Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fiberon - A301 Exterior Elevations
121'-0" EAVE HEIGHT 4 3 2 1 100'-0" FINISH FLOOR EXISTING DOOR TO REMAIN EXISTING METAL CANOPY & SUPPORTS TO REMAIN EXISTING METAL BUILDING ROOFING BEYOND TO REMAIN EXISTING PEMB TO REMAIN NEW PEMB METAL ROOFING TO MATCH EXISTING PREFINISHED GUTTER & RAIN WATER LEADER TO MATCH EXISTING 3HR CMU FIRE WALL, EXTEND 30" MIN. ABOVE HIGHEST ROOF, RE: FLOOR PLAN GRADE EXISTING RAMP TO REMAIN PREFINISHED GUTTER & RAIN WATER LEADER TO MATCH EXISTING PREFINISHED METAL CORNER TRIM TO MATCH EXISTING PREFINISHED METAL FLASHING @ OPENING BETWEEN BUILDINGS, BOTH SIDES NEW PREFINISHED METAL PEMB WALL PANELS TO MATCH EXISTING CONC. FOUNDATION RE: STRUCTURAL D A 100'-0" FINISH FLOOR 12 1/2 121'-0" EAVE HEIGHT 30" MIN. 3HR FIRE WALL, EXTEND 30" MIN. ABOVE HIGHEST ROOF, RE: FLOOR PLAN NEW 20GA. OVERHEAD DOOR, R-4.75 MIN, PAINT TO MATCH EXISTING, RE: DOOR SCHEDULE EXISTING METAL CANOPY & SUPPORTS TO REMAIN EXISTING METAL BUILDING BEYOND TO REMAIN EXISTING GRADE EXISTING DOOR TO REMAIN EXISTING PEMB TO REMAIN EXISTING RAMP TO REMAIN PREFINISHED GUTTER & RAIN WATER LEADER TO MATCH EXISTING NEW PREFINISHED METAL PEMB WALL PANELS TO MATCH EXISTING PREFINISHED METAL CORNER TRIM TO MATCH EXISTING GRADE CONC. FOUNDATION RE: STRUCTURAL 122'-8" EAVE HEIGHT 1 2 3 4 100'-0" FINISH FLOOR LINE OF EXISTING PEMB TO REMAIN NEW PREFINISHED METAL PEMB ROOFING TO MATCH EXISTING 3HR FIRE WALL, EXTEND 30" MIN. ABOVE HIGHEST ROOF, RE: FLOOR PLAN 30" MIN. 30" MIN. NEW 18GA. HM DOOR & FRAME, U-0.37 MIN, PAINT TO MATCH EXISTING RE: DOOR SCHEDULE GRADE CONC. FOUNDATION RE: STRUCTURAL PREFINISHED METAL CORNER TRIM TO MATCH EXISTING PREFINISHED METAL FLASHING @ OPENING BETWEEN BUILDINGS, BOTH SIDES NEW PREFINISHED METAL PEMB WALL PANELS TO MATCH EXISTING THESE DESIGNS AND DRAWINGS ARE THE EXCLUSIVE PROPERTY OF RUDEEN & ASSOCIATES ARCHITECTS, AND ARE NOT TO BE USED OR DUPLICATED WITHOUT PERMISSION. COPYRIGHT © 2019, ALL RIGHTS RESERVED. 1953 NOVEMBER 12, 2019 Fiberon Regrind Addition Addition: 420 W. Franklin Rd. Meridian, Idaho 83642 rudeenarchitects Boise + San Francisco 199 North Capitol Blvd. Suite 602 Boise, Idaho 83702 Phone 208-338-1413 Fax 208-336-0371 info@rudeenarchitects.com architecture planning project management CZC SUBMITTAL CITY OF MERIDIAN Nov. 12, 2019 SCALE: EAST ELEVATION A1 1/8" = 1'-0" 1953 A301.DWG A3.01 AS NOTED EXTERIOR ELEVATIONS SCALE: NORTH ELEVATION F1 1/8" = 1'-0" SCALE: WEST ELEVATION F8 1/8" = 1'-0"