Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CC - Revised Landscape Plan
10 cc c c LANDSCAPE NOTES: cc U co a 1. REGULATIONS & STANDARDS topsoil or improving onsite topsoil per the approval of the 7.2. All remote control valves (including master control valve)to NOTE: BACKFILL SHALL BE 100%TOPSOIL. cc J 1.1. All contractor work shall be conducted in accordance with Landscape Architect. have flow control device. NOTES: REMOVE ALL TAGS,TWINE OR WATER SETTLE ALL PLANTINGS TO ISPWC (Idaho Standard Public Works Construction)2017 (or 3.2.5. All lawn areas shall receive 12" minimum depth of topsoil. 7.3. Install indoor rated controller. Coordinate with general 1. DO NOT DAMAGE OR CUT LEADER OTHER NON BIODEGRADABLE ENSURE PLANT ROOTBALL most recent published); and City of MERIDIAN, ID codes, 3.2.6. All planter areas shall receive 18" minimum depth of topsoil. contractor on exact location. 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. MATERIALS ATTACHED TO PLANT OR MAINTAINS Z' HEIGHT ABOVE (� 5� (� = standards and state and local regulations. 3.3. If imported topsoil is used it must be from a local source and 7.4. Controller to include On/Off rain switch or other rain shut off 3. TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED ROOT MASS. EXISTING SOILS WHEN COMPLETE. v u V nO Vn v 0 2. EXISTING CONDITIONS be screened free of any debris or foreign matter. Topsoil must device that does not alter program. FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT (a Q 0 p 00 2.1. All utilities shall be located prior to construction and protected. not contain rocks, sticks, lumps, or toxic matter. 7.5. Irrigation system piping to be minimum class 200 PVC or CONTRACTOR'S EXPENSE. 7- Any damage to structures, utilities or concrete will be replaced 3.4. Smooth, compact, and fine grade topsoil in lawn areas to approved equal, sleeves to be double the size of pipes 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. LANDSCAPE c 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP OF THE ROOTBALL. ARCHITECTURE at contractor's expense. smooth and uniform grade .5" below adjacent surfaces. located within, all wires to be contained in separate sleeves 3 E 2.2. The site has many existing improvements such as 3.5. Amend soil for all new plantings 2 parts topsoil & 1 part 1-1/2"dia min. 6. 5' DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3"OF MULCH MIN. DO & MASTER PLANNING o underground utilities, curb and gutter, light poles and compost. 7.6. Use common trenching where possible. NOT PLACE MULCH WITHIN 2"OF TRUNK OF TREE. a sidewalks. 4. LAWN AREAS 7.7. All PVC located under hardscapes to be schedule 40 PVC (208) 345-0500 .0 2.3. See Engineer's plans for information about existing features. 4.1. All lawn areas shall be sodded regionally grown tall-turf type with same req's as above. 404(2 S 8 -0t. 00 154 = 3. GRADING &SITE PREPARATION fescue or approved other by owner. 7.8. All mainline pipe and wires to be buried a minimum of 18"and Boise ID 83702 U "Prepare finish grades for planting by grubbing and removing 4.2. Lay sod within 24 hrs of harvesting and form a solid mass with all lateral piping to be buried a minimum of 12" below grade. StackRockGroup.com ' weeds. If necessary apply Round-Up (or equivalent herbicide), offset, tightly fitted joints on even grades. 7.9. All wires to be 14 gauge direct bury wire at a minimum. Size MULCH 2" MIN. using a certified applicator. Remove rocks and other materials 5. PLANTS wire for correct voltage loss. TOP TWO STRUCTURAL - AWAY FROM TRUNK M WILLET C HOWARD, PLA 0 over 2". 5.8. All plant material shall be installed per industry standards. 7.10. Supply a minimum of(2)spare wires to furthest valves from ROOTS: <3" BELOW TOP GRAFT VISIBLE ABOVE SOIL OF PLANT. OFFICE: 208 345.0500 EMAIL: a FOLD BURLAP FROM TOP ( ) y 3.2. All gravel overprep to be removed and disposed of off site. 5.5. All plant material shall meet or exceed the minimum federal controller in all directions. OF ROOTBALL. LINE WILL@STACKROCKGROUP.COM �;, OF ROOT BALL DOWN 3" DEEP MULCH MIN. 0 3.3. Finish grade to be smooth transition to allow for entire site to standards as regulated by ANSI z60.1, American Standard for 7.11. Sprinkler heads shall have a matched precipitation within INTO GROUND; SET TOP www.STACKROCKGROUP.COM be a natural flowing space. Nursery Stock. Plants not meeting these standards for quality, each control circuit.Velocities shall not exceed 5 feet per LOWEST STRUCTURAL SOIL LINE OF THE TOP OF OF BALL FLUSH WITH " BELOW TOP OF � 3.4. Fine grade lawn areas to elevations set by Engineer's plans or plants determined to be unhealthy by Owner's second. ROOT<5 THE ROOT BALL AFTER FINISH GRADE LAWN OR PAVING with o positive drainage away from structures. representative, will be rejected. 7.12. Contractor is responsible complying with all codes and paying ROOT BALL REMOVING EXCESS SOIL. THE GRAPHICS AND DESIGNS (� � 3.5. Refer to Engineers plans for grading information &for all 5.6. All Ball and Burlap trees to be installed per Balled and all permits necessary. 212 2-3"OF MULCH ON THIS SHEET A R E N drainage pipes and locations. Protect and retain drainage at Burlapped planting detail. 7.13. Sprinkler heads shall have matched precipitation within each BACKFILL MIX SEE DELIVERABLES THAT REMAIN o all times. 5.7. All shrubs to be planted per Shrub Planting detail. control circuit. Velocities shall not exceed 5 feet per second. NOTES AND 12"TO 18" FOR AT ALL TIMES PROPERTY OF 0R 3.6. No pooling or standing water will be accepted per industry 5.8. Trees and shrubs over 36"shall not be planted within clear 8. CONTRACTOR RESPONSIBILITIES SPECIFICATIONS. LARGER SHRUB STACK ROCK GROUP, INC. 7- standards. vision triangles per city code. 8.1. Estimated quantities are shown for general reference only. ROOT BALLS, 0 3. SOILS 5.9. Fertilize all trees and shrubs with 'Agriform' planting tablets or Contractor shall be responsible for all quantity estimates. MAKE DEPTH MIN. REPRODUCTION OR REUSE OF CN 3.2. Reuse of existingtopsoil that has been stockpiled on site is approved equal.Apply per manufacturers recommendations. 8.2. All plant material and workmanship shall be guaranteed for a SOIL SAUCER>3" HIGH 4" DEEPER THAN p p pp q pp y p p p g REMOVE AT END OF THIS PRODUCT CONTAINED 0 permitted if: 6. PLANTER BED MULCH period of one year beginning at the date of Acceptance by PROJECT BALL) HERE IN IS PROHIBITED 3.2.1. Topsoil is tested and analyzed to ensure a proper growing 6.1. All planter beds to receive 3"depth of black&tan mini rock Owner. Replace all dead or unhealthy plant material BALL AND BURLAP PLANT(IF WITHOUT THE WRITTEN o medium. Provide additional amendments as determined mulch or approved equal, submit for approval prior to immediately with same type and size at no cost to Owner. _ CONTAINER-GROWN PLANT CONSENT OF STACK ROCK CD by soil tests.And placement. Install over commercial grade weed barrier 8.3. Landscape contractor to turn in as built drawings at the end of CUT AND FOLD WIRE 9 p 9 G R O U P I N C BASKET FROM TOP OF SOIL SURFACE WITH ROOTS LOOSENED AND 0 3.2.2. Topsoil is to be loose, friable sandy loam that is clean and fabric per manufacturer recommendations. project. Substantial completion will not be granted until 2 PULLED OUT TO PREVENT oc ROOTBALL COMPACT SOIL UNDER ROUGHENED TO free of toxic materials, noxious weeds, weed seeds, 7. IRRIGATION copies @ 1"=20' scale are turned in and approved by owner's ROOTBALL TO 90/o o PLANT FROM BECOMING ROOT ©2019 STACK U PROCTOR. BIND WITH NEW SOIL rocks, grass or other foreign materials. 7.1. Irrigation system shall be built to the following specifications: representative. BOUND) ROCK GROUP, INC. W3.2.3. Topsoil should have a ph of 6.5 to 8.0. 7.1.1. Adhere to city codes when connecting to city water. 9. In the event of a discrepancy, notify the Landscape Architect y 3.2.4. If on site topsoil does not meet these minimum standards 7.1.2. All irrigation material to be new with manufacturers'warranty immediately. a contractor is responsible for providing approved imported fully intact. w BALL & BURLAP TREE PLANTING /-� SHRUB PLANTING a6 I L Seals � lLPRELIMINARY N 3/4"= 1'-0" 3293-01 1"= 1'-0" 329333-03 CD OF LANDSCAPE REQUIREMENTS: PER CITY OF MERIDIAN IDAHO MUNICIPAL CODE ROCK MULCH OR APPROVED OTHER, TYP POINT OF BEGINNING LANDSCAPE BUFFER: *(1) 2"-CAL TREE PER 35 LF ��s� A-16830.9 0 .08.20 STREETS & PROPERTY PERIMETEROIDUU ou - - 0 . 0 lANDSCA4� �� STREET& PERIMETER TREE SPACING: 1 CLASS II TREE PER 35 LF STREET LENGTH (LF) TREES REQUIRED EXISTING TOTAL TREES PROVIDED ADJUST ALL NOT FOR CONSTRUCTION BRIGHT ANGEL AVE. 240' 7 3* 5** PERIMETER STAR DRIVE 335' 10 7 10 TREES PER * MITIGATION IS NOT REQUIRED FOR 1 EXISTING DAMAGED TREE ON BRIGHT ANGEL IRRIGATION LLI ** TOTAL STREET TREE COUNT IS REDUCED BECAUSE TREES WOULD NEED TO BE IN HOMEOWNERS FRONT YARD. TOTAL TREE COUNT IS ADDRESSED WITH PLACEMENT OF TREES AT PERIMETER LINES, TREES SHALL BE 5' c PERIMETER LENGTH (LF) TREES REQUIRED EXISTING TOTAL TREES PROVIDED S S CLEAR OF LINES, Y WEST 150 4 5 5 ° TYP U NORTH 135 4 1 4 0 J J J J d 0 COMMON AREA TREES: 1 CLASS II TREE PER 8000 SF AREA(SF) TREES REQUIRED EXISTING PROVIDED o COMMON AREA 15 1075 1 1 1 y 4. COMMON AREA 20 3227 1 1 1 y cu ADDITIONAL REQUIREMENTS: a *"TREES SHALL NOT BE PLANTED WITHIN 10' OF ACHD STORM DRAIN PIPE, STRUCTURES OR c FACILITIES", or 10'WITHIN A FIRE HYDRANT 3 *SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND _ INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM 0 y *NO TREES OR SHRUBS OVER 36" HIGH SHALL BE PLANTED WITHIN THE 40'X40' CLEAR VISION TRIANGLES AT INTERSECTIONS CV aX W W W W W W WW W W VJJ^^ d41 3 PLANT SCHEDULE v TREES BOTANICAL/COMMON NAME CONT CAL SIZE QTY REMARKS y Acer platanoides'Parkway' /Norway Maple B&B 3"Cal 6 CLASS II, 40' H X 25' W a > ° HOMEOWNERS Q a SHALL RIVE > n/ a w Liquidambar styraciflua'Worplesdon' /Worplesdon Sweet Gum B&B 2" 2 CLASS II, 40' H X 25' W S S LL 0 LANDSCAPE a TO EDGE Q ILL! 0OF LU o Picea omorika'Bruns' /Bruns Spruce B&B 10'H 13 CONIFER _ LU SIDEWALK, 30' TALL&8' WIDE TYP UTILITY NZ m EASEMENT z N Of 0 PER CIVIL IN cc (� opo`000° Pinus sylvestris'Pom Pom' /Scotch Pine B&B 3'-5' H 1 15'H x 10'W LL (n a, V7 °o 0 7 T °OOOOOOoO a Pyrus calleryana Chanticleer /Chanticleer Pear B&B 2" 7 CLASS I, 35� H X 15� W �� ��►����� ��� DRAIN W W >L ` ` • C C ° + . . - � / _L I I REVISIONS p W W MIRK DATE Description Tilia cordata 'Greenspire' /Greenspire Littleleaf Linden B&B 3"Cal 2 CLASS II, 60' H X 40' WQJ d ° � ® ** ## _ OJ Y W L a-. SHRUBS BOTANICAL/COMMON NAME CONT FIELD2 SIZE QTY REMARKS S STAROR VE — � Arctostaphylos uva-ursi 'Massachusetts' /Massachusetts Manzanita 2 gal 19 2"H X 4'+ •� O a Y Y Y Y W W W W A to W W Y Y Y Y W v Calamagrostis x acutiflora Karl Foerster /Feather Reed Grass 1 gal 20 5' H X 2.5' W d" _ Daphne x burkwoodii 'Carol Mackie' /Carol Mackie Daphne 2 gal 3 2.5H x 4'W-DROUGHT TOLERANT W W W JOB NO: 18-1058 �- W W '• DATE: 09.08.2020 0 Lavandula angustifolia'Munstead' /Munstead English Lavender 2 gal 26 1' - 1.5' H X 2' W DRAWN BY: KS o W W W W W W B W W W W W CHECKED BY: JB .J 0 W W Y Nassella tenuissima Pony Tails' /Mexican Feathergrass 1 gal 16 12"H x 24"W FST� ° DRAWING TITLE cc f0 O�Q�/� Y W .\ • W W W o Physocarpus opulifolius 'Diablo' /Diablo Ninebark 3 gal 2 8' H X 8' W LANDSCAPE W Y Y Y Y Y W W W W S PLAN Y Rhus aromatica'Gro-Low' /Gro-Low Fragrant Sumac 2 gal 8 2.5'H x 6'W+ U W W Y W Y Y � W w W (n 0 W W Viburnum x burkwoodii Anne Russell' /Burkwood Viburnum 2 gal 4 6' H X 6' W 20 40 60 feet 3:a + W a o of 2 Q0 ° d A a Yucca filamentosa'Color Guard' /Adam's Needle 1 gal 8 3'H x 3'W NORTH SCALE: 1" = 20' �Ijz °°° SHEET NUMBER U m y O Ll 00 U v Y a U t Q U 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 CU a U J 102 103 104 105 106 POINT OF 0 101 BEGINNING B 0 200 cb CGG30MG� LANDSCAPE c ARCHITECTURE 107 & MASTER PLANNING Q 0 TREE INVENTORY: o (208) 345-0500 TREE ID CAL(IN) SPECIES TREE ID CAL(IN) SPECIES 404 S 8th St.#154 83702 N 101 17" PINE 114* 4" LINDEN Boise, ID �, St ackRockGroup.oup.com 102 11" PINE 115 8" LINDEN 103 17" P WILLET C HOWARD, PLA 104 13" PINE 117 11" LINDEN OFFICE: (208)345.0500 EMAIL: WILL@STACKROCKGROUP.COM PINE 118 4.5" LINDEN 108 105* 13" A www.STACKROCKGROUP.COM N 106 15" PINE(DAMAGED) 119 8" LINDEN 107 16" PINE 120 4" GINKGO ° 108 14" PINE 121* 8" SHADE TREE a• THE GRAPHICS AND DESIGNS ON THIS SHEET ARE 00 109 5" GINKGO 122* 4" GINKGO S DELIVERABLES THAT REMAIN Lo 110* 4" GINKGO 123* 6" LINDEN • AT ALL TIMES PROPERTY OF `° 111 7" GINKGO 124* 9" LINDEN n STACK ROCK GROUP, INC. 112 2.5' LINDEN 125 9" LINDEN (DAMAGED) REPRODUCTION OR REUSE OF 113 4" LINDEN THIS PRODUCT CONTAINED 109 HERE IN IS PROHIBITED a EXISTING TREE IS LOCATED IN PROPOSED BUILT AREA AND REQUIRES MITIGATION WITHOUT THE W R I TT E N TOTAL EXISTING TREE CALIPER INCHES TO BE REPLACED: 76" 110 CONSENT OF STACK ROCK Y G R O U P I N C TOTAL CALIPER INCHES MITIGATED: 77.5" _he • ©2019 STACK NOTE: • ROCK GROUP, INC. * MITIGATION THROUGH 3" CALIPER TREES TO EXCEED MINIMUM REQUIREMENTS 111 d * ALL OTHER TRASH TREES MAY BE REMOVED WITHOUT MITIGATION e Lu Seals �6 ILL > PRELIMINARY S Q e 125 A Lu Lu OF Ih • EVERGREEN TREE MITIGATION CONVERSION �� SS�N gUso CALIPER INCHES CONIFER HEIGHT All 2„ 6' m r z 3" 8' �w 4 10 124 ��, A-16830 d 09.08.20 Sc • • LANDSCAPE REQUIREMENTS: ° a A NOT FOR CONSTRUCTION PER CITY OF MERIDIAN IDAHO MUNICIPAL CODE 123 LANDSCAPE BUFFER: 114 115 0 ILL] LANDSCAPE *(1) 2"-CAL TREE PER 35 LF 113 ° a STREETS & PROPERTY PERIMETER 116 o S c� STREET& PERIMETER TREE SPACING: 1 CLASS II TREE PER 35 LF Q O 122 STREET LENGTH (LF) TREES REQUIRED EXISTING TOTAL TREES PROVIDED 120 BRIGHT ANGEL AVE. 240' 7 3* 5** C/, STAR DRIVE 335' 10 7 10 o * MITIGATION IS NOT REQUIRED FOR 1 EXISTING DAMAGED TREE ON BRIGHT ANGEL o ** TOTAL STREET TREE COUNT IS REDUCED BECAUSE TREES WOULD NEED TO BE IN HOMEOWNERS FRONT YARD. TOTAL TREE COUNT IS ADDRESSED WITH PLACEMENT OF TREES AT PERIMETER Q- PERIMETER LENGTH (LF) TREES REQUIRED EXISTING TOTAL TREES PROVIDED 117 °J WEST 150 4 5 5 NORTH 135 4 1 4 w COMMON AREA TREES: 1 CLASS II TREE PER 8000 SIF F`STq 121 cn 1A (SF) TREES REQUIRED EXISTINGPROV1 118 ED �OF ") COMMON AREA 15 075 o COMMON AREA 20 3227 1 1 1 Q ADDITIONAL REQUIREMENTS: S J *"TREES SHALL NOT BE PLANTED WITHIN 10' OF ACHD STORM DRAIN PIPE, STRUCTURES OR J d o FACILITIES", or 10'WITHIN A FIRE HYDRANT ca *SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND 3 INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM \ Q o *NO TREES OR SHRUBS OVER 36" HIGH SHALL BE PLANTED WITHIN THE 40'X40' CLEAR VISION TRIANGLES AT INTERSECTIONS 119 T _ a e e G e • Q ooeeo w C U Lu G LL I 2 I..I.J > Q N o o � N a) NOTE: BACKFILL SHALL BE 100%TOPSOIL. NOTES: REMOVE ALL TAGS, TWINE OR WATER SETTLE ALL PLANTINGS TO 0 20 40 60 feet U) 1. DO NOT DAMAGE OR CUT LEADER OTHER NON BIODEGRADABLE ENSURE PLANT ROOTBALL a 2. DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. MATERIALS ATTACHED TO PLANT OR MAINTAINS Z" HEIGHT ABOVE c 3. TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED ROOT MASS. EXISTING SOILS WHEN COMPLETE. NORTH SCALE: 1" - 20' REVISIONS FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. MIRK DATE Description 4. WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. cu =5 5. REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP 3 OF THE ROOTBALL. ® *' *' 6. 5' DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3" OF MULCH MIN. DO NOT PLACE MULCH WITHIN 2"OF TRUNK OF TREE. a a MULCH 2" MIN. TOP TWO STRUCTURAL - AWAY FROM TRUNK m ROOTS: <3" BELOW TOP FOLD BURLAP FROM TOP / OF PLANT. \ GRAFT VISIBLE ABOVE SOIL OF ROOTBALL. LINE OF ROOT BALL DOWN 3" DEEP MULCH MIN. JOB NO: 18-1058 INTO GROUND; SET TOP DATE: 09.08.2020 LOWEST STRUCTURAL °' ROOT<5" BELOW TOP OF SOIL LINE OF THE TOP OF OF BALL FLUSH WITH DRAWN BY: KS o ROOT BALL THE ROOT BALL AFTER FINISH GRADE LAWN OR PAVING CHECKED BY: JB REMOVING EXCESS SOIL. 2y-2 2-3" OF MULCH - BACKFILL MIX SEE DRAWING TITLE I'll" c NOTES AND 12"TO 18" FOR oil C SPECIFICATIONS. LARGER SHRUB o ° ROOT BALLS, c� � SOIL SAUCER>3" HIGH MAKE DEPTH MIN. EXISTINGTREE REMOVE AT END OF 4" DEEPER THAN INVENTORY & PROJECT BALL) BALL AND BURLAP PLANT(IF MITIGATION Lu U) CUT AND FOLD WIRE CONTAINER-GROWN PLANT w a BASKET FROM TOP OF SOIL SURFACE WITH ROOTS LOOSENED AND PLAN w Q COMPACT SOIL UNDER ROUGHENED TO PULLED OUT TO PREVENT Q Q ROOTBALL ROOTBALL TO 90% PROCTOR. BIND WITH NEW SOIL PLANT FROM BECOMING ROOT BOUND) SHEET NUMBER U d cu cu BALL & BURLAP TREE PLANTING SHRUB PLANTING 2 L 101 1 3/4"= 1'-0" 3293-01 1" = 1'-0" 329333-03 0 a Y a U Q H 1 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 9 10 3 c nz cc a c. 0 U co C fC J U O O STACK ROCK co C� G30O Mp C6 LANDSCAPE N c ARCHITECTURE a E & MASTER PLANNING U O o (208) 345-0500 404 S 8th St.#154 Boise, ID 83702 0 StackRockGroup.com C� WILLET C HOWARD, PLA a OFFICE: (208)345.0500 EMAIL: U WILL@STACKROCKGROUP.COM cY) p www.STACKROCKGROUP.COM N a o (� THE GRAPHICS AND DESIGNS ON THIS SHEET ARE CIO DELIVERABLES THAT REMAIN o AT ALL TIMES PROPERTY OF C6 STACK ROCK GROUP, INC. o REPRODUCTION OR REUSE OF CV THIS PRODUCT CONTAINED HERE IN IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF STACK ROCK G R O U P I N C U O ©2019 STACK W ROCK GROUP, INC. U, C 0 J Seals �6 U- PRELIMINARY t cn n ti $0C -168309.08.20Sl.ApB,�, k5V0 - ISI 0 NOT FOR CONSTRUCTION / W W O Y W I ,L6 W I U I � / Y W I bVllO W 1 W I Lu W 1 eoeazro8 CL V L U' 40 MD. T + + + -41 ,l, W W O WiEBidm EOAES O x 70 fB �' �' • O + + + 0 o W W I w 'W ' �" �" I KITCHEN �I CHEVI HIN O E y W y W I PLANT SCHEDULE W W W W : s s° o 3 TREES BOTANICAL/COMMON NAME W W • -� \ Carpinus betulus'Franz Fontaine' /Franze Fontaine Hornbeamco W Ir — to N J QJ Q 26605H 26 SH $O°°•°O°O°°°0°•0°0°°o°°°S Pinus sylvestris 'Pom Porn' Scotch Pine R RIEfts « < If ❑❑ iii L__R Q Q° O O ATING CEIUN -- Ny Prunus x cerasifera 'Cripoizam' Crimson Pointe Flowering Plum O MA TA3A0 N3HOTWcc >m QGREAT RM o CEILINGm FOYER 30 T \/ OPENMABOVE Q O SHRUBS BOTANICAL/COMMON NAME A 0 24 ®T A3YOPTCHENArtemisia x'Silver Mound' Powis Castle Artemisia TN3 NI r 3TNE Ca Z° PWDR 9C]W9 rooN L.L O xroaaoz.v ++ W `Y 28 PANTRY a CEILING O N W o Calamagrostis x acutiflora 'Karl Foerster' /Feather Reed Grass y I 6068SLDR ❑ a) M LLi a W W I L aaz6aoa N _ I'1/L Daphne x burkwoodii 'Carol Mackie' /Carol Mackie Daphne I LQ PATIO 1IN ccV W Y - OITA9 Lavandula angustifolia'Munstead'/Munstead English Lavender W GA AGE o i t j a V .Y J k•. x U �" . ® 30A9Aa O Nassella tenuissima 'Pony Tails' /Mexican Feathergrass CEM REVISIONS o o MIRK DATE Description Pennisetum alopecuroides'Burgundy Bunny' /Burgundy Bunny Dwarf Fountain Grass V o° I(�rI�'' � 0�1L ** ** 'O + Ile �4 ��M�E� 00 • p0 tY L V W Y O a Pennisetum alopecuroides'Hameln' /Hameln Dwarf Fountain Grass OOoo_000 4J W W W W •L W •Y Y Y W W W •Y W Y 7 W WYY Y •Y WYYY Y YLL W W Y •Y y Philadelphus x'Minnesota Snowflake' /Minnesota Snowflake Mock Orange V V V W W V V V V V V V V c a cRhus typhina 'Tiger Eyes' /Tiger Eyes Sumac a v Sambucus nigra'Black Lace'/Black Lace Elderberry Zj JOB NO: 18 1058 d d DATE: 09.08.2020 o U DRAWN BY: KS Viburnum x burkwoodii 'Anne Russell' /Burkwood Viburnum CHECKED BY: JB 00 c ar DRAWING TITLE cc Yucca filamentosa 'Color Guard' /Adam's Needle a 0 PROTOTYPE Note: Concept Lot-House Configuration CONCEPT o PLANTING PLAN >. LLl 0 10 20 30 feet w O Q 0 c. } 2 H SHEET NUMBER U NORTH SCALE: 1" = 10' a E Ll 02 0 v Y fN 4J 0 L Q 1 Cn 1 2 1 3 1 4 15 6 7 18 9 1 10