Loading...
HomeMy WebLinkAboutL1.1CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS CONSTRUCTION LIMITS SCALE: 0 1"= 20'-0" 20 20 40 60 CERTIFICATE OF ZONING COMPLIANCE LANDSCAPE PLAN TREES NOTED SHALL BE REMOVED AND REPLACED WITH HYDRAULIC TREE SPADE. SPADE SHALL HAVE A CAPACITY FOR A MINIMUM ROOT BALL DIAMETER AS NOTED AND A MINIMUM ROOT BALL DEPTH AS NOTED. ONE FULL DAY BEFORE TRANSPLANT, ALL DECIDUOUS TREES SHALL BE SPRAYED WITH AN ANTI-TRANSPIRANT (WILT-PRUF OR EQUAL) TO ALL OF THE FOLIAGE (TOP AND BOTTOM) AS PER MANUFACTURER'S RECOMMENDATIONS. THE TREE TRANSPLANT SHALL BE DONE IN ONE CONTINUOUS PROCESS AND THE PREVIOUSLY DUG RECEIVING THE NEW LOCATION FILL. HOLE SIDES SHALL BE SCARIFIED. A PLANTING MIXTURE OF ONE PART PEAT MOSS TO THREE PARTS TOPSOIL WITH AGRO 'TRANSPLANTER', 4-2-4 (OR APPROVED EQUAL, USE AS PER MANUFACTURER'S RECOMMENDATIONS) SHALL BE MIXED WITH WATER TO FORM A SLURRY. THE SLURRY MIXTURE SHALL FILL ANY VOIDS AROUND THE ROOTBALL, ELIMINATING ANY AIR POCKETS. AGRIFORM PLANTING TABLETS 20-15-5 (OR APPROVED EQUAL) SHALL BE INSTALLED. TABLET QUANTITY BASED UPON PLANT SIZE AS PER MANUFACTURER'S RECOMMENDATIONS. TREE SPADE SIZE DECIDUOUS TREE - TRUNK DIAMETER EVERGREEN TREE - HEIGHT 44 INCHES 2 TO 4 INCHES 5 TO 7 FEET 66 INCHES 4 TO 6 INCHES 7 TO 10 FEET 92 INCHES 6 TO 10 INCHES 12 TO 15 FEET TRUNK DIAMETERS ARE MEASURED USING A CALIPER, SIX INCHES ABOVE THE GROUND FOR TREE FOUR INCHES IN DIAMETER OR SMALLER AND 12 INCHES ABOVE THE GROUND FOR TREES WITH A LARGE DIAMETER. NOTE: THE INDUSTRY STANDARD IS 1:10. (10 INCHES OF ROOTBALL FOR EVERY INCH OF TRUNK CALIPER) TREE TRANSPLANT NOTES: TREE PROTECTION NOTES: 1. PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE) OF THE TREES TO REMAIN ON SITE BY: a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE TREE TO BE PROTECTED PRIOR TO DEMOLITION, CONSTRUCTION, OR ANY SITE WORK. b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION. c. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR ANYWHERE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE WASHOUT AREAS. d. NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION AREA. e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK. f. NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL WITHIN THE CRITICAL ROOT ZONE. g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS. 2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY: a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES. b. HAVING TREES PRUNED BY A LICENSED ARBORIST. 3. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE MITIGATED USING THE MITIGATION STANDARDS PER THE MERIDIAN CITY CODE AS PER SECTION 11-3B-10. 4. 5. SEE TREE MITIGATION NOTES FOR ADDITIONAL INFORMATION. TREE MITIGATION NOTES: 1. THE EXISTING TREES TO BE RELOCATED ARE AS FOLLOWS FROM THE INTERIOR OF THE SITE (AS NOTED ON PLAN): - (5) 6" CAL. HONEYLOCUST - (1) 6" CAL. MAPLE - (1) 6" CAL. FLOWERING PEAR - (8) 6" CAL. FLOWERING CRAB - (2) 6" CAL. SWEETGUM - (1) 6" CAL. SPRUCE TOTAL CALIPER INCHES OF TREES RELOCATED = 108 CALIPER INCHES TOTAL CALIPER INCHES THAT CAN BE USED FOR REQUIRED LANDSCAPING = 72 CALIPER INCHES AREA ONE - SHEET L1.0 AREA TWO - SHEET L1.1 SHEET OF Sheet Number Drawing Title SEP 2019 RE 2018-04 - 19051 LP JOB NO: DATE: DRAWN BY: CHECKED BY: Seals C O P Y R IG H T All rights reserved. Reproduction without written permission of Architecture Northwest, PA is unlawful and subject to criminal prosecution. RANADLL HAVERFIELD A.I.. A 224 16th AVENUE SOUTH NAMPA, IDAHO 83651 OFFICE: (208) 467-3377 FAX: (208)467-4343 www.arcnw.com ARCHITECTURE N O R T H W E S T, P A MRK DATE DESCRIPTION LA-238 S T A T E O F I D A H O L I C E N S E D L A N D S C A P E A R C H I T E C T R O D N E Y P . E V A N S J R . PRELIMINARY NOT FOR C O N S T R U C T I O N M E R I D I A N , I D A H O T E N M I L E C H R I S T I A N C P H A S E O N E A D D I T I O N F O R: reandpartners.com + 208-514-3300 + 1014 S. La Pointe, Boise, Idaho 83706 LANDSCAPE ARCHITECTURE + URBAN DESIGN + LAND PLANNING + GRAPHIC COMMUNICATION + PROJECT MANAGEMENT 1. RETAIN AND PROTECT EXISTING LANDSCAPE 2. RETAIN AND PROTECT EXISTING TURF 3. RETAIN AND PROTECT EXISTING TREE 4. EXISTING TREE TO BE RELOCATED, SEE TREE MITIGATION AND RELOCATION NOTES 5. PROPOSED TURF AREA, PATCH BACK AT EXISTING TURF 6. PROPOSED BICYCLE STORAGE 7. PROPOSED POND 8. PROPOSED COVERED ENTRY BY OTHERS 9. PROPOSED BUILDING ADDITION BY OTHERS 10. EXISTING 30' WIDTH SEWER EASEMENT 11. RELOCATED PLANT MATERIALS FROM BUILDING EXPANSION AREA CALLOUT NOTES # CALLOUT NUMBERS REFER TO NUMBERED NOTES BELOW 11 2 2 1 4 4 4 2 2 2 1 CZC LANDSCAPE PLAN L1.1 1 1 1 1