 2 '-0 "25'-0"36'-0"(20) @ 10' = 200'-0"30'-0" 160'-3"36'-1"12'-0"19'-0"25'-0"19'-0"19'-0"25'-0"19'-0"14'-0"30'-0"34'-0"12'-6"(8) @ 9' = 72'-0"9'-0"(8) @ 9' = 72'-0"9'-0"(8) @ 9' = 72'-0"12'-6"25'-5"29'-4"(11) @ 9' = 99'-0"LOADING DOCK RAMP DOWN RAMP UP TO AT GRADE OH DOORS LOADING DOCK RAMP DOWN RAMP UP TO AT GRADE OH DOORS 9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"9'-0"10'-3"5'-0"4'-0"48'-0"24'-0"30'-0"4 2 '-0 "11'-4"E.01 E.01 E.01 E.01 E.02 E.02 E.03 E.06 E.04 E.05 E.05 E.05 E.05 03.21 03.21 03.21 03.22 03.22 21.04 26.20 32.01 32.01 32.01 32.01 32.02 32.02 32.02 32.03 32.03 32.03 32.03 32.03 32.05 32.05 32.05 32.05 13.21 13.20 32.06 32.06 32.06 32.06 32.07 32.07 32.07 32.08 32.08 32.08 32.09 32.09 32.09 32.09 32.09 32.09 32.10 32.10 32.12 32.13 32.15 32.15 32.16 32.16 32.16 32.16 32.16 32.16 32.16 32.24 32.11 32.11 40 YD DUMPSTERS 05.05(12) 05.05 05.05 05.05 05.05 05.05 20' FIRE LANE 20' FIRE LANE E.07 E.07 E.07 E.01 8 YD DUMPSTERS SHEET TITLE CLIENT / PROJECT INFORMATION PROJECT NO: DRAWN BY: CHECKED BY: SEAL THIS DRAWING WAS PREPARED BY STEELE ARCHITECTURE FOR A SPECIFIC PROJECT, TAKING INTO CONSIDERATION THE SPECIFIC AND UNIQUE REQUIREMENTS OF THE PROJECT. REUSE OF THIS DRAWING OR ANY INFORMATION CONTAINED IN THIS DRAWING FOR ANY PURPOSE IS PROHIBITED UNLESS WRITTEN PERMISSION FROM BOTH SA AND SA'S CLIENT IS GRANTED. SHEET # PO BOX 245 | EAGLE, ID 83616 208.871.7176 NOT FOR CONSTRUCTION PRELIMINARY 3/2/2021 6:19:29 PM2883 E LANARK ST MERIDIAN, ID 83642 NEW BUILDING 20016 WAS WAS A1-01A1-01 ARCHITECTURAL SITE PLAN NORTH1" = 20' 20100 6040 FEET SCALE: 1" = 20'-0" ARCHITECTURAL SITE PLAN1 TRASH ENCLOSURE (2) 40 YD & (2) 8 YD DUMPSTERS BEHIND 8' SCREEN WALL - NO GATES BICYCLE PARKING 7 PROVIDED PARKING PLACES REQUIRED 32 TOTAL (62,500 / 2,000) PARKING PLACES PROVIDED 152 TOTAL - 125 STANDARD - 7 ACCESSIBLE - 0 COMPACT - 20 COVERED SIDEWALK AREA 7,382 SF (3%) TOTAL PARKING & DRIVE AREA 121,277 SF (56.5%) STREET TREE REQUIREMENT (21) REQUIRED - (21) PROVIDED, REFER TO LANDSCAPE PLAN TOTAL LANDSCAPE AREA 20,905 SF (10%) UNDEVELOPED AREA 15,186 SF (7%) SNYDER LATERAL BUILDING AREA 62,500 SF TOTAL BUILDING - 50,000 SF (1ST FLOOR) 23.5% - 12,500 SF (2ND FLOOR) TOTAL SITE AREA 214,750 SF (4.929 ACRES) ZONING DISTRICT I-L ASSESSOR'S PARCEL #R6510590070 / R6510590060 / R6510590050 / R6510600040 (FOUR LOTS TO BE COMBINED INTO ONE) SITE PLAN DATASITE PLAN GENERAL NOTES 1. THIS SITE PLAN IS PROVIDED FOR GENERAL COORDINATION PURPOSES. REFER TO AND COORDINATE WITH RESPECTIVE CIVIL, LANDSCAPE, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFIC INFORMATION. 2. COORDINATE WITH CIVIL DRAWINGS FOR ALL UTILITY LOCATIONS, FINAL GRADING AND DRAINAGE REQUIREMENTS. 3. CONTRACTOR TO VERIFY ALL LOCATIONS AND DIMENSIONS IN FIELD. 4. REFER TO GEOTECH ENGINEERING REPORT FOR SOIL BEARING PRESSURES, EXISTING SOIL CONDITIONS AND CONSTRUCTION CONSIDERATIONS. 5. REFER TO LANDSCAPE DRAWINGS FOR PLANTING INFORMATION 6. REFER TO ELECTRICAL AND BUILDING ELEVATIONS FOR BUILDING MOUNTED EXTERIOR LIGHTING. 7 IF REQUIRED, NEW FIRE HYDRANT LOCATIONS TO BE VERIFIED WITH FIRE DEPARTMENT. KEYNOTES - SITE PLAN #DESCRIPTION 32.07 CURB RAMPS COMPLYING WITH ICC/ANSI SECTION 406 AT ALL ACCESSIBLE PARKING 32.08 CURB RETURN ACCESS WITH ACCESSIBLE RAMP, REFER TO CIVIL 32.09 NEW SIDEWALK WITH TURNDOWN EDGE, REFER TO CIVIL 32.10 CAST IN PLACE CONCRETE STAIR WITH GALVANIZED PIPE INDUSTRIAL SAFETY GUARDRAIL AND HANDRAIL 32.11 TRENCH DRAIN FOR RECESSED LOADING DOCK, REFER TO CIVIL 32.12 SERPENTINE BIKE RACK. DERO RIBBON RACK 'RB-05', EMBED IN CONCRETE WALK 32.13 6' CHAIN LINK FENCING 32.15 MANUAL SWING CHAIN LINK GATE 32.16 LANDSCAPE PLANTER TYPICAL, REFER TO LANDSCAPE PLAN 32.24 GRAVEL GROUND COVER BY EARTHWORK CONTRACTOR, APPLY GROUND STERILIZATION PRIOR TO INSALLATION E.01 PROPERTY LINE E.02 EXISTING SIDEWALK E.03 EXISTING ACCESSIBLE RAMP E.04 EXISTING FIRE HYDRANT E.05 EXISTING CURB E.06 EXISTING STREET LIGHT E.07 EXISTING FENCE KEYNOTES - SITE PLAN #DESCRIPTION 03.21 SITE CAST TILT UP CONCRETE DOCK WALL WITH GALVANIZED PIPE GUARDRAIL 03.22 SITE CAST TILT UP CONCRETE SCREEN WALL 8' ABOVE FINISH GRADE 05.05 6"Ø x 48" HIGH CONCRETE FILLED PIPE BOLLARD, PRIME AND PAINT SAFETY YELLOW OR RED 13.20 PEMB COVERED PARKING STRUCTURE 13.21 PEMB COVERED PATIO STRUCTURE 21.04 FIRE DEPARTMENT CONNECTION POINT 26.20 PROPOSED ELECTRICAL TRANSFORMER LOCATION, REFER TO ELECTRICAL 32.01 ASPHALT PAVING, REFER TO CIVIL 32.02 CONCRETE PAVING, REFER TO CIVIL 32.03 CONCRETE CURBING, REFER TO CIVIL 32.05 STANDARD PARKING PLACE 3" WIDE STRIPING 9' x 19' 32.06 ACCESSIBLE PARKING PLACE WITH 3" WIDE STRIPING, PAINTED SYMBOL, VERTICAL IDENTIFICATION SIGN PRINT RECORD REV DESCRIPTION DATE A ISSUED FOR DR & CZC 03/03/2021