Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A2.11 FLOOR PLAN
Sheet No. Project No. Client Approval: Design Phase: Document Phase: Architect Stamp Issue Date: Drawn By: Checked By: Revision ID ChID Issue Name Date 01 02 01 02 ADDENDUM 02 ADDENDUM 03 7/17/2018 7/27/2018 AS JD FLOOR PLAN A2.11 COPYRIGHT © 2018 SLICHTER|UGRIN ARCHITECTURE JULY 2018 18048 2720 W CHERRY LN MERIDIAN ID 83642 VISION QUEST MEDICAL CENTER THIS DRAWING DEPICTS IDEAS, DESIGNS, PLANS, AND DETAILS WHICH ARE PROPRIETARY TO SLICHTER|UGRIN ARCHITECTURE. THEY WERE CREATED, DESIGNED, AND DEVELOPED FOR USE SOLELY IN CONNECTION WITH THE PROJECT SHOWN ON THIS DRAWING AND MAY BE USED ONLY WITH THE PERMISSION OF SLICHTER|UGRIN ARCHITECTURE. NO TRANSFER OF ANY RIGHTS THERETO IS INTENDED OR GRANTED BY DELIVERY HEREOF, AND EXCEPT UPON THE WRITTEN PERMISSION OF SLICHTER|UGRIN ARCHITECTURE. THIS DRAWING IS NOT TO BE DISCLOSED IN ANY WAY FOR PROJECTS OTHER THAN THE SPECIFIED PROJECT. BID/PERMIT SET Print Date: Monday, September 30, 2019 SEPT. 30 2019 FURN FURN FURN DW A15 A16 A13 A14 A12 A9 104 117 A5 A10 A6 A11 A9 125A A8 123 A5 A6 A6 A5 A6 A5 A2 100 A13 A14 S04 122 121 125B 126 127 128 124 131 130 129 116 115 114 119 118 120 S03 113 111 110 109 A3 A4 A13 A14 A5 A6 A9 105 108 112 106 107 B B F FE F 2'-0" 4'-0" 2'-0" 2'-0" 4'-0" 12'-0" 3'-4" 2'-0" 13'-4" 29'-4" 12'-4" 19'-8" 47'-8" 15'-7" 17'-7" 12'-9" 4'-3 5/8" 10'-4 3/8" 2'-0" 7'-11" 11'-11 1/8" 8'-4 7/8" 8'-1/8" 7'-9 1/4" 6'-5 1/8" 8'-4" 14'-6 7/8" 3'-1/8" 5'-0" 4'-7 3/8" 14'-11" 9'-10 1/4" 5'-6 5/8" 9'-2 5/8" 8'-7 3/8" 8'-11" 5'-6 1/2" 12'-4 7/8" 12'-4 7/8" 4'-10 7/8" 12'-4 1/4" 79'-8" 3'-6" 4'-4 1/2" 10'-5" 4'-11" 10'-4 1/2" 14'-3" 4'-1 1/2" 9'-2 5/8" 9'-6" 4'-10 1/2" 79'-8" 8'-0" 66'-0" 3'-4" 76'-0" 7'-10" 21'-0" 8'-11" 8'-11" 8'-11" 4'-10 7/8" 3'-4" 20'-0" 3'-4" 2'-0" 4'-0" 17'-4" 3'-4" 9'-4" 8'-0" 2'-0" 3'-4" 2'-0" 8'-0" 2'-4" 19'-8" 4'-4" 26'-4" 3'-4" 13'-8" 77'-4" 10'-8 3/8" 10'-8 1/2" 1'-4" 12'-8" 11'-8" 22'-8" 22'-8" 8'-8" 2'-4" 8'-0" 2'-4" 3'-4" 16'-0" 3'-4" 3'-4" 4'-0" 8'-0" 4'-0" 3'-4" 1'-4" 5'-4" 2'-0" 24'-5" 2'-6" *4'-0" MIN 12'-8 1/2" 12'-4 7/8" 9'-7/8" 10" 10" 5'-2"(VERIFY) 1 A4.11 1 A4.11 #DrgID #LayID #DrgID #LayID A A3.11 C A3.11 B A3.11 D A3.11 O K P L A8.14 G H A8.11 F D E C A8.11 M K A8.11 L J B I A A8.11 H G C D A8.12 B F A E A8.12 H C G D A8.13 B F A E A8.13 K I L J A8.12 N O M P A8.12 N I M J A8.13 O K P L A8.13 F A E B A8.14 Q U R A8.13 R T Q S A8.14 M I N J A8.14 H D G C A8.14 A C B A8.15 T A8.13 S F D E A8.15 WALL S608-20 S608-20 W608 W408 W408 W408 TB-6 POSTAGE METER COPIER BENCH BENCH WH E. TANK F.S TTB LCP F.D. F.D. F.D. COORDINATOR RM 121 OFFICE MANAGER RM 122 PRETEST RM 112 VISUAL FIELD RM 111 EXAM RM 113 EXAM 1 RM 116 EXAM 4 RM 131 EXAM 5 RM 130 EXAM 2 RM 115 EXAM 3 RM 114 EXAM 6 RM 129 EXAM 8 RM 127 EXAM 9 RM 128 EXAM 7 RM 126 CONTACT LENS FITTING RM 106 SPECIAL TESTING RM 107 UNISEX RM 109 PHYSICIANS OFFICE RM 110 MECH. RM 108 FILING RM 101 TECH STATION RM 132 BREAK RM 125 UNISEX RM 124 LAB RM 120 UNISEX RM 119 UNISEX RM 118 RECEPTION RM 102 OPTICAL RM 103 WAITING RM 100 HALLWAY RM 104 HALLWAY RM 105 HALLWAY RM 117 ENTRY RM 123 HALLWAY RM 133 1 1 A A 2 2 1 A8.16 2 A8.16 3 A8.16 5 A1.11 2 A4.11 2 A4.11 A. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GYPSUM WALLBOARD / STEEL STUD PARTITION WALLS. B. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF FINISHED MASONRY FOR CMU AND/OR BRICK. C. FOR FLOOR FINISHES, REFER TO THE ROOM FINISH SCHEDULE, SHEET A8.01 AND FLOOR FINISHES PLAN, SHEET A8.11. D. UNLESS NOTED OTHERWISE ALL GYPSUM WALLBOARD / STEEL STUD PARTITION WALLS SHALL HAVE A 6” STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. E. FOR SIZES OF MARKERBOARDS AND TACK BOARDS, REFER TO THE SPECIFICATIONS DIVISION 10 SECTION 101100 VISUAL DISPLAY UNITS. LENGTHS ARE INDICATED ON THE FLOOR PLANS AND MOUNTING HEIGHTS ON THE INTERIOR ELEVATIONS. F. REFERENCE SHEET G0.03 FOR PROJECT INFORMATION AND 2015 IBC CODE & OCCUPANCY PLAN. G. REFERENCE SHEET A5.01 FOR INTERIOR PARTITION ASSEMBLIES, ACOUSTICAL AND FIRE RESISTIVE CONSTRUCTION REQUIREMENTS. H. SEE ENLARGED PARTIAL FLOOR PLANS FOR ADDITIONAL WALL TYPES. I. FILL ANY HOLES IN SLAB WITH PATCHING & SELF-LEVELING COMPOUNDS PRIOR TO NEW FLOORING INSTALLATION. COORDINATE WITH DIVISION 09 OF THE SPECIFCATIONS. J. ALL INTERIOR WALLS SHALL BE S308-20 UNLESS OTHERWISE NOTES. KEYED/REFERENCE NOTES: KEYED NOTES: 6.22 CONTRACTOR TO PROVIDE 19/32" PLYWOOD BACKING PANEL TO ENTIRE SOUTH SOUTH WALL TO 8'-0" A.F.F 11.01 WALL MOUNTED TELEVISION (RECESSED) COORDINATE ALL ROUGH INS WTH THE ELECTRICAL DRAWINGS. 12.01 OWNER FURNISHED CONTRACTOR INSTALLED, LIGHTED DISPLAY CABINETS SCALE: 3/16" = 1'-0" 1 MAIN FLOOR PLAN 11.01 11.01 12.01 12.01 12.01 6.22 TOTAL BUILDING: 5,580 SQFT NORTH GENERAL NOTES: