Loading...
HomeMy WebLinkAboutMarlin Sub CUP 02-010April 29, 2002 CUP 02-010 MERIDIAN PLANNING & ZONING MEETING APPLICANT Winston Moore May 2, 2002 ITEM NO. 8 REQUEST Public Hearing - Request for a Conditional Use Permit for a Planned Development for single-family residential lots in a proposed R-4 zone for proposed Marlin Subdivision - north of 1-84 and east of South Under Road AGENCY COMMENTS CITY CLERK: CITY ENGINEER: CITY PLANNING DIRECTOR: CITY ATTORNEY CITY POLICE DEPT: CITY FIRE DEPT: CITY BUILDING DEPT: CITY WATER DEPT: CITY SEWER DEPT: SANITARY SERVICE: MERIDIAN SCHOOL DISTRICT: MERIDIAN POST OFFICE: ADA COUNTY HIGHWAY DISTRICT: CENTRAL DISTRICT HEALTH: NAMPA MERIDIAN IRRIGATION: IDAHO POWER: US WEST: INTERMOUNTAIN GAS: OTHER: See attached Comments See attached Comments "No Comment' "O.k." See attached Comments Materials presented at public meetings shall become propmty of the City of Meridian. NL&YOR Robert D. Corfie CITY COUNCIL MEMBERS Tammy deWeerd Keiflx Bird Cherie McCandless William L. M. Naxy HUB'OF TREASURE VA LLEY A Good Place to Live CITY OF MERIDIAN 33 EAST IDAHO MERIDIAN, IDAHO 83642 (208) 888-4433. FzLX (208) 887-4813 City Clerk Office Fax (208) 888-4218 O -oZ oZ DEP.MITMENT (208) 884-5533. F.~X 888-6854 MEMORANDUM: April 30, 2002 To.' From: Re: Mayor, City Council and Planning & Zoning Commission Brad Hawkins-Clark, Planner ~Q- Bruce Freckleton, Senior Engineering Tech ~ Marlin Subdivision RECEIVED ,'WAY - 12002 CITY OF MERIDIAN CITY CLERK Annexation and Zoning of 40.36 Acres fxom RUT (Ada County) to R-4 (Low Density Residential), by Winston Moore (File No. AZ-O2-OOD. Preliminary Plat Approval of 152 Residential Building Lots and 6 Other Lots on 40 Acres on Land Requested to be Rezoned to R-4, by Winston Moore (File No. PP-02-O08). A Conditional Use Permit for a Planned Development on 40 Acres to Allow Reduced Lot Sizes, Reduced Frontage Requirements, Reduced Setbacks and Reduced Home Sizes, by Winston Moore (File No. CUP 02-010) We have reviewed the aforementioned applications and now offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATIONS SUMMARY The Applicant, Winston Moore, has requested the annexation and zoning of a 40.36 acre infill parcel of land on the east side of Linder Road, north ofi-84. The land is presently vacant pasture and is zoned RUT (Ada County). The Applicant has requested that all of the subject property be zoned to R-4. The Applicant's preliminary plat request is for 152 detached, single family building lots, two (2) large common area lots, a micropath lot, and three (3) landscaped lots. The proposed density is 3.80 d.u./acre. The plat includes 4.17 acres of usable open space, or 10.44% of the gross land area. An additional 2.78 acres of the site (6.9%) is required landscaped area. Two of the subdivision streets (Rainbow Trout Ave. and Brook Trout Dr.) are proposed as 29-foot street sections with restricted parking. No attached dwelling units are being proposed within the subdivision-all are detached. AZ-02-007, pP --02-008, C~-OIO Marli~ Sub. A~ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 2 The Applicant has also requested approval of a Conditional Use Permit for a Planned Development (PD) in order to allow alternative development standards, including reduced side building setbacks, reduced lot sizes, reduced lot frontages and reduced dwelling sizes. The following is a side-by-side comparison of the City's minimum R-4 requirements and the reduced requirements that have been proposed by the Applicant through the PD application: Setbacks- City Requirements (R-4) Front: 20' Rear: 15' Side: 5 '/per story Street side: 20' Proposed Setbacks Front: 20' Rear: 15' Side: 5' (no additional setback per story) Street side: 20' Lot Size- City Requiremems R-4 zone: 8,000 sq.ft. per dwelling unit Proposed Lot Sizes 5,000 sq. ft. per d.t~ Lot Frontage-City Requiremems 80'minimum Proposed Frontage 50' minimum House Size- City Requiremems 1,400 sq. ft. min.* Proposed Minimum House Sizes 1,000 sq. ft. min. The Applicant is also proposing two narrow streets at a 29-foot street section, which varies from the standard 36-foot width. All street sections would still be placed within 50 feet of-public right-of-way. The reduced street sections are not a part of the PD request as the City's Subdivision Ordinance allows any public streets that comply with ACHD policies (Ord. 12-4- 2.C.1). The 29-foot wide section is allowed under ACHD's policy for streets where the average trips per day does not exceed 1,000. LOCATION The property is generally located at the ½ mile between Franklin and Overland Roads on the east side of S. Linder Road. The property extends approximately ¼ mile to the east and is within Section 13 ofT. 3N, R. 1W. SURROUNDING PROPERTIES North: The Landing Subdivision #7, zoned R-4. South: 1-84 abuts the emire south boundary. Vacant land, zoned I-L, is directly south ofi-84. East: The Landing Subdivision #9 and #10, zoned R-4. West: Primrose Subdivision, zoned R-1 (Ada County). The majority of the lots in this county subdivision range between .5 to 1 acre in size. AZ.O2-O07, pp --02-008, CUP02-O 10 Maflm Sub.AZ. PP. CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 3 ANNEXATION & ZONING ANALYSIS According to Ordinance 11-15-11, General Standards Applicable to Zoning Amendments, both the P&Z Commission and Council are required "to review the particular facts and circumstances of each proposed zoning amendment in terms of the following standards and shall fred adequate evidence answering the following questions about the proposed zoning amendment." The following is the list of standards found in 11-15-11 and analysis by staff.' "A. Will the new zoning be harmonious with and in accordance with the Comprehensive Plan and, if not, has there been an application for a Comprehensive Plan amendment; Staff f'mds that the requested zoning designation of R-4 is harmonious with and in accordance with the adopted Comprehensive Plan and Generalized Land Use Map, which designates the land to be "Mixed/Planned Use Development". This classification allows for single family residential uses, but only under a Planned Development application. Existing single family uses abut the subject parcel on three (3) sides. The Generalized Land Use Map does show a potential park and school site in this location, symbols which are intended to be "floating" in nature and would be encouraged should either the Parks & Recreation Department or school district require facilities in this area. However, to Staff's knowledge, neither the Parks & Recreation Department nor the school district have expressed a need or interest for facilities in this area. Has there been a change in the area or adjacent areas which may dictate that the area should be rezoned. For example, have the streets been widened, new railroad access been developed or planned or adjacent area being developed in a fashion similar to the proposed rezone area; Staff finds that the adjacent Landing Subdivision, platted and constructed within the past six (6) years with standard City and ACHD improvements, would dictate that the abutting property be similarly zoned and developed. The Hark's Comer commercial development at the southwest comer of Linder and Franklin, about lA mile to the north, also provides neighborhood-type services within a reasonable distance fi:om the site. The Comprehensive Plan also encourages infill parcels to be annexed and developed. Will the proposed uses be designed, constructed, operated and maintained to be harmonious and appropriate in appearance with the existing or intended character of the general vicinity and that such use will not change the essential character of the same area; AZ-02-007, pP -02-008, CUP02-010 Marlin Sub. AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 4 Staff finds that the general vicinity provides a mix of services and standard City- size and rural residential lots. The intended character of the vicinity, as noted on the Generalized Land Use Map, is for a mix of uses, including housing, and it is assumed that other compatible, residential services would be permitted in the area as well. Staff finds that the proposed uses can be designed and constructed in a manner that will be harmonious with and appropriate in appearance with the existing and intended character of the surrounding area. Will the proposed uses not be hazardous or disturbing to existing or future neighboring uses; The Commission and Council should rely on public testimony to determine whether or not the proposed use will be disturbing or hazardous to the neighboring uses. Staff does not anticipate that the proposed uses will be hazardous or disturbing to future or existing neighbors. Will the area be served adequately by essential public facilities and services such as highways, streets, police and fire protection, drainage structures, refuse disposal, water, sewer or that the person responsible for the establishment of proposed zoning amendment shah be able to provide adequately any of such services; Staff finds that the subject property will be served adequately by all essential public facilities and services, assuming the Meridian Fire Department responds favorably and considers this a serviceable area. The Ada County Highway District staff has recommended approval of the project. Linder Road, Franklin to Cherry Lane, is scheduled for construction in 2007 (or later) as a 3-lane urban street. Will not create excessive additional requirements at public cost for public facilities and services and will not be detrimental to the economic welfare of the community; Staff finds that there will not be additional requirements at public cost and that the annexation and zoning will not be detrimental to the community's economic welfare. Gw Will the proposed uses not involve uses, activities, processes, materials, equipment and conditions of operation that will be detrimental to any persons, property or the general welfare by reason of excessive production of traffic, noise, smoke, fumes, glare or odors; Staff finds that the proposed uses will create additional traffic, especially on Linder Road. However, staff does not believe that the increase in traffic will be excessive. ACHD staff have determined that the existing road system should AZ-02-007, Pp -4)2-00~ CUP02-010 Marlin Sub. AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 5 adequately accommodate the new traffic. Staff does not anticipate that the proposed development will generate traffic, noise, smoke, odors or other nuisances that would be detrimental to the general welfare of the surrounding area. He Will the area have vehicular approaches to the property which shall be so designed as not to create an interference with traffic on surrounding public streets; Staff f'mds that the proposed vehicular approach on Linder Road should not appreciably interfere with traffic on the surrounding streets, beyond which the roadway can handle. The existing stub street fxom The Landing Subdivision, W. Verbena Drive, will create additional traffic, but the majority of the traffic is anticipated to be westbound out of the subdivision, not through The Landing. Linder is a two-lane roadway with curb, gutter and sidewalk along the majority of the east side between the subject parcel and Franklin Road. A future overpass is planned but not scheduled, so all Linder traffic exiting the subdivision will be northbound only for the foreseeable future. Ada County Highway District's comments should be considered when making this finding. Will not result in the destruction, loss or damage of a natural or scenic feature of major importance; and Staff f'mds that no natural or scenic features of major importance will be lost or damaged by approval of this annexation request. Is the proposed zoning amendment in the best interest of the City of Meridian. (Ord. 592, 11-17-1992)" Staff finds that the annexation of this property would be in the best interest of the City by providing a variety of housing types and lot sizes, providing a high percentage of improved open space for future city residents, an innovative subdivision layout, and the development of an infill parcel of land. ANNEXATION AND ZONING COMMENTS The legal description submitted with the application doesn't include the adjacent interstate right-of-way per the requirements of the City of Meridian and State Tax Commission. Please submit a new legal description to the Public Works Department that includes all of the adjacent interstate right-of-way prior to the applications being heard by the Meridian City Council. 2. The requested zoning of R-4 is compatible with the City Comprehensive Plan and the Meridian Zoning Ordinances. AZ-02.4)07, pp -02-008, CUP02-010 Marlin Sub.AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 6 3. The subject property is within the Urban Service Planning Area. Essential City services are available to the subject propcrty~ Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 5-7-517. Wells may be used for non-domestic purposes such as landscape irrigation. 5. A Development Agreement will not be required as part of this annexation request. PRELIMINARY PLAT FINDINGS AND REQUIREMENTS Sections 12-3-3 J.2 and 12-3-5 D read as follows: "In determining the acceptance of a proposed subdivision, the Commission/Council shall consider the objectives of this title and at least the following: a. The conformance of the subdivision with the Comprehensive Development Plan; As noted above, staff finds that the subdivision appears to be in conformance with the Comprehensive Plan. b. The availability of public services to accommodate the proposed development; Staff finds that public services are available to accommodate the proposed subdivision. c. The continuity of the proposed development with the capital improvement program; Staff f'mds that the subdivision will not require the expenditure of capital improvement funds. d. The public financial capability of supporting services for the proposed development; Staff finds that the development will not require major expenditures for providing supporting services. e. The other health, safety or environmental problems that may be brought to the Commission's attention. Staff finds that there should not be any other health, safety or environmental problems associated with this subdivision that should be brought to the Council or Commission's attention. AZ~2-007, PP -02-008, CUP02-010 Marlin Sub. AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 7 ADDITIONAL CONSIDERATIONS Block Length: The preliminary plat has two blocks (Block 1 and 7) that exceed the 1,000 foot maximum block length (MCC 12-4-5), as measured along the rear lot lines. However, because this plat is part of a PD and because the lengths are unavoidable due to existing adjacent conditions, Staff recommends they be allowed to exceed this section of Code without the need for a variance application. House Size Dispersion: Ordinance 11-10-4.C requires that "all single family detached houses in the R-8 district below 1,301 square feet shall be interspersed uniformly through the entire development." This ordinance is intended to address non-Planned Development plats in the R-8 or R-15 zones where a mix of house sizes are allowed outright under the code. Even though the subject application is proposing an R-4 zone (which is not addressed in Ord. 11- 10-4.C), Staff feels this ordinance has relevance since a mix of house sizes under 1,301 square feet are being proposed. As submitted, the plat proposes four (4) different minimum house size groups (see the "House Square Footage Map" in the CUP/PD application), all of which are contiguous blocks and not evenly dispersed through the development. However, there is only a 300 square foot difference between the smallest category (1,000 sq. ft.) and the largest category (1,300 sq. ft.). Given such a small size difference, Staff feels the requirement to evenly disperse the houses may be less important than if the size difference were greater than 300 square feet. The Commission and Council should take this issue under advisement when reviewing the plat. Fence/Common Lot Waiver: In order to allow one of Staff's recommendations below (see Item #5), the P&Z Commission and Council will need to approve a waiver to Ordinance 12- 13-10-2, which prohibits fences within required street buffers. In order to maximize the sound mitigation ofi-84 (by providing a fence on top of the berm), Staff feels such a waiver is justified. SITE SPECIFIC COMMENTS (Preliminary Plat) Sanitary sewer service to this site shall be via an extension of the existing sewer in Linder Road. Applicant will be responsible to construct the sewer mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Sewer manholes are to be provided to keep the sewer lines on the south and west sides of the centerline. Domestic water service to this site shall be via new main extensions fi:om the existing main in Linder Road and W. Verbena Drive. Applicant will be responsible to construct water mains to and through this proposed development, including the Linder frontage. Subdivision designer to coordinate main sizing and routing with the Public Works Department. AZ412-007, PP--02-008, CUPO2-010 Marlin Sub. AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 8 No phase lines are shown on the Preliminary Plat map. If the developer intends to phase construction, the Applicant shall submit a revised Preliminary Plat at least 10 days prior to the next public hearing showing any proposed phase lines and numbers. Ordinance 12-10-5.A, Minimum House Sizes Shown on Plat, requires that "all new residential housing development plats shall have the individual lots marked showing the minimum size house that can be constructed thereon, and no plat shall be recorded henceforth without such indication clearly shown thereon." Applicant shall submit a revised Preliminary Plat at least 10 days prior to the next public hearing complying with this ordinance. o The cross-section of the 1-84 landscape buffer submitted with the Landscape Plan (Sheet CUP-C) proposes a 6-foot vinyl fence on top of an 8-foot berm. Assuming rear lot line fences will be constructed, this will result in a 26-foot wide "tunnel" and secluded area between the residential fences and the subdivision vinyl fence. Staff does not support this design. The Applicant shall submit a revised cross-section of the 1-84 berm eliminating the secluded area and also demonstrate how the drainage will be handled to avoid the berm run-offwater collecting in the rear yards of residences within Block 7. Staff recommends a waiver be granted to allow the 1-84 fence to be placed within the 1-84 buffer. Staff does not support a reduction of the 50-foot wide buffer nor allowing the residential lots to encroach into this common lot. We recommend any fence within Lot 1, Block 7 be situated a minimum of 35 feet fi:om the 1-84 right-of-way and trees be planted at a density of one tree per every 25 feet of fi:ontage. o A detailed fencing plan shall be submitted with each Final Plat application. Any proposed fencing adjacent to Lot 6, Block 3 shall be clear-vision. If solid fencing is used, it shall be a maximum of 4-feet in height. Staffdiscourages the use of chain link fencing adjacent to the park. The NMID allows fencing within their Kennedy Lateral easement under existing License Agreement No. 97009476. However, the specific location of the fence is dependent upon the buildable lot rear line location. The east perimeter fence shall be placed on the rear lot lines, which will need to be determined through an encroachment agreement, per item//12 below. Lot 21, Block 1 and a portion of Lot 1, Block 1 are micropath lots. Ordinance 12-13-15-9 encourages all fences adjacent to micropath lots to be clear-vision. If solid fencing is used, it shall be a maximum of 4-feet in height. The 6-foot vinyl fence proposed in the Landscape Plan (Sheet CUP-C) adjacent to the micropath in Lot 1, Block 1 is not approved and must comply with Ordinance 12-13-15-9. The developer will be responsible for the construction of the fences adjacent to Lot 21, Block 1 and Lot 1, Block 1 and said fence restriction shall be included as a note on the Final Plats. The developer shall comply with Ordinance 12-13-10-9 on Linder Road regarding the landscaping of unimproved street right-of-way greater than 13 feet in width. Said landscaping must be installed or bonded for prior to issuance of any Certificates of Occupancy. AZaY24X~, pP-02.-00~, CUP02-OIO Marlin Sub. AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 9 10. 11. 12. 13. 14. 15. 16. The required landscaping and irrigation system on Linder Road and adjacent to 1-84 shall be installed prior to the issuance of a Certificate of Occupancy for any building on any lot created by the subdivision. All required fencing shall be installed prior to the issuance of any building permits. Landscaping and fencing must be bonded for prior to City signature on the Final Plat. The minimum number of street trees, as required by Ordinance 12-13-10-6, is not met by the proposed Landscape Plan for the Linder Road and 1-84 required buffers. Applicant shall submit detailed landscape plans with the Final Plat application that complies with this ordinance. South of W. Verbena Drive, ACHD is requiring more right-of-way on Linder Road than what is shown on the Preliminary Plat. Ordinance 12-13-10-4 requires a minimum 25- foot wide street buffer along Linder Road, beyond future right-of-way. It appears the additional right-of-way will significantly reduce the proposed buffer width to less than 10 feet at some locations. The Applicant shall address this issue at the P&Z Commission hearing and propose how adequate buffering will be provided fi.om the future overpass. The Applicant shall submit a revised Preliminary Plat showing the required Linder Road right-of-way, the new street buffer width, and any revised open space calculations. Fffieen (15) building lots within Blocks 1 and 7, adjacent to the east boundary, appear to encroach into the Kennedy Lateral easement. These lots shall be configured to the edge of easement lines unless an encroachment agreement is granted by Nampa Meridian Irrigation District. If the former is the case, create a common area lot covering the balance of the easement width, and submit a copy of said NMID agreement prior to submittal of the Final Plat application. Applicant shall clarify the requested minimum side yard setback distance. The application states 5 feet for both single and two-story but the Preliminary Plat shows 5 feet per story. A minimum 10 feet of clearance must be provided between all detached housing. The Preliminary Plat fails to show the how street drainage is being handled. Please revise the plat to show set-aside areas for drainage retention/detention. Underground pressurized irrigation must be provided to all landscape areas on site. Applicant has not indicated whether the pressurized irrigation system within this development is to be owned and maintained by an association or the Nampa & Meridian Irrigation District. If the system is being proposed as a private system, plans and specifications for the irrigation system shall be reviewed by the Public Works Department as part of the development plan review process. A draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. The City of Meridian requires that pressurized irrigation systems be supplied by a year- round source of water. Ifa creek or well source is not available, a single-point connection AZ.02-007, PP -02-008, CUIW~-010 Marlin Sub. AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 10 to the culinary water system shall be required. Ifa single-point connection is utilized, the developer shall be responsible for the paymem of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 17. Please provide a copy of the complete geotechnical engineering report to be issued by Materials Testing & Inspection by 20 March, 2002, to the Public Works Department. 18. Please revise preliminary plat note #1 to also include the rear lot lines. GENERAL COMMENTS (Preliminary Plat) Please submit a copy of the Ada County Street Name Committee's final approval letter for the subdivision name, and the lot and block numbering. Make any corrections necessary to conform. 2. Coordinate fire hydrant placemem with the City of Meridian Public Works Departmem. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. Two-hundred-fifty and one-hundred-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. The ditches to be piped should be shown on the site plans. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association, with written confirmation of said approval submitted to the Public Works Department. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Sections 9-1.4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 7. Slopes within drainage lots are not to exceed a ratio of3:l. Performance specificatiOns for the common area pressurized irrigation system shall be submitted with each Final Plat application. STANDARDS FOR CONDITIONAL USES The Commission and Council shall review the particular facts and circumstances of each P,Z-O2-Oq'/, pp-02006, CUI~2-OIO Marlh~ Sub. AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 11 proposed conditional use in terms of the following and may approve a conditional use permit if they shall fred evidence presented at the hearing(s) is adequate to establish (11-17-3): Ae That the site is large enough to accommodate the proposed use and all yards, open spaces, parking landscaping and other features as may be required by this ordinance; Staff finds that the subject property is large enough to accommodate the requested use and all other required features. Be That the proposed use and development plan will be harmonious with the Meridian Comprehensive Plan and in accordance with the requirements of this Ordinance; The current Comprehensive Plan Land Use Map designates the property as Mixed/Planned Use Development. The proposed residential uses and house types are harmonious with and in accordance with the Comprehensive Plan. The project meets the requirements and objectives of the Planned Development Ordinance. Cm That the design, construction, operation, and maintenance will be compatible with other uses in the general neighborhood and with the existing or intended character of the general vicinity and that such use will not adversely change the essential character of the same area; Assuming standard constm~o~ dust mitigation and other operation practices are followed and enforced, the proposed Marlin Subdivision is consistent with the intended character of this area. Staff typically does not consider single-family residential adjacent to single-family residential to be incompatible uses, regardless of adjacent lot sizes. Do That the proposed use, if it complies with all conditions of the approval imposed, will not adversely affect other property in the vicinity; Staffdoes not anticipate that the proposed project will have an adverse impact on the surrounding property; however, the Commission and Council should consider any testimony given at the public hearings before making this finding. See comments in "C" above. That the proposed use will be served adequately by essential public facilities and services such as highways, street, police, and fire protection, drainage structures, refuse disposal, water, sewer or that the Person responsible for the establishment of proposed conditional use shall be able to provide adequately any such services; Staff finds that the proposed development can be adequately served by the essential public facilities and services listed above. Fe That the proposed use will not create excessive additional requirements at public cost for public facilities and services and will not be detrimental to the economic AZ-02-007, pp -02-0~, CUI~02-010 Marlin Sub. AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 12 welfare of the community; Stafffinds that the proposed use would not be detrimental to the economic welfare of the community, nor would it create the need for any new facilities or services to be paid for by the public. That the proposed use will not involve activities or processes, materials, equipment, and conditions of operation that will be detrimental to any persons, property, or general welfare by reason of excessive production of traffic, noise, smoke, fumes, glare or odors; Stafffinds that no excessive traffic, noise, smoke, fumes, glare or odors will result fi.om the proposed use. Standard construction containment practices must be observed. That the proposed use will have vehicular approaches to the property which shall be so designed as not to create an interference with traffic on surrounding public streets; Staff finds that the proposed use will not create significant interference with any traffic on the surrounding public streets. The Council and Commission should refer to the ACHD report for additional information concerning this finding. That the proposed use will not result in the destruction, loss or damage of a natural, scenic or historic feature considered to be of major importance. Staffdoes not find that any natural or scenic feature will be lost, damaged or destroyed by issuance of this conditional use. ADDITIONAL CONSIDERATIONS Minimum Lot Size: The proposed minimum lot size of 5,000 square feet is a 37.5% reduction from the standard 8,000 minimum lot size in the R-4 zone. The Planned Development Ordinance (12-6-6.A.) allows the minimum lot size to be reduced below those normally required for the R-4 zone and does not establish a minimum area allowed. The proposed number of 152 single family lots is eight (8) lots below the maximum density allowed under a straight R-4 zone (without a PD) for a 40-acre subdivision. SITE SPECIFIC COMMENTS fConditionai Use Permit) Applicant shall meet all of the requirements of the preliminary plat as a condition of the Conditional Use Permit. Per Ordinance 12-6-2.A.4, all houses within Marlin Subdivision shall have at least one hundred (100) square feet of useable private open space, such as a patio or deck. AZ-02.007, PP-O2-(X}8. CUP02-010 Marlin Sub.AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 13 Staff strongly supports the two centralized and accessible open space lots. Lot 1, Block 6 is especially well sited and maximizes the open space view and usability of the 28+ lots that fxont onto the green space. One recommendation we have to improve the open space features of the subdivision is to re-configure Lot 6, Block 3 so this mini-park, or at least a view corridor into the park, is visible fxom the main Verbena Drive entrance. As currently designed, Lots 21 - 25, Block 3, block visibility into this open space area until the vehicle or pedestrian either tums north on Barracuda Avenue or travels 250+ feet east past Lot 21, Block 3. We feel it would create a benefit to the subdivision to "showcase" the open space at the main entrance offLinder Road. Staff recommends Lot 6, Block 3 be re-configured to maximize the main entrance view corridor into this open space area. At the P&Z Commission public hearing, the Applicant shall con_f'mn which net open space calculation listed on the Preliminary Plat is correct. The "Open Space Calculations" block shows 181,835 sq. ft. (10.44%) and the "Preliminary Plat Features" block shows 191,819 sq. ft. (11.01%). Please correct this discrepancy on the plat prior to the next public hearing. In either instance, the minimum 10% open space required to count as one of the project's two amenities has been met. Per Ordinance 12-6-2.A.3, at least two (2) amenities must be provided as part of every planned development. The 10+ percent open space noted in Item #3 above counts as one of the required amenities and Staff strongly supports the central location and size of this open space. However, a second project amenity must be provided. At the P&Z Commission public hearing, the Applicant shall submit in writing a description of their proposed second amenity and on which open space lot it will be sited. The Commission should consider whether the proposed amenity meets the intent of Ordinance 12-6-2.A.3 and is adequate to meet the needs of the anticipated 453 residents of this subdivision (152 d.u. x avg. household size of 2.98 persons for owner-occupied units in Meridian). Per Ordinance 12-6-8, initiation of work on Marlin Subdivision must take place within eighteen (18) months of approval, as set forth in Section 11-17-4. All development shall comply with the Americans with Disabilities Act and the Fair Housing Act. o No building permits shall be issued within the development until a Final Plat has been recorded for the subdivision. COMPREHENSIVE PLAN POLICIES The subject property is located in an area designated as Mixed Residential in the Meridian Comprehensive Plan. The 1993 Comprehensive Plan contains a variety of goals and policies that are relevant to this application. Staff has selected the following sections that most directly apply to the proposed project. Goals Section Goal 4: To provide housing opportunities for all economic groups within the community. AZ-02-~7, PP -02-008, CUI~02-010 Marlin Sub. AZ PP.CUP Planning & Zoning Commission/Mayor & City Council April 30, 2002 Page 14 Goal 8: To establish compatible and efficient use of land through the use of innovative and functional site design. Goal 8: To establish compatible and efficient use of land through the use of innovative and functional site design. Economic Development 3.1U - Approve quality housing projects that meet the needs of all economic levels. 3.2U - Encourage efforts to develop and maintain quality neighborhoods and housing... Land Use 1.10U Promote the design of attractive roadway entryway areas into Meridian which will clearly identify the community. 2.1U - Support a variety of residential categories for the purpose of providing the City with a range of affordable housing opportunities. 2.4U - Encourage sidewalks and paved streets for all existing neighborhoods... 5.9 The integrity and identity of any adjoining residential neighborhood should be preserved through the use of buffering techniques, including screen plantings, open space and other landscaping techniques. 5.12 Clustering of uses and controlled access points along arterials and collector streets will be required. Community Design 1.3 Open space areas within all development should be encouraged. 1.4 Major entrances to the City should be enhanced and emphasized. Unattractive land uses along these entrances should be screened from view. 2.3U Encourage the beautification of streets, parking lots...etc. 6.2U - Pedestrian access connectors will be required in all new development to link subdivisions together to promote neighborhood identity. 6.11U - Promote well-planned and well-designed affordable housing in all Meridian neighborhoods. Transportation Chapter 1.19U - Encourage proper design of residential neighborhoods to ensure their safety and tranquility. 1.18 - As Planned Development methods and standards are implemented by the City of Meridian, variations pertaining to planned development - maximum density, dimensional standards, and other requirements - shall not exceed 25% of the existing requirements, and shall be recommended when one or more of the Planned Development design and developmental objectives are met. RECOMMENDATION Staff supports the variety of lot sizes, design and open space configuration of this development. The proposed residential use is likely the highest and best use of the property given the infill nature of the parcel and its adjacency to 1-84. We do feel a re-configuration of the open space in Lot 6, Block 3 would provide an added benefit to the development. We also have a concern AZ-02-007, pp -02-008, CUP02-010 Marlin Sub. AZ. PP.CUP Planning & Zoning Commission/Mayor & City Council April30, 2002 Page 15 about the design of the 1-84 buffer and how the Linder Road buffer will be accommodated given the overpass right-of-way required. There are four (4) outstanding issues which we feel may warrant a re-submission of the Preliminary Plat prior to the P&Z Commission approval. The primary outstanding issues are: Preliminary Plat 1. Item #5 - design of the 1-84 landscape buffer and fencing 2. Item #11 - design of the Linder Road landscape buffer south of Verbena Drive CUP/PD 3. Item #3 - design and configuration of Lot 6, Block 3 to provide greater visibility of the open space 4. Item #5 - provision of a second amenity If the Commission feels adequate resolution can be met with the Applicant on these issues at the hearing, Staff could support moving the applications forward at the May 2 hearing. Assuming agreement can be reached on these matters, Staff recommends approval of the Annexation and Zoning, CUP/PD and Preliminary Plat applications with the conditions noted above. AZ-024~/, PP-O241~, C~I0 Maim Sub. AZ. PP.C UP ¢".,-,' CENTRAL DISTRICT HEALTH DEPARTMENT ~ DEPARTMENT - Environmental Health Division RECEIVE Rezone # ConditiOnal Use # Preliminary / Final / Short Plat APR 1 200? Cit~ of Meridia~ City Clerk Offlr~ Return to: I~ Boise CI Eagle I~ Garden City ~[~Meridian I~ Kuna [~ ACZ CI Star I~1. CI2. [~3. I--I 4. 1~5. 1~12. 1~13. We have No Objections to this Proposal. We recommend Denial of this Proposal. Specific knowledge as to the exact type of use must be pro,~ ;~b~fore we can comment on this Proposal. We will require more data concerning soil conditions on this Proposal before we can comment. Before we can comment concerning individual sewage disposal, we will require more data concerning the depth of: CI high seasonal ground water I~ waste flow characteristics Q or bedrock from original grade Q other This office will require a study to assess the impact of nutrients and pathogens to receiving ground waters and/or surface waters. This project shall be reviewed by the Idaho Department of Water Resources concerning well construction and water availability. After written., approval from appropriate entities are submitted, we can approve this proposal for: ~;entral sewage Q community sewage systemCI community water well Q interim sewage ~[.central water Q individual sewage [3 individual water The following plan(s) must be submitted to and approved by the Idaho Department of Health & Welfare, Division of Environmental Quality: J~..eentral sewage ~ community sewage system O community water O sewage dry lines~-.eentral water ~ - Run-off is not to create a mosquito breeding problem, This Department would recommend deferral until high seasonal ground water can be determined if other considerations indicate approval. If restroom facilities areto beinstalled, then a sewage syStem~T beinstalled to meet Idaho State Sewage Regulations. We will require plans be submitted for a plan review for any: O food establishment {3 swimming pooisors~ O beverage establishment 13 grocery store E3 child care center Reviewed By: Date: ,? I~/~ ReView Sheet '-~ENTRAL DISTRICT l [^Lll DEPARTMENT MAIN OFFICE , 707 N. ARMSTRONG PL. , BOISE, ID 83704~825 0 (208) 375-5211 , FAX 327-8500 To prevent and treat disease atut disability; to protnote healthy lifestyles; and to protect attd protnote the health and quality of our environment. STORM WATER MANAGEMENT RECOMMENDATIONS It is recommended that storm water be pre-treated through a grassy swale prior to discharge to the subsurface to prevent impact to ground water and surface water quality.. The engineers and architects involved with the design of this project should obtain current best management practices for storm water disposal and design a storm water management system that is preventing groundwater and surface water degradation. Manuals that could be used for guidance are: State of Idaho Catalog of Stormwater Best Management Practices For Idaho Cities and Counties. Prepared bY the Idaho Division of Environmental Quality, July 1997. Stormwater Best Management Practices Guidebook. Prepared by City of Boise Public Works Department, May 2000. Ada / Boise County Office 707 N. Armsrong PI. Boise, ID 83704 Enviro. Health: 327-7499 Family Planning: 327-7400 Immunizations: 327-7450 Senior Nutrition: 327-7460 WIC: 327-7488 FAX: 327-8500 Serving Valley, Elmore, Boise, and Ada Counties Ada*WlC Satellite Office Elmore County Office 1606 Robert St. 520 E. 8th Street N. Boise. ID 83705 Mountain Home, ID 83647 Ph. 334-3355 Enviro. Health: 587-9225 FAX: 334-3355 Family Health: 587-4407 WIC: 587-4409 FAX: 587-3521 Valley County Office 703 N. 1st Street P.O. Box 1448 McCall, ID. 83638 Ph. 634-7194 FAX: 634-2174 MAYOR Robert D. Conic CITY COUNCIL MEMBERS William L. M. Nat,/ Keith Bird Tammy deWeerd Chefie McCandless HUB OF TREASURE VALLEY A Good Place to Live CITY OF MERIDIAN 33 EAST IDAHO MERIDIAN, IDAHO 83642 (208) 8884433 · Fax (208) 8874813 City Clerk Office Fax (208) 8884218 LEGAL DEPARTMENT (208) 288-2499 · Fax 288-2501 PUBLIC WORKS (208) 898-5500 * Fax 887-1297 BUILDING DEPARTMENT (208) 887-2211 * Fax 887-1297 PLANNING AND ZONING (208) 884-5533 · Fax 888-6854 TRANSMITTALS TO AGENCIES FOR COMMENTS ON DEVELOPMENT PROJECTS WITH THE CITY OF MERIDIAN To insure that your comments and recommendations will be considered by the Meridian Planning and Zoning Commission, please submit'your comments and recommendations to Meddian City Clerk's Office Attn: Will Berg, City Clerk, by: Transmittal Date: File No.: Request: April 25, 2002 By: Location of Property or Project: March 25, 2002 Headng Date: May 2, 2002 CUP 02-010 Conditional Use Permit for a Planned Development for single-family residential lots in a proposed R-4 zone for proposed Marlin Subdivision Winston Moore north of 1-84 and east of South Linder Road David Zaremba, P/Z (No VAR, VAC, FP) Jerry Centers, P/Z (No VAR, VAC, FP) Leslie Mathes, P/Z (No VAR, VAC, FP) Keven Shreeve, P/Z (No VAR, VAC, FP) Keith Borup, P/Z (No VAR, VAC, FP) Robert Corfie, Mayor Bill Nary, C/C Tammy deWeerd, C/C Keith Bird, C/C Cherie McCandless, C/C Water Department Sewer Department Sanitary Service (No VAR, VAC, FP) Building Department Fire Department Police Department City Attomey City Engineer City Planner Parks Department Your Concise Remarks: /-., ',,e./,..,.- Meridian School District (No FP) Meridian Post Office (FP/PP only) Ada County Highway District Community Planning Assoc. Central District Health Nampa Meridian Irdg. District Settlers Irrigation Distdct Idaho PowerCo. (FP/PPonly) U.S. West (FP/PP only) Intermountain Gas (FP/PP only) Bureau of Reclamation (FP/PPonly) Idaho Transportation Department (No FP) Ada County (Annexation on/y) '7-,0c /;Z " ~ n.,~,.,'~ RECEIVED APR. 2002 City of Meridlsn City Clerk Office Joseph Silva Deputy Chief Meridian Fire Department 540 E. Franklin Rd. Meridian, Id 83642 (208) 888-1234 Meridian Fire Department April 5, 2002 TO: FROM: SUBJECT: Meridian Planning & Zoning Commission~ Joseph Silva, Deputy Chief, Fire Prevention/ Marlin Subdivision File # CLIP 02-010 RECEIVED APR 0 9 2OO2 City Of Meridian City Clerk Offic~ :The following will be the requirements and/or concerns to provide minimum levels of fire protection for the prOpOSed project: 1. One and two family dwellings will require a fire-flow of 1,000 gallons per minute available for a duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. ~9:97 :UFC Appendix m-A Operational fire hydrants and temporary or permanent street signs combustible construction begins. UFC 901.4.2 & 901.3 3. Acceptance of the water supply for fire protection will be by the Meridian are required before Water Department. 4. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. 5. All radii shall be 28' inside and 48' outside radius for all internal roads and entrances. 6. Insure that all yet undeveloped parcels are maintained free of combustible vegetation per section 1103.2.4 of the Uniform Fire Code. 7. The roadways shall be built to Ada County Highway Standards with a minimum street width of 37'. UFC 902.2.1 8. The proposed 152 lot subdivision with an estimated 2.9 residents per household would have a total estimated population of 440 residents at build out. According to a report completed by Fire & Emergency Services Consulting Group in February of 2000 our requests for service are projected to reach 2800 in the year 2005 and 3800 by the year 2010, this is up from 2069 responses in the year 2000. April 5, 2002 Page 2 9. The proposed project lies outside the five-minute response zone goal. Achievement of this goal is subject to budgetary constraints and is intended to enhance the probability of a favorable outcome on a request for Basic Life Support. The budget constraints are typically defined as capital outlay for facilities that are located within 1.5 miles from a given location and sufficient operational funds to staffthe facilities. 10. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have a tam around. 11. The Meridian would support the strict application of the Uniform Building Co& for si&yard setbacks with no variances. This would limit the potential fire spread from building to building in those blocks. 12. Provide a fire hydrant on the extreme South end of South Linder Rd. adjacent to the common fence with 1-84. The project engineer contact the fire marshal to work out the details of this installation. 13. That a fire-flow consistent with Appendix III-A of the Uniform Fire Code be provided for the portions of the project which are not one or two family dwellings. Fire hydrants shall be placed an average of 400' apart. 1997 UFC Appendix III-A Meridian Memo From: Date: CC: Planning & Zoning Commission Torn Kuntz May 01, 2002 City Clerk 8, Planning & Zoning Staff RECEIVED MAY - 1 2002 CiTY OF MERIDIAN CITY CLERK OFFICE RE: AZ 02-007. Annexation and Zoning for Proposed Marlin Subdivision PP 02-008. Preliminary Plat Approval for Proposed Marlin Subdivision CUP 02-010 - Conditional Use Permit for Proposed Marlin Subdivision The Parks and Recreation staff has received and reviewed the above-proposed projects and have no recommendations to add at this time. · Page 1 PUBLIC HEARING SIGN-UP SHEET DATE 2-May-02 PROJECT NUMBER CUP 02-010 PROJECT NAME Marlin Subdivision NAME FOR AGAINST HAY - 2 2o02 t. zrJn�e 14: 52 2088885052 SANITARY VICE MAYOR Robot D Comic HUB OF 7'REASUREVALLE PAGE 04 CITY COUNCIL ME,vf.9ERs .,.� A Good Place to Live ... v �� O� r� LEGAL 0Ep\R�(EN.T (203) ?SS-:.99 •Fat "illiarn L, M. Nary 1 T e •'��;wl +� �►N ?33•:SDI Keith Bird T��Y dcWeerd 33 EAST IDAHO hIERIDIAN, IDAHO 83642 PUBLIC WORtiS (208) 898-5500 •Fax Cherie NICCartd)ess (208) 838•aa33 . ( Fax 208� 887-4313 City Clerk BUILDING DEPAR•�EN.j. (208) S87-2211 • Fax 887.1297 Office Fax (208) 898-4213 Pi�,W7VING �\p Zn:\'1\C (208) 834-5553 • Far TRANSMITTALS TO AGENCIES FOR COMMENTS ON DEVELOPMENT P WITH THE CITY OF MERIDIAN PROJECTS To insure that your comments and and Zoning Commisrecommendations will be considered by the Meridian Planning slon, pleasasgubmit your comments and recommendations to Meridian cityCI Attn: Will Ber C enc`s Office 9, rty Clerk, by: Transmittal Date: March 24 File No.: CUP 02-60 Request: Conditional -Use F residential lots irr By: Winston Moore Location of Property or Project: 25, 2002 r,eanng Date: May 2, 2002 for a Planned Devel )osed R-4 zone for r lent for single-fam— t—'ly osed Marlin Subdivision ►xorth of 1-84 and east of South Linder Road David Zaremba, P/Z , (IV6,,VAR VAC, FP) _-.� der y Centers, PIZ (No VAN. * AC. Fp) -----.Meridian School District (No FP) Leslie Mathes, P/Z' fNo v . VAC, Fp) -- ,q Keven Shreeve, P/Z __ AR. _,�_____, (No'; Meridian Post Once (Fp/pp pn(y) Ada County Highway District ________ P , Keith Boru V'A VAC, Fp) P/Z (No VAF7vAC, FP) Community Planning Assoc: Robert Come, Mayor �, Central District Health Bill Nary, C/C _Tammy deWeerd, C/C Nampa Meridian Irrig, Oistrict _Settlers Irrigation District Keith Bird, C/C ------- _____ Cherie McCandles$, C/C "-------_.____, Idaho Power Co. (Fpppo„jy) D-S West (FP/PP only) ------. _ Water Department ------ -_____i Sewer Department Intermountain Gas (FP/PP only) Bureau of Reclamation _Sanitary Service (No V•4R.;.VAc. Fp) --�^ Q (Fprnp „ry) Idaho Transportation Deparlment Building Department Dour Concise Remarks (No Fp,, Ada County (Annexation only) •______� Fire Department _ 7R� __ Police Department City Attorney ✓. �. City Engineer ------ � City Planner Parks Department RECEIVED APR 0 9 2002 City Of Meridian City Clerk Office APR 08 '02 15:53 2088685052 HUB OF TREASURE VALLEY I MAYOR Robert D. Come CITY COUNCIL MEMBERS William L. M. Nary Keith Bird Tammy deWeerd Cherie McCandless A Good Place to Live CITY OF MERIDIAN 33 EAST IDAHO )MERIDIAN, IDAHO 83642 (208) 888-4433 - Fax (208) 887-4813 City Clerk Office Fax (208) 888-4218 LEGAL DEPARTMENT (208) 288-2499 - Fax 288-2501 PUBLIC WORKS (208) 898-5500 - Fax 887-1297 BUILDING DEPARTMENT (208) 887-2211 - Fax 887.1297 PLANNING AND ZONING (208) 884-5533 - Fax 888-6854 TRANSMITTALS TO AGENCIES FOR COMMENTS ON DEVELOPMENT PROJECTS WITH THE CITY OF MERIDIAN To insure that your comments and recommendations will be considered by the Meridian Planning and Zoning Commission, please submit your comments and recommendations to Meridian City Clerk's Office Attn: Will Berg, City Clerk, by: April 25, 2002 Transmittal Date: March 25, 2002 Hearing Date: May 2, 2002 File No.: CUP 02-010 Request: Conditional Use Permit for a Planned Development for single-family residential lots in a proposed R4 zone for proposed Marlin Subdivision BY Winston Moore Location of Property or Project: north of 1-84 and east of South Linder Road David Zaremba, P/Z (No VAR, VAC, FP) Jerry Centers, P/Z (No VAR, VAC, FP) Leslie Mathes, P/Z (No VAR, VAC, FP) Keven Shreeve, P/Z (No VAR, VAC, FP) Keith Borup, P/Z (No VAR, VAC, FP) Robert Corrie, Mayor Bill Nary, C/C Tammy deWeerd, C/C Keith Bird, C/C Cherie McCandless, C/C Water Department L Sewer Department Sanitary Service (No VAR, VAC, FP) B' Meridian School District (No FP) Meridian Post Office (FP/PPonly) Ada County Highway District Community Planning Assoc. Central District Health -Nampa Meridian Irrig. District Settlers Irrigation District Idaho Power Co. (FP/PP only) U.S. West (FP/PPonly) Intermountain Gas (FP/PP only) Bureau of Reclamation (FP/PP only) Idaho Transportation Department (No FP) ullding Department Your Concise Rem- k Ada County (Anne)(afinn nnh. Fire Department Police Department City Attorney -City Engineer City Planner Parks Department r s. RECERTED MAR 2 9 2002 City of Meridian City Clerk Offiee