Loading...
Applicant proposed changes to Conditions of Approval'A.. 10-1 LAND PLANNING F101 CIVIL ENGINEERING F LANDSCAPE ARCHITECTURE WATER RESOURCES 1173 East Winding Creek Drive Eagle, ID 83616 PH 208/246.8300 FX 208/246.8320 www.wrgdesign.com ©�0 D E S I G N I N C. MEMORANDUM To: Honorable Mayor and Meridian City Council Via: Hand Delivered From: Megan Johnson, AICP Senior Planner Date: July 17, 2007 Project: Meadow Lake Village North (Phase III) WRG#: TCH6223 RECEIVE JUL 17 2007 city ofivlelidian City Clerk Moo Re: Proposed Changes to Conditions of Approval - Meadow Lake Village North (PP-07-009, CUP-07-008, and MI-07-006) 1.2.6 The residential setbacks for the proposed subdivision shall be as follows: Setbacks Street to Living Area** 10 Street to Front -Facing 20 Garage** Side Entry Garage** 15 Street Side** 10 Side* 5 / story Rear* 12 Minimum Lot Size 5,250 Maximum Building Height 35 Minimum Street Frontage 40 Street Frontage on Cul-de- 30 sac * Measured from property line ** Measured from back of sidewalk 1.2.11 Maintenance of all common areas shall be the responsibility of the Meadowlake Village North Homeowners Association or in the absence of an HOA the existin Meadow Lake Village ownership shall maintain all common areas. 2.30 streetlights, on 30'pele shall be required E)n subdivision entrances and eelleetEw fea4way-s:Design of the streetlights shall be approved by the Public Works Department. Decorative lights require a streetlight agreement on file with Public Works prior to activation. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants, and no further than 400' distance in between locations. Final design locations and quantity are 1-01 LAND PLANNING FU CIVIL ENGINEERING F LANDSCAPE ARCHITECTURE WATER RESOURCES 1173 East Winding Creek Drive Eagle, ID 83616 PH 208/246.8300 FX 208/246.8320 D E S I G N I N C. determined after power designs are completed by Idaho Power Company. The street light contractor shall obtain approval from the Public Works Department, and permit from Building Department prior to commencing installations. 3.9 To increase emergency access to the site a minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. The two entrances should be separated by no less than 1/2 the diagonal measurement of the full development. i4} } can —shag provide a— stub —street within tE}�e 3.12 Commercial and office occupancies will require a fire -flow consistent with the International Fire Code to service the proposed project. Fire hydrants shall be placed per Appendix D. (Commercial Only). 3.13 Maintain a separation of 5' from the building to the dumpster enclosure. (Commercial Only) 3.14 Provide a Knox box entry system for the complex prior to occupancy. (Commercial Only) 3.14.1 The first digit of the office suite shall correspond to the floor level. (Commercial Ong) 3.17 All aspects of the building systems (including exiting systems), processes, and storage practices shall be required to comply with the International Fire Code. (Commercial Onlvl 3.19 Provide exterior egress lighting as required by the International Building & Fire Codes. (Commercial Only) 3.20 There shall be a fire hydrant within 100' of all fire department connections. (Commercial Onlyl Z M-01 " =__ 4.1 The proposed development shall limit landscaping shrubs and bushes to species that do not exceed two feet in height. Trees shall have a canopy of no less than six feet. (Commercial Only) www.wrgdesign.com