Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CC - Approved Landscaping Plan
These documents are the property of Stack Rock Group and are not to be copied, reproduced, distributed, either directly or indirectly, used for another project or any purpose whatsoever without express and written permission of Stack Rock Group.JOB NO: DATE: DRAWN BY: CHECKED BY: # DRAWING TITLE SHEET NUMBER JB DW 09.30.2019 19-1265 D e s c r i p t i o nDATEMRK REVISIONSG:\Shared drives\Stack Rock Group\Work\2019\01-Projects\19-1265 Caven West 2\03-CAD\3.01-City Submittals\19-1265 L100 DR LandscapePlan.dwgCAVEN RIDGE ESTATES WEST 2MERIDIAN, ID1 ABCDEFGH2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 STACK ROCK GROUP - CITY REVIEW SETWILLET C HOWARD, PLA OFFICE: (208) 345.0500 EMAIL: WILL@STACKROCKGROUP.COM www.STACKROCKGROUP.COM THE GRAPHICS AND DESIGNS O N T H I S S H E E T A R E DE LIVE RAB LE S THA T RE MA IN A T A L L TI M E S PR OP E R T Y O F S T A C K R O C K G R O U P , I N C . REPRODUCTION OR REUSE OF T H I S P R O D U C T C O N T A I N E D H E R E I N I S P R O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F S T A C K R O C K G R O U P , I N C . ©2019 STACK ROCK GROUP, INC. LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St. #154 Boise, ID 83702 StackRockGroup.com PRELIMINARY NOT FOR CONSTRUCTION 09.30.19 LA-16830 RET S UBNESSEJ *OH A DIFOETATS *LICENSED LANDSC A P E A R CHITECTL1.00 LANDSCAPE NOTES PROJECT DESCRIPTION: CAVANAUGH SUBDIVISION PHASE II PROJECT OWNER/DEVELOPER:LASHER ENTERPRISES CITY:MERIDIAN LANDSCAPE REQUIREMENTS: PER CITY OF MERIDIAN LANDSCAPING REQUIREMENTS CHAPTER 11. LANDSCAPE ALONG STREETS: *1 TREE PER 35 LINEAR FEET **TREE COUNT REDUCTIONS ON E. SICILY DR. DUE TO ACHD SEEPAGE BEDS, 5 EXTRA TREES PROVIDED IN NORTHERN OPEN SPACE & ALONG PATHWAY 2.. ·(NORTH SIDE) E. SICILY DR.TREES REQUIRED:TREES PROVIDED: ·435 LF 12 12 ·(SOUTH SIDE) E. SICILY DR.TREES REQUIRED:TREES PROVIDED: ·405 LF 12 7** ·(WEST SIDE) S. PATTERN WAY TREES REQUIRED:TREES PROVIDED: ·304 LF 9 9 ·(EAST SIDE) S. PATTERN WAY TREES REQUIRED:TREES PROVIDED: ·314 LF 9 9 LANDSCAPE ALONG PATHWAYS: *1 TREE PER 100 LINEAR FEET ·PATHWAY 1 TREES REQUIRED:TREES PROVIDED: ·317 LF 3 3 ·PATHWAY 2 TREES REQUIRED:TREES PROVIDED: ·108 LF 1 2 ·PATHWAY 3 TREES REQUIRED:TREES PROVIDED: ·752 LF 8 8 ·PATHWAY 3 (S. MERIDIAN RD.)TREES REQUIRED:TREES PROVIDED: ·665 LF 7 7 LANDSCAPE IN COMMON LOTS: *1 TREE PER 8,000 SQUARE FEET ·LOT 27, BLOCK 1 TREES REQUIRED:TREES PROVIDED: ·17,482 LF 2 6 BIODIVERSITY REQUIREMENT: *A MINIMUM OF 5 DIFFERENT TREE SPECIES ARE REQUIRED WHEN MORE THAN 50 TREES ARE PROPOSED. ·PROPOSED TREES SPECIES REQUIRED:SPECIES PROVIDED: ·71 5 5 PLANT SIZING MINIMUM REQUIREMENTS: ·SHADE TREES:MIN 2" CAL, B&B ·ORNAMENTAL TREES:MIN 2" CAL, B&B ·EVERGREEN TREES:MIN 6 FEET IN HEIGHT VICINITY MAP: HIGHWAY 44 OVERLAND RD. VICTORY RD.LOCUST GROVE RD.FOCUS AREA EAGLE RD.AMITY RD. 1.REGULATIONS & STANDARDS 1.1.All contractor work shall be conducted in accordance with ISPWC (Idaho Standard Public Works Construction), 2019; and City of Meridian, ID codes, standards and state and local regulations. 2.EXISTING CONDITIONS 2.1.All utilities shall be located prior to construction and protected. Any damage to structures, utilities or concrete will be replaced at contractor's expense. 2.2.The site has many existing improvements such as underground utilities, curb and gutter, light poles and sidewalks. 2.3.See Engineer's plans for information about existing features; all drainage pipes and locations. Protect and retain drainage at all times. 3.GRADING & SITE PREPARATION 3.1.Prepare finish grades for planting by grubbing and removing weeds. If necessary apply Round-Up (or equivalent herbicide), using a certified applicator. Remove rocks and other materials over 2". 3.2.All gravel overprep to be removed and disposed of off site. 3.3.Finish grade to be smooth transition to allow for entire site to be a natural flowing space. 3.4.Fine grade lawn areas to elevations set by Engineer's plans with positive drainage away from structures. 3.5.No pooling or standing water will be accepted per industry standards. 3.SOILS 3.1.Amend soil for all new plantings: 2 part topsoil 1 part compost. 3.2.All planter beds to receive a minimum of 18" depth of screened topsoil. Spread, compact, and fine grade to smooth and uniform grade 2" below adjacent surfaces. 3.3.All lawn areas to receive a minimum of 12" depth of screened topsoil. Spread, compact, and fine grade topsoil to a smooth uniform grade 1" below adjacent surfaces. 3.4.Reuse of existing topsoil that has been stockpiled on site is permitted if: 3.4.1.Topsoil is tested and analyzed to ensure a proper growing medium. Provide additional amendments as determined by soil tests. And 3.4.2.Topsoil is to be loose, friable sandy loam that is clean and free of toxic materials, noxious weeds, weed seeds, rocks, grass or other foreign materials. 3.4.3.Topsoil should have a ph of 6.5 to 8.0. 3.4.4.If on site topsoil does not meet these minimum standards contractor is responsible for providing approved imported topsoil or improving onsite topsoil per the approval of the project manager. 3.5.If imported topsoil is used it must be from a local source and be screened free of any debris or foreign matter. Topsoil must not contain rocks, sticks, lumps, or toxic matter. 3.6.Smooth, compact, and fine grade topsoil in lawn areas to smooth and uniform grade .5" below adjacent surfaces. 3.7.Prepare finish grade of topsoil to elevations set by Engineer's plans with positive drainage away from structures. Refer to Civil Engineer's plans for grading information. 4.PLANTER BED MULCH 4.1.All planter beds to receive 3" depth of black and tan rock mulch or approved equal (crushed basalt rock), submit for approval prior to placement. 4.1.1.Install over commercial grade weed-barrier fabric, per manufacturer recommendations. 5.LAWN AREAS 5.1.Sodded, to be tall turf-type fescue or approved equal per approved by owner, regionally grown, provide same mix as seeded or approved equal (above), to be installed 6 weeks min prior to opening date. 5.2.Lay sod within 24 hrs of harvesting. Lay sod to form a solid mass with offset, tightly fitted joints on even grades. 5.3.Strip, repair and replace dead sod as needed 5.4.All lawn areas to have cut edge. 6.PLANTS 6.1.All plant material shall be installed per industry standards. 6.2.All plant material shall meet or exceed the minimum federal standards as regulated by ANSI z60.1, American Standard for Nursery Stock. Plants not meeting these standards for quality, or plants determined to be unhealthy by Owner's representative, will be rejected. 6.3.Trees and shrubs over 36" shall not be planted within clear vision triangles per city code. 6.4.Fertilize all trees and shrubs with 'Agriform' planting tablets or approved equal. Apply per manufacturers recommendations. 6.5.All landscape trees shall be pruned in accordance with the American National Standards. (Latest Edition ANSI A300) 7.IRRIGATION 7.1.Irrigation system shall be built to the following specifications: 7.1.1.Adhere to city codes when connecting to city water. 7.1.2.All irrigation material to be new with manufacturers' warranty fully intact. 7.1.3.Install outdoor rated controller. Coordinate with project manager and site electrician on exact location. 7.1.3.1.Controller to have On/Off rain switch or rain shut off device that does not alter program. Install in steel lock box with (2) keys. 7.1.4.All remote control valves (including master control valve) to have flow control device. 7.1.5.Irrigation system piping to be minimum class 200 PVC or approved equal, sleeves to be double the size of pipes located within, all wires to be contained in separate sleeves 1-1/2" dia min. 7.1.6.Use common trenching where possible. 7.1.7.All PVC located under hardscapes to be schedule 40 PVC with same req's as above. 7.1.8.All mainline pipe and wires to be buried a minimum of 18" and all lateral piping to be buried a minimum of 12" below grade. 7.1.9.All wires to be 14 gauge direct bury wire at a minimum. Size wire for correct voltage loss. 7.1.10.Supply a minimum of (2) spare wires to furthest valves from controller in all directions. 7.1.11.Sprinkler heads shall have a matched precipitation within each control circuit. Velocities shall not exceed 5 feet per second. 7.1.12.Contractor is responsible complying with all codes and paying all permits necessary.. 7.1.13.Water schedule to be provided at a min of 80% evapotranspiration as determined by the local ET. 7.1.14.All landscaping areas shall be provided with an underground irrigation system. 8.Landscaping shall be maintained according to current accepted industry standards to promote good plant health, and any dead or diseased plants shall be replaced. all landscape areas with shrub shrubs shall have an approved mulch such as bark or soil aid. 9.CONTRACTOR RESPONSIBILITIES 9.1.Estimated quantities are shown for general reference only. Contractor shall be responsible for all quantity estimates. 9.2.Refer to note 2.1 regarding damages to existing utilities & permitting note in Irrigation section. 9.3.All plant material and workmanship shall be guaranteed for a period of one year beginning at the date of Acceptance by Owner. Replace all dead or unhealthy plant material immediately with same type and size at no cost to Owner. 9.4.Landscape contractor to turn in as built drawings at the end of project. Substantial completion will not be granted until 2 copies @ 1"=20' scale are turned in and approved by owner's representative. 10.In the event of a discrepancy, notify the General Contractor. LANDSCAPE NOTES: NORTHMERIDIAN RD.N.T.S EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPXXXXXXXXXXXXXXXXXXXXXXPAT H W A Y 1 PATHWAY 2PAT H W A Y 35'-0"'5'-0"'5'-0"'E. S I C I L Y D R .S. BARTLETT WAYS. MERIDIAN RD.CAVEN WEST 2 PHASE 1 NO TREES WITHIN 10' OF ACHD SEEPAGE BED MATCHLINE MATCHLINE CONCRETE PAD FOR TRASH RECEPTACLES 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 6' PLANTER BEDS SHALL HAVE ROOT BARRIER PER DETAIL 4/L1.50 CONCRETE PATHWAY TO MATCH EXISITNG CONCRETE PATHWAY TO MATCH EXISITNG ASPHALT PATHWAY ASPHALT PATHWAY ASPHALT PATHWAY LANDSCAPE MATERIALS LEGEND: SOD LAWN, OR APPROVED OTHER NON-MOWN SEED MIX 6' WROUGHT IRON FENCE BY BUILDER - SEE DETAIL 5/L1.50 TREES BOTANICAL / COMMON NAME CONT CAL SIZE QTY REMARKS Acer platanoides `Deborah` / Deborah Maple B & B 2"Cal 25 45`h x 40`w CLASS II Fraxinus pennsylvanica / Green Ash B & B 2"Cal 9 65`h x 35`w CLASS II Ginkgo biloba `Autumn Gold` TM / Maidenhair Tree B & B 2"Cal 19 45`h x 30`w CLASS II Malus x `Spring Snow` / Spring Snow Crab Apple B & B 2"Cal 5 20`h x 20`w CLASS I Pinus flexilis `Vanderwolf`s Pyramid` / Vanderwolf`s Pyramid Pine B & B 6`-7` H 3 25` h x 12`w Tilia cordata `Corzam` / Corinthian Littleleaf Linden B & B 2"Cal 2 45`h x 15`w CLASS II PLANT SCHEDULE X 6' SOUND ATTENUATION WALL, SIMTEK ECOSTONE WALL, COLOR TO BE CHOSEN BY OWNER AT TIME OF INSTALLATION - WALL SHALL BE IN ACCORDANCE WITH UDC 11-3H-4D, SEE DETAIL 3/L1.50.EPEPEPEPMATCHLINE MATCHLINE These documents are the property of Stack Rock Group and are not to be copied, reproduced, distributed, either directly or indirectly, used for another project or any purpose whatsoever without express and written permission of Stack Rock Group.JOB NO: DATE: DRAWN BY: CHECKED BY: # DRAWING TITLE SHEET NUMBER JB DW 09.30.2019 19-1265 D e s c r i p t i o nDATEMRK REVISIONSG:\Shared drives\Stack Rock Group\Work\2019\01-Projects\19-1265 Caven West 2\03-CAD\3.01-City Submittals\19-1265 L100 DR LandscapePlan.dwgCAVEN RIDGE ESTATES WEST 2MERIDIAN, ID1 ABCDEFGH2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 STACK ROCK GROUP - CITY REVIEW SETWILLET C HOWARD, PLA OFFICE: (208) 345.0500 EMAIL: WILL@STACKROCKGROUP.COM www.STACKROCKGROUP.COM THE GRAPHICS AND DESIGNS O N T H I S S H E E T A R E DE LIVE RAB LE S THA T RE MA IN A T A L L TI M E S PR OP E R T Y O F S T A C K R O C K G R O U P , I N C . REPRODUCTION OR REUSE OF T H I S P R O D U C T C O N T A I N E D H E R E I N I S P R O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F S T A C K R O C K G R O U P , I N C . ©2019 STACK ROCK GROUP, INC. LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St. #154 Boise, ID 83702 StackRockGroup.com PRELIMINARY NOT FOR CONSTRUCTION 09.30.19 LA-16830 RET S UBNESSEJ *OH A DIFOETATS *LICENSED LANDSC A P E A R CHITECTL1.01 LANDSCAPE PLAN NORTH 0 SCALE: feet306090 1" = 30' DISTANCE VARIES 6'-0"'LAWN BUFFER S. MERIDIAN RD.SOUNDATTENUATING WALLLOT LINE10'-0"'DISTANCE VARIES MULTI-USE PATHWAY LAWN BUFFER 10'-0"'TOTAL SOUNDBARRIER HEIGHTMAXIMUM 3:1 SLOPE 4'-0"'BERMEDGE OF PAVEMENTROAD CENTER LINEEDGE OF GRAVEL SHOULDER10'-0"' GRAVEL SHOULDER These documents are the property of Stack Rock Group and are not to be copied, reproduced, distributed, either directly or indirectly, used for another project or any purpose whatsoever without express and written permission of Stack Rock Group.JOB NO: DATE: DRAWN BY: CHECKED BY: # DRAWING TITLE SHEET NUMBER JB DW 09.30.2019 19-1265 D e s c r i p t i o nDATEMRK REVISIONSG:\Shared drives\Stack Rock Group\Work\2019\01-Projects\19-1265 Caven West 2\03-CAD\3.01-City Submittals\19-1265 L100 DR LandscapePlan.dwgCAVEN RIDGE ESTATES WEST 2MERIDIAN, ID1 ABCDEFGH2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 STACK ROCK GROUP - CITY REVIEW SETWILLET C HOWARD, PLA OFFICE: (208) 345.0500 EMAIL: WILL@STACKROCKGROUP.COM www.STACKROCKGROUP.COM THE GRAPHICS AND DESIGNS O N T H I S S H E E T A R E DE LIVE RAB LE S THA T RE MA IN A T A L L TI M E S PR OP E R T Y O F S T A C K R O C K G R O U P , I N C . REPRODUCTION OR REUSE OF T H I S P R O D U C T C O N T A I N E D H E R E I N I S P R O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F S T A C K R O C K G R O U P , I N C . ©2019 STACK ROCK GROUP, INC. LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St. #154 Boise, ID 83702 StackRockGroup.com PRELIMINARY NOT FOR CONSTRUCTION 09.30.19 LA-16830 RET S UBNESSEJ *OH A DIFOETATS *LICENSED LANDSC A P E A R CHITECTL1.50 LANDSCAPE DETAILS TOP TWO STRUCTURAL ROOTS: <3" BELOW TOP OF ROOTBALL. LOWEST STRUCTURAL ROOT: <5" BELOW TOP OF ROOT BALL 612"NOTES: 1.DO NOT DAMAGE OR CUT LEADER 2.DO NOT DISTURB ROOT OR DAMAGE ROOT BALL WHEN INSTALLING TREE OR TREE STAKES. 3.TREE STAKING SHALL BE AT THE DISCRETION OF CONTRACTOR. HOWEVER ANY TREES DISTURBED FROM PLUMB DURING THE PLANT WARRANTEE PERIOD WILL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. 4.WATER PLANTS THOROUGHLY IMMEDIATELY AFTER INSTILLATION. 5.REMOVE ALL BURLAP, TWINE, ROPE, OR MATERIAL FROM THE TOP 1 3 OF THE ROOTBALL. 6.4' DIAMETER PLANTER BED/MULCH RING AROUND THE TRUNK OF THE TREE. 3" OF MULCH MIN. DO NOT PLACE MULCH WITHIN 2" OF TRUNK OF TREE. GRAFT VISIBLE ABOVE SOIL LINE SOIL LINE OF THE TOP OF THE ROOT BALL AFTER REMOVING EXCESS SOIL. 2-3" OF MULCH BACKFILL MIX SEE NOTES AND SPECIFICATIONS. COMPACT SOIL UNDER ROOTBALL TO 90% PROCTOR. BALL AND BURLAP TREE PLANTING 3/4" = 1'-0" 212" SOIL SAUCER >3" HIGH; REMOVE AT COMPLETION OF PROJECT CUT AND FOLD WIRE BASKET FROM TOP OF ROOTBALL FINISHED MATERIAL PER PLAN 329343.33-04 1 MULCH 2" MIN. AWAY FROM TRUNK OF PLANT. FINISHED MATERIAL PER PLAN BALL AND BURLAP PLANT (IF CONTAINER - GROWN PLANT WITH ROOTS LOOSENED AND PULLED OUT TO PREVENT PLANT FROM BECOMING ROOT BOUND) SOIL SURFACE ROUGHENED TO BIND WITH NEW SOIL FOLD BURLAP FROM TOP OF ROOT BALL DOWN INTO GROUND; SET TOP OF BALL FLUSH WITH FINISH GRADE 12" TO 18" FOR LARGER SHRUB ROOT BALLS, MAKE DEPTH MIN. 4" DEEPER THAN BALL) 3" DEEP MULCH MIN. NOTE: REMOVE ALL TAGS, TWINE OR OTHER NON BIODEGRADABLE MATERIALS ATTACHED TO PLANT OR ROOT MASS. BACKFILL SHALL BE 100% TOPSOIL. WATER SETTLE ALL PLANTINGS TO ENSURE PLANT ROOTBALL MAINTAINS 1 2" HEIGHT ABOVE EXISTING SOILS WHEN COMPLETE. SHRUB PLANTING 1" = 1'-0"329333.16-01 2 6 S. MERIDIAN ROAD TYPICAL SECTION SCALE: 1" = 5' CONCRETE WALL, RUNNING BOND PATTERN 1/2" = 1'-0" SIMTEK ECOSTONE WALL INSTALLED PER MANUFACTURER'S RECOMMENDATIONS DISTANCE PER MANUFACTURER6'-0"10'-0"6'-0"4' TALL BERM SLOPE CONTINUES DOWN TO SIDEWALK 4'-0"NOTES: *ALL COMPONENTS INSTALLED & SECURED PER MANUFACTURER RECOMMENDATIONS *MANUFACTURER SHALL BE SIMTEK ECOSTONE, COLOR TO BE CHOSEN BY OWNER. FINISHED GRADE PER CIVIL FINISH GRADE FOOTING PER MANUFACTURER BY BUILDER 323101-02 3 ROOT BARRIER DETAIL 1/2" = 1'-0" TREE ROOTBALL IN PLANTER STRIP ROOT BARRIER - DEEPROOT UB 18-2 ROOT BARRIER, OR APPROVED EQUAL ON (3) SIDEWALK SIDES ADJACENT SIDEWALK - SEE CIVIL PLANS NOTE: 1.ROOT BARRIER TO EXTEND THE ENTIRE LENGTH OF THE PLANTER STRIP PER PLAN. PLANTER STRIP LENGTHS VARY PER PLAN. ADJACENT CURB - SEE CIVIL PLANS ROOT BARRIER - DEEPROOT UB 24-2 ROOT BARRIER, OR APPROVED EQUAL ON CURB SIDE 2'-0"1'-6"3" DEPTH ROCK MULCH - SEE LANDSCAPE PLANS SUBGRADE 18" DEPTH TOP SOIL PER PLANS 4 TUBULAR STEEL FENCE 1/2" = 1'-0" TUBULAR STEEL POST & CAP 1" TUBULAR STEEL TOP RAIL TUBULAR STEEL BOTTOM RAIL TUBULAR STEEL PICKET CONCRETE FOOTING NOTES: 1.ALL COMPONENTS TO BE BLACK 2.INSTALL PER MANUFACTURER RECOMMENDATIONS6'-0"8' OR PER MANUFACTURER 2"2"24"9" 5 323119-04