Loading...
HomeMy WebLinkAbout05-1160 City Code 2005 National Electric Code CITY OF MERIDIAN ORDINANCE NO. ¿J!i -11.60 BY THE CITY COUNCIL: BIRD, DONNELL, ROUNTREE, WARDLE AN ORDINANCE AMENDING TITLE 10, CHAPTER 1, OF THE MERIDIAN CITY CODE REGARDING THE ELECTRICAL CODE; PROVIDING A SAVINGS CLAUSE; AND PROVIDING FOR A SUMMARY; AND PROVIDING FOR A WAIVER OF THE READING RULES; AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE MAYOR AND CITY COUNCIL OF THE CITY OF MERIDIAN, IDAHO: Section 1. That Title 10, ofthe Meridian City Code is amended to read as follows: CHAPTER 3 ELECTRICAL CODE 10-3-1: NATIONAL ELECTRICAL CODE ADOYfED; ADDITIONS: The nNational eElectrical eCode of20W:2, with exception of aArticle 80; this ftArticle is informative unless specifically adopted by the local jurisdiction adopting the ÐNational eElectrical erode. Said nNational eElectrical erode of20w,2, on file in the eCity eClerk's office, and the same is hereby adopted and incorporated in full as if set forth at length herein, including additions, which additions, if in contlict with the nNational eElectrical €Code, shall overrule said a.Code. From the date in which this chapter takes effect, the provisions thereof shall be controlling within the limits of the eCity (ftArticle 80 to the nNational eElectrical Geode is not adopted). A. Buildings Moved From One Location To Another: When a building is moved fÌ"om one location to another the Service Entrance shall be inspected and made to conform to the requirements of the current edition of the National Electrical Code. B. Unfinished Studded Partitions: On November 2, 1963, the State Electrical Board ruled that when unfinished studded partitions are in place in residential basements, indicating that the enclosed areas are intended for rooms, such enclosed areas shall be considered as rooms. The wiring, including receptacle outlets as required by Article 210-52 of the National Electrical Code shall be installed before the wiring of the building is approved. C. Supporting Partitions: When a residential basement is not divided into separate rooms and only an unfinished supporting partition is in place, at least two (2) outlets shall be installed in such supporting partition, facing the area on opposite sides of the partition. ELECTRICAL CODE AMENDMENT - 2005 Page 1 of? D. Utility And Storage Spaces: The requirement that receptacle outlets be installed within six feet (6') fÌ"om any wall space in dwelling type occupancies Article 210-52 National Electrical Code does not apply to hallways, bathrooms, utility rooms, laundry rooms, furnace rooms and storage spaces. The number of outlets in these areas is optional, but adequate branch circuit capacity must be provided for lighting and for all electrical equipment to be installed in such areas without the use of extension cords. E. Separation Of Buildings By Fire Walls: 1. In general, the National Electrical Code permits only one service to a building Article 230-2 and 230w21. 2. Article 100 of the National Electrical Code defines "Building" as "A structure which stands alone or which is cut off from adjoining structures by fire walls with all openings therein protected by approved fire doors". F.F or the purpose of determining the number of services which may be run to -a-building or structure, a fire wall shall be a masonry wall, not less than four inches (1") thick, which extends from the foundation to the roof sheathing. (Bulletin No- 52 issued-JUfle 1, 1966.) G. Aluminum Conduit For Mast Type Services Prohibited: When the service conduit is used as a mast to support the service drop, rigid steel conduit, or intermediate metal conduit (!MC), shall be used. Aluminum conduit will not be approved for this purpose unless approved braces are provided to relieve the conduit of horizontal strain. Guy wires will not be approved for this purpose. H. Approval Of Certain Voltage Installations: Due to the many misunderstandings and misinterpretations of the National Electrical Code requirements for conductors and service disconnects, etc., on installations of over six hundred (600) volts, it has become necessary to require that all installations of voltages over six hundred (600) volts that are customer .owned or operated must be submitted for prior plan approval to the Electrical Board representative in the area in which the installation is to be made. I. Street Lighting Waiver, Photo.Electric Cell Required: In the event street lighting requirements are waived in the case of an R-4 single-family dwelling development or subdivision, the developer and lot owner shall be responsible for ensuring that there is a yard light installed in the ftont yard of each house in said development; that the yard light shall be controlled by a photo-electric cell which causes the yard light to come on and shut off automatically and said yard light shall be electrically wired directly to the residence's electrical breaker panel and comply with the National Electrical Code. (Gffi.03 1021,5 20 2003) ELECTRICAL CODE AMENDMENT - 2005 Page 2 of? 10-3-2: STATE LICENSE REQUIRED: It shall be unlawful for any person, firm or corporation to cany on the business of electrical wiring without first having secured a s~tate eContractor's lLicense or have in his possession a lLicense recognized by the s~tate e~lectrical \}Bureau. (Ord. 03 1024,---S- 20 2003) 10-3-3: INSTALLATIONS BY OWNER OF BUILDING: If an oWner wishes to do wiring in his own building, he may do so without a 5~tate eContractor's !License, but he must first obtain a permit as required by section 10-3-4 of this chapter. The sCity eElectrical ilnspector may refuse to issue a permit to such person, if, in his estimation, such person is not competent to install the electrical work to be done under said permit applied for in accordance with the regulations ofthis chapter. (Ord. 03 1024, 5 20 2003) 10-3-4: PERMIT REQUIRED; APPLICATION; ISSUANCE: It shall be unlawful for any person, firm or corporation to place or install in any building any wiring, apparatus or fixture for the use of electric current for light, heat or power, or to make any alterations or changes in, or additions to any wiring, apparatus or fixtures for such use, without first obtaining trom the eCity eElectrical ilnspector a written permit to do such work. Such permit shall state the kind of work to be done and the amount, and shall cover only work SO specified. The contractor, person, firm or corporation shall submit a plan of the wiring system to be followed, if deemed necessary by the eElectrical ilnspector. Said permit shall also state the location by street and number of the building where such work is to be done, and shall be valid only for the location stated. Provided, however, that this section shall not be construed as requiring a permit for ordinary repairs to the old installations where the cost value of such repairs, including material and labor, does not exceed fifty dollars ($50.00), but in all cases, the e~lectrical iinspector must be notified immediately upon the completion of such work for his inspection and approval. Fees for permits and inspections shall be fixed by the eCity eCouncil. (Ord, 03 1024, 5 20 2003) 10-3-5: INSPECTION REQUIREMENTS: A. Notice For Inspection; Tag By Inspector: It shall be the duty of the eCity eElectrical ilnspector, or the 5~tate iinspector, if the eCity so chooses, to inspect or cause to be inspected any and all work for which permits have been issued within forty eight (48) hours (weekends and holidays excluded) after time of notice, in writing, by the said person doing the said work, that same is ready for inspection, which will not be considered ready for inspection and covering until all enclosed plumbing, steam heating, furnace work and gas fittings are also in place. Inspection shall, when necessary, be made two (2) or three (3) times during the progress of the installation; fIrst when said work is roughed in, and last, when work is completed; and it shall be the duty of the sCity eElectrical ilnspector or person qualified and delegated by him ELECTRICAL CODE AMENDMENT - 2005 Page 3 of? as his qualified representative to indicate inspection of any work by a tag or label which state the date and whether rough in or final inspection has been made, and it shall be unlawful for any workman or other person to lath or otherwise conceal any electrical wiring until such rough in inspection tag has been placed. B. Issuance Of Certificate Of Inspection: 1. Upon application for inspection of any wiring apparatus, or appliances as hereinafter provided, the eCity eElectrical tInspector shall, after inspection and examination, issue a certificate showing the results of such examinations and require to be made the necessary corrections. C. Disconnect Defective Electrical Wiring, Fixtures: 1. If the said eCity eElectrical ¡Inspector shall find any part of any electric wiring, apparatus or fixtures in or on any building in the eCity to have been installed without a permit or not in accordance with the provisions of this chapter, or to be dangerous to life or property, the eCity eElectrical ilnspector shall have the right and power and it is hereby made his duty to disconnect such defective wiring and place a seal upon it. He shall at the same time give written notice of such disconnection to the owner or occupant of the building. 2. After such disconnected wiring, apparatus, or fixtures have been put in the condition required by this chapter, the seal or seals so placed shall be removed by said eElectrical ¡Inspector. It shall be unlawful for any person to use any current, through, or by means of such disconnected wiring, apparatus or fixtures or to attach other wires for the supply of current to such disconnected wiring, apparatus or fixtures or to remove, break or deface any seal so placed. D. Right Of Entry: The eCity eElectrical ilnspector shall have the right to enter any premises at all reasonable hours for the purpose of inspecting the same. E. Inspection Fees: Before any inspection is undertaken, the applicant shall pay to the eCity aBuilding èDepartment an inspection fee as established by the eCity eElectrical ilnspector and approved by the eCity eCouncil by resolution, which inspection fee, or schedule thereof, shall be available at the eCity eClerk's and aBuilding èDepartment's eOffice during regular business hours. (Ord. 03 1024, 5 20 2003) 10~3~6: INSTALLATION OF METERS AND OUTSIDE WIRING: A. Accessibility; Prohibited Locations: Meters must be placed in a location ftee ftom vibration and accessible to the meter readers, testers and inspectors at all times. Under no circumstances will meters be installed in bathrooms, bedrooms, clothes closets, over doors, in stairways, attics or places likely to cause the visits to the meters to be an annoyance to the occupants. ELECTRICAL CODE AMENDMENT - 2005 Page 4 of? B. Meters And Service Equipment: Meters must be installed on the outside of buildings at a height of not less than four and one~half feet (4 1/2') or not more than six feet (6') from the ground. In office buildings, apartment buildings, and commercial buildings of multiple occupancy, meters may be mounted inside, providing a readily accessible place is provided for meters and service equipment. Said meters and service equipment shall be kept free and clear of all obstructions. (Ord. 03-1024, 5-20-2003) 10-3-7: SPECIFICATIONS OF CIRCUIT WIRING: All buildings hereinafter erected to be used for ~ commercial purposes ~h as, but not limited to, churches, stores, halls, S0Hool buildings, commercial garages, manufacturing establishments, auto camps, and gas service stations ffi1:ffit shall be wired in conduit, or permissible mctalJic covered wire metal raceway, with the exception of communication and signaling. A) Suspended ceilings luminaire are to be supported by independent support wires trom structure to fixture, including wiring boxes for smaller luminaries such as exit signs. Luminaires over one foot square foot shall have two support wires, one on each diagonal comer. Bell ringing transformers shall be accessible and not located in attics. Residential smoke detectors shall be wired to a general wiring circuit, not a dedicated circuit. B) C) The City of Meridian further adopts Title L Chapter 10 '~Rules Governing Certification ~lDd Approval of Electrical Products and Materials."ofthe State ofIdaho, including but not limited to, the right of the City to require independent certification of circuit wiring for approval. All provisions herein are effective on final passage and approval and not retroactive. (Ord.03 1024,5 20 2003) 10-3-8: NONLIABILITY OF CITY: This chapter shall not be construed to relieve from, or lessen the responsibility of, any person owning, operating or installing any electrical wires, appliances, apparatus, construction or equipment for damages to anyone injured or damaged either in person or property by any defect therein; nor shall the eCity or any agent thereof be held as assuming such liability by reason of inspection authorized herein or certificate of inspection issued by the €City eElectricalilnspector. (Ord. 03 1021, 5 20 2003) 10-J.9: VALIDITY: Should any section, paragraph, sentence, clause or phrase of this chapter or of the code hereby adopted be declared unconstitutional or invalid for any reason or cause, the remainder of said chapter or code shall not be affected thereby and the same shall not invalidate or void the remainder of this chapter or said code. (Ord. 03-1024, 5-20-2003) ELECTRICAL CODE AMENDMENT - 2005 Page 5 of 7 10-3-10: PENALTY: Any person violating the provisions of this chapter shall be deemed guilty of a misdemeanor. (Ord. 03-1024, 5-20-2003) 10-3-11: SEVERABILITY: The provisions of this chapter shall be deemed severable and a finding by a court of law that a provision of this chapter is unlawful shall have no effect on the remaining provisions. (Ord. 03-1024, 5-20-2003) 10-3-12: REPEALER: All ordinances, resolutions, orders or parts thereof in cantlict herewith are hereby repealed, rescinded and annulled. (Ord. 03-1024, 5-20-2003) 10-3..13: SAVING CLAUSE: This chapter does not affect an action or proceeding commenced or right accrued before this chapter takes effect. (Ord. 03-1024, 5-20-2003) 10-3-14: DATE OF EFFECT: This chapter shall be in full force and effect on August 1,2003. (Ord. 03 1021, 5 20 2003) after its passage. approval and publication on or about August 1.2005. Section 2. That pursuant to the afflTmative vote of one-half (112) plus one (1) of the Members of the full Council, the rule requiring two (2) separate readings by title and one (1) reading in full be, and the same is hereby, dispensed with, and accordingly, This ordinance shall be in full force and effect after its passage, approval and publication on or about August 1, 2005. -#> rr: PASSED by the City Council of the City of Meridian, Idaho, this 2 e, day of c/ ~ , 2005. ~ J¿ APPROVED by die Mayor of die City of MeridiaD, Idaho, tbis 2 f!, -day of ~ , 2005. APPROVED: 111111111""1 ,,\ \",-.1 Of II" <, A." -;::::'-.(\0.' - Page 6 of 7 NOTICE AND PUBLISHED SUMMARY OF ORDINANCE PURSUANT TO LC. § 50-901(A) CITY OF MERIDIAN ORDINANCE NO. 05~ 1/60 PROVIDING FOR AN AMENDMENT MERIDIAN CITY ELECTRICAL CODE ORDINANCE An Ordinance of the City of Meridian amending Title 6, Chapter 2, of the Meridian City Code regarding the Building Code and the adoption of the International Building Code with some exceptions. A full text oftms ordinance is available for review at Meridian City Hall, City of Meridian, 33 East Idaho Avenue, Meridian, Idaho. This ordinance shall be in full force and effect after its passage, approval and p~\:di(\altltjn~ or about August 1,2005. \\ ......c;: ~j¡r-~/¡I ,,\\ ~ VI~' . II~., ,,"-~ ...~ ~ - ! v l"':-efW0R.4 ~ '% ( :: ~ Ö ~- City ofMeri~ian. = SEAL ~. Mayor and CIty Council ;" ~ By: William G. Berg, Jr., City Cler~ "741. '~.D j ~ "ð -,~r 181 . ..¡: ~ "'f ~' First Reading: 6- 2,,8-t'?" "'~'ll Cbum'f . ,\,'è~'~ Adopted after first reading by suspension ~r the, RlJoI\Nts' ~llowed pursuant to Idaho Code 50-902: YES X NO Second Reading: Third Reading: STATEMENT OF MERIDIAN CITY ATTORNEY AS TO ADEQUACY OF SUMMARY OF ORDINANCE NO. 05- 1/60 The undersigned, William LM. Nary, City Attorney of the City of Meridian, Idaho, hereby certifies that he is the legal advisor of the City and has reviewed a copy of the attached Ordinance No. 05- 1/ b /J of the City of Meridian, Idaho, and has found the same to be true and complete and provides adequate notice to the public pursuant to Idaho Code § 50-901A (3). DArnDthis2ß~d~of ~ 2005 William. LM. ary City Attorney ELECTRICAL CODE AMENDMENT - 2005 Page 7 of 7