Loading...
HomeMy WebLinkAboutCC - Geotech ReportSITE CONSULTING, LLC Trilogy Development Mr. Shawn Brownlee 9839 West Cable Car Street, #101 Boise, Idaho 83709 Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 Re: Geotechnical Recommendation Report Gander Creek Subdivision Development South of McMillan Road Meridian, Idaho Shawn: and West of McDermott Road March 7, 2019 Page 1 of 31 File 19010-B As per your authorization, on December 4-7, 2018, SITE personnel logged and sampled eighteen new test pits on your proposed Gander Creek Subdivision development. This project is located on the southwest corner of McDermott and McMillan Roads in Meridian, Idaho. The project consists of FIVE tax parcels identified on the Ada County Assessor website as follows. The proposed combined property is outlined in green: Geotechnical Services / Soil Testing & Inspection Services a) to CZ a # Parcel # Acres 1 SO432110100 7.59 2 SO432110450 43.86 3 SO432110565 42.25 4 SO432141800 16.95 5 SO432110500 6.43 TOTAL 117.08 The proposed combined property is outlined in green: Geotechnical Services / Soil Testing & Inspection Services a) to CZ a SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 This report is to replace our prior Geotechnical Feasibility Report (19010-A) written by SITE in January 2019. Test pit logs, well logs, and all other data from the original report are included herein. According to information supplied by the client, this project will include lots for single- family residences and ACHD right of ways. Access will be gained from McMillan Road to the north and a future arterial sized right of way to the west. Undeveloped farmland surrounds this property on all sides. It is noted that the future Highway 16 right of way is along the east property boundary. Nine Mile Creek bisects the property from east to west and is reported to flow year-round. Based upon our research, observations, and laboratory test results, the site is acceptable for the proposed residential subdivision development. Recommendations for construction are included herein. We appreciate this opportunity to be of service. When appropriate, we would like to discuss continuing our role as geotechnical consultant during construction. Please contact our office if additional information or services are required. Respectfully submitted, Bob J. Arnold, PE SITE Cons Geotechnical Services / Soil Testing & Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC TABLE OF CONTENTS INTRODUCTION.....................................................................................................4 Purposeand Scope.................................................................................................4 Authorization...........................................................................................................4 Warranty and Limitations.........................................................................................5 RESEARCH& BACKGROUND.............................................................................5 General...................................................................................................................5 VicinityMap.............................................................................................................6 Observed Subsurface Conditions............................................................................6 DESIGN & CONSTRUCTION RECOMMENDATIONS...........................................7 GeneralEarthwork..................................................................................................7 Excavations.............................................................................................................8 PavementSection...................................................................................................9 BridgeFoundation System......................................................................................9 Residential Foundation System...............................................................................10 StormWater............................................................................................................10 Slabon Grade Concrete..........................................................................................11 UndergroundUtilities...............................................................................................11 Inspection& Testing................................................................................................12 ContractorInspections............................................................................................12 GeneralComments.................................................................................................13 APPENDIX..............................................................................................................14 &F a) 0Z CZ a, Geotechnical Services / Soil Testing & Inspection Services Z SITESULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 N INTRODUCTION Purpose and Scope This report documents our geotechnical investigation and resulting recommendations for the proposed Gander Creek Subdivision. This project will be constructed on a property located south of McMillan Road and west of McDermott Road in Meridian, Idaho. The purpose of this report is to document the investigation of subsurface soil conditions and provide recommendations for building single family residential structures and a residential subdivision. Geotechnical test pits have been excavated based upon preliminary drainage plans provided by the client. It is anticipated that these test pits represent conditions across the site. Our field investigation included subsurface exploration by means of rubber tire and track mounted backhoes supplied and operated by Wood Brothers Trucking. Soil samples were gathered, and test pit logs generated during the field exploration. After the field investigation and laboratory testing was completed, all available field and laboratory test data was reviewed, the general data and assumed design information was evaluated, and this report was prepared. This report summarizes our research and recommendations regarding the geotechnical aspects of the project. Monitoring wells were installed in all test pits for a future groundwater monitoring program. Groundwater monitoring data will be reported in an additional report when available. Authorization Authorization to proceed with the original geotechnical investigation was received from the client in March 2018. Authorization to proceed and the use of the provided recommendations indicate the client's and the design team's acceptance of the scope of work, warranty, limitations & general conditions provided herein and within our standard geotechnical proposal. a Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Warranty and Limitations Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 The exploration and evaluation of subsurface conditions documented herein is considered sufficient to form a basis for the provided recommendations. The provided recommendations are based on the available soil information and preliminary design details either assumed or furnished by the client and his civil design team. It is warranted that these recommendations have been promulgated after being prepared in accordance with locally accepted professional engineering and geotechnical engineering practice. No other warranties are implied or expressed. RESEARCH & BACKGROUND General As per your authorization, in December 2018, SITE staff observed the excavation of eighteen test pits on the subject property. At the time of exploration, the entire site was flat, dry, and accessible with the exploration equipment. Monitoring wells were installed prior to backfilling the test pits. During excavation, our staff gathered representative samples from the spoil piles. The samples were field classified, labeled with pit number and depth, and transported to the laboratory for additional testing. Sieve Analysis, Moisture Content, and Liquid Limit, Plastic Limit & Plasticity Index testing were performed on selected samples. All tests were performed in general accordance with the appropriate ASTM test methods. It is noted that these test pits included replacement of six monitoring wells originally installed by SITE on the northern half of the property in 2017. The original wells were mostly destroyed or damaged by onsite farming activities. M, Q) bA a Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Vicinity Map Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208440-6276 Prior to our field investigation, SITE obtained an aerial photo of the subject property from landprodata.com. This aerial was used with a preliminary site plan to locate the subject property and position the test pits. The aerial photo reveals the subject property is surrounded by rural properties and farmland. This Aerial Photos with test pit locations shown is included in the Appendix. Observed Subsurface Conditions Subsurface conditions in the test pits were generally similar. The topsoil ranges in depth from two to five feet and typically consists of lean clay, silt, and sand in varying percentages depending upon location. Many samples were tested, and no fat clay was identified. The rootzone / organic layer is typically 4-8 inches deep with deeper historical cultivation evident to 1.0-1.5 feet. Below the topsoil, silty sand or sandy silt soils are typical with gravels and clay contact varying. Gravels were contacted as shallow as 1.5 feet and as deep as five feet. Gravels are coarser and include cobble sized rock at greater depths. Fines within the gravels decrease with depth but did included lean clays at 12 to 15% by mass. The sand and gravel layer extends to below the bottom of our test pits which were terminated within one foot of contact with the static groundwater. The is a difference in groundwater elevation of over eight feet across this property. Groundwater south of Nine Mile Creek was very consistent, observed at seven to eight feet below the ground surface. North of Nine Mile Creek the groundwater ranged from 8 to 13 feet deep. Only a portion of this variation can be attributed to surface elevation differences. Groundwater data will be measure monthly starting in mid-March and reported again in later groundwater monitoring reports. Well logs for three adjacent properties were obtained from the IDWR website. These logs confirm our onsite measurements and also indicate static groundwater is 6-8 feet deep. The well logs are included in the Appendix. Vol Q) to CZ C1. Geotechnical Services / Soil Testing & Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC DESIGN & CONSTRUCTION RECOMMENDATIONS General Earthwork All native soils that are free of organic matter and expansive clays are acceptable for use as fill. After proper grubbing, the native lean clay, silty sand or sandy silt, and all soils containing gravel removed from the right of ways can be utilized as structural fill to fill residential lots. These soils may not meet ACHD's minimum inplace density requirement of 100 pcf for structural filling within the right of way. This can be corrected by blending with deeper sand and gravel soils. Blending may also improve working moisture contents and increase the percolation rate of surface water through the completed building pads. Removal of the majority of the organic materials will require grubbing of 4-6 inches of surface soils. This is required in all areas to receive structural fill. Deeper excavation may be required along irrigation ditches, where large trees and soft wet areas are present, and anywhere the former sugar beet crop was abandoned. The depth of grubbing is to be adjusted and inspected during construction to ensure that organic materials are properly removed from beneath future pavements and structural fills. Inspection by the project geotechnical engineer should confirm that all organic material is removed. If used for fill, the surface clay soils will require moisture contents within two percent of optimum for effective compaction. When well compacted these soils prevent percolation. This condition combined with other construction and homeowner practices may lead to water accumulating in crawlspaces. Clay and silt soils will easily become too wet or too dry for effective compaction and can be expected to perform poorly if wet and subjected to rubber tired equipment. Both concerns can be addressed by blending with deeper sand and gravel materials. If construction is to occur during wet weather or wet surface soil conditions, low-pressure, (tracked), construction equipment is recommended. Rutting caused by the contactor using rubber -tired equipment on a wet subgrade can be expected and should be repaired at contractor expense. This t\ information is to be supplied to earthwork contractors prior to construction. a Geotechnical Services / Soil Test/ng & Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmaii.com - 208-440-6276 CONSU LTI NG, LLC Structural fills less than three feet deep are to be compacted to 95 % of the maximum dry density by ASTM D698, Standard Proctor. For deeper fills, such as ditch backfill, and fill intended to contain rerouted irrigation canals or storm water runoff, fill materials are to be compacted to 100 % of the maximum dry density. If structural fill is to be placed on residential lots or building pads, the fill is to extend laterally outside foundations a distance equal to the depth of structural fill. Granular structural fill should be placed beneath future slab on grade concrete including driveways, patios, and sidewalks. Structural fill should be placed in uniform, thin horizontal lifts, moisture conditioned as necessary, and compacted to the above requirements. Compaction testing to confirm proper compaction is recommended. Visual inspection is also required to confirm stability and the lack of soft, deflecting, or rutting areas. Fill can pass compaction tests and still be rejected if it fails visual inspection. Excavations Shallow excavations and trenches that do not exceed four feet in depth may be constructed with side slopes approaching vertical. Below this depth it is recommended that slopes not exceed a vertical to horizontal ratio of one to one. The ability of soils on site to maintain a vertical or near vertical excavation over any extended period can be quite variable. This information is provided for planning purposes. It is our opinion that maintaining safe working conditions is the responsibility of the contractor. Jobsite conditions such as soil moisture content, weather condition, earth movements and equipment type and operation can all affect slope stability. All excavations should be sloped or braced as required by applicable local, state, and federal requirements. `� a) bA CZ a, Geotechnical Services / Sofl Testing & Inspection Services SITE CONSULTING, LLC Pavement Section Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 R -Value samples were gathered and tested from TP -2 and TP -16. For phase one of this development, based upon an R -Value result of R=12 and the indicated Traffic Indexes, SITE recommends the following sections for residential streets within this subdivision. Material Layer Subdivision T1=6 Collectors T1=8 HMA Pavement 2.5" 3.0" Base Coarse %" minus 4.0" 4.0" Sub base Pitrun 12.0" 18.0" ACHD should be contacted to confirm the utilized traffic Index of T1=8 is correct for McMillan Road and the future collector or arterial to the west of the property. Materials meeting the requirements of ISPWC & / or ACHD are required for all work within this project. Bridge Foundation System This project may include multiple bridges over Nine Mile Creek. Bridge foundations that are extended to the native sand and gravel present at greater than eight feet deep can be designed for a bearing capacity of 3000 psf. Only granular materials should be used to backfill bridges or culverts. Native sand and gravel or imported material meeting the requirements for ISPWC subbase are recommended. Based on using native sand/gravel or imported pitrun type material bridge backfill, retaining walls free to rotate should be designed using equivalent fluid pressure of 45 psf/f. Walls restrained at the top should be designed using equivalent fluid pressure of 60 psf/f. Both values assume backfill is level for a distance equal to the height of the wall. Soil density of 120 pcf can be assumed for additional soil surcharge. A coefficient of friction of 0.35 is recommended for the native sands. L bn M a Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Residential Foundation System Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 The proposed single-family residential structures may be supported on conventional, continuous, and isolated pad foundations founded upon the native soils or upon structural fill extending to these soils. Based upon proper placement and compaction of structural fill, bearing pressures of up to 1500 psf are allowed for foundations founded on the native soils or upon properly placed and compacted structural fill. Either crawlspaces or slab on grade floors are acceptable. If clay soils are present at the foundation support elevation a geotechnical engineer should be retained for site specific recommendations. Foundation drains are required within this development. It is recommended that foundation drains and roof runoff be directed to an onsite infiltration pit that extends to at least ten feet deep and is located at least 15 feet from the nearest foundation. Roof runoff is not to route through foundation drains. Foundation embedment depth is to be at least 24 inches below outside adjacent grade. Foundation outside crawlspaces are to be sealed / waterproofed with brush or spray on foundation mastic. No basement is allowed without lot specific geotechnical/groundwater study. Storm Water Based upon the anticipated depth to seasonal high groundwater, storm water can be addressed with surface detention or drainage facilities. Percolation rates through the near surface soils can be expected to be quite variable based upon clay content at the point of injection and a shallow, weak cemented layer. For design purposes a perc rate of P=3 in./hr. is recommended. It is to be confirmed that any cemented layer present at the injection site is penetrated at the time of construction. If over excavation is required, additional filter sand or free draining pitrun can be used to backfill excessive depth caused by over excavation. Confirmation of perc rate at the time of construction by field testing is recommended. Pre -design perc testing has been scheduled and will be completed as soon as the farms fields will support a water truck. The above design perc rate will be modified if onsite testing so indicates. Geotechnical Services / Soll Testing & Inspectlon Serv/ces SITE CONSULTING, LLC Slab on Grade Concrete Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmaii.com - 208-440-6276 Care must be taken so that all excavations below both interior and exterior slab on grade concrete are properly backfilled in accordance with the structural fill recommendations. Trenches and wall backfill areas are to be filled in lifts and benched each lift so that fill is not placed against a vertical soil face greater than three feet tall. Testing is to confirm that compaction has been achieved. Areas of excessive yielding should be excavated and backfilled with structural fill. Any fill used to increase the elevation of slab on grade concrete should meet the requirement for structural fill. Due to the presence of surface clays, slab on grade floors, sidewalks, patios, driveways, garage floors and all other Portland cement concrete pavements should be placed atop a mat of at least six inches of granular structural fill materials. This depth is to increase to one foot when concrete is to be placed over Fat Clay soil. This is required to prevent seasonal heaving of pavements. Mat material should all pass a 3/4 -inch sieve and should contain less than seven percent passing the # 200 sieve. The mat shall be compacted to the requirement for structural fill. Underground Utilities It is not anticipated that large excavators or small backhoes will experience any difficulties excavating the onsite materials encountered on the property. No bedrock formation was encountered on the subject property. Well logs from IDWR indicate the high static water level is greater than 4-8 feet or more below the surface in wells near the property therefore dewatering may be required for deep utility installation. �I Geotechnlcal Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Inspection & Testing Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 A qualified engineer or his representative should monitor fill placement to ensure the work is performed in accordance with these recommendations. For mass filling, field nuclear moisture - density testing shall be performed on each lift of compacted fill, one each filled residential lot or building pad. Trench backfill and right of ways are to be tested to ACHD and / or ISPWC requirements. It is noted that structural fill can pass compaction tests and still be unacceptable if pumping, rutting, or deflecting under vehicle or foot traffic. Contractor Inspections This report has been prepared with the intent to provide specific design information to the developer and the civil engineering consultant. It is not intended to act as any contractors "Due Diligence" or subsurface inspection prior to estimating construction costs or actual construction. With permission, the contactor(s) can utilize the onsite wells for their own evaluation of groundwater. Q) bn M a, Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC General Comments Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 After the plans and specifications for construction are completed, it is recommended that this consultant be provided the opportunity to review the final design and specifications. This review will confirm that the earthwork recommendations have been properly interpreted and implemented. At that time, it may be necessary to submit supplementary recommendations. This review is a part of this service and will not result in additional invoicing unless additional research and recommendations are needed. Testing and inspection services are recommended herein. Proper quality control during construction is required to confirm materials and methods and thereby obtain a desirable finished product. Monitoring and testing should also be performed to verify suitability of materials used for structural fills and to confirm proper demolition, subgrade grubbing, subgrade stability, and proper placement and compaction of fills. Any deviations from the herein described subsurface conditions must be brought to the attention of this consultant. This report has been prepared for the exclusive use of the client and their retained design consultants. Findings and recommendations within this report are for specific application to the proposed construction described herein and apply only to the property identified. Client may duplicate this report as needed or additional copies will be provided upon proper client authorization. Appendix Follows Geotechnical Services / Soil Testing & Inspection Services Q) aA ct 0, SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 Prelimina Plat Bailey Engineering Cz a Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 AERIAL PHOTO .. . . . . . _ Google Earth Geotechnical Services / Soil Testing & Inspection Services SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC ADJACENT WELL LOGS VSE TYPEWRState of Idaho 1< r ITER OR BALL POINDepartment of Water Administration T PEN II I, WELL DRILLER'S REPORT State law requires that this report be filed with the State Reclamation Engi;necr '�71jY within 30 days alter completion or abandonment of the well, oa 1. WELL OWNER Name 2- W U4-`r--j-Static ?. WATER LEVEL er AOlginisha water Imal --r- feat below land surface Flowing? U Yes U No G.P.M. flow TemperaNn_ F. Quality Artesian closed In prossure___p,ai. Controlled by U Valve U Cap ❑ Plug /� Address tat -111-4 -" __ Owner's Permit No. 2 NATURE OF WORK . New well ❑ Deepened O Replacement ❑ Abandoned (describe method of abandoning) O. WELL TEST DATA li(pump 13 0.11. U Other ONrheret(Il.M. Draw Dewn ours uenpw () 3. PROPOSED USE 0& Domestic ❑ Irrigation U Tet ❑ Municipal O Industrial ❑ Stock S. LITHOLOGIC LOO 32069 . D t, FroeDnepT o M.—W vweN. 4. METHOD DRILLED f)D Cable ❑ Rotory ❑Dug ❑Other J .� � a 6. WELL CONSTRUCTION Diameter of hole --L inches Total depth 100 feet Casing schedule: U Steel ❑ Concrete Thkhnw Olaeewer � Frain q TGo incy . G Inches -7--a— feet Meet --.-- irdw Inches fact feet rnchas Indra: fast _..feet ---__-_ Inches _— inches _ _ feet _fen Inches inches feet _fast Was a pack. or seal used? ❑ Yea IN No Perforated?❑ Vee m No How Perforated? ❑ Factory ❑ Knits ❑ Torch Slzeofpedoration _ Inchosby_ Inches Number From To parforations feet feet perforations feet foot perforations feet feet Well screen Installed? ❑ Yea ie No Manufacturer'. name Type_ Model No, Olameter_Slof dn— Set hem feet to__fen Diameter_ Slot size_. Set from feet to — feet Gravel packed? ❑ Yes 4 No Size of gravel Placed from-- feet to feet Surface Beal? ❑ Yes ❑ No To what depths feet Material used In seep U Cement grout 111 Puddling clay "— --- - - •- ------" '- 6. LOCATION OF WELL Sketch map location must agree with written location. N ,y w E County aePa� 10 - O, Wore staro.d p � 3 � • 7/ ! f(nidte0 ,�-. 4 - 7 11. DRILLEfl'S CERTIFICATION This well was drlllod under my supervision and this report Is trua to the best of my kewwlndga. DOW. or Firma Name Number %l• / 4'XsC ,,,, II','' 4 T. It Nit, R-1—Am Add— _1L-tl -��•• �C7-_d %/ _ Sleeved BY Oats USE ADDITIONAL SHEETS IF NECESSARY FORWARD THE WHITE, BLUE, AND PINK COPIES TO THE DEPARTMENT Geotechnical Services / Soil Testing & Inspection Services aaa� L' Q) bA a SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 •r_ Form 238-7 IDAHO DEPA NT OF WATER RESOURINCEIVE t te? Office Use Only WELL DRILLER'S REPORT Inspededby 1. WELL TAG N0. D 6 9 O R E C E I V E D FEB .16 Twp — Rge___Sec 9 /4____ Iva �va RESOURCE — DRILLING PERMIT N0. b �i-�- 1. WELL REeiO Lak Lon Other IDWR No. 2 3 1999 ❑ Pump ❑ Bailer OAtr owing Artesian' 2. OW ER' r.xa ahem. 01-d—Pemping Lae(_ Time Name Department d Water R # Address city—M, State Zip $3&412 Water Temp. 0 loom tale temp. 3. 'LOCATION OF WELL by legal description: Water Oual test or commants: s Sketch map location must agree with written location. 1^00In DepthfirsiWaterEncoumar__V_ _. 17 N irLjr%i nfmi• r At:. Twp._--! North or South ❑ W K a Rge. _IEast ❑ or West A Sec._�� 1/4 y5LJ-lt4 _AF1/4 Gov't Lot _ County At4 Lac Long: s Addrf ss of Well Site 't` �� •r lJ/��) 1(�-�+A 1 C L no city L -(Gne a Ne aunt N oN Y b Roo v lawl Lt. Blk, Sub. Name 4. USE: Domestic .11Municipal 11Monitor ElIrrigation O hermal ❑ Injection ❑ Other 5. TYPE OF WORK check all that apply (Replacement etc,) K Ndw Well 11 Modify ❑ Abandonment ❑ Other 6. DRILL METHOD ❑ Ail Rotary Q%Cable O Mud Rotary ❑ Other 7. SEALING PROCEDURES Was drive shoe used? * O N Shoe Depth(s) 32_ Was drive shoe seal tested! P(Y❑ N Howl 8. CASING/LINER: Dleeeter From To G.W..I Geo..Qahrriar Ceeing Liner WelaeO�° eae0 O r3� ❑ ❑ 0 ❑ ❑ Cl ❑ ❑ ❑ Length of Headpipe - Length of Tailpipe 9. PERFORATIONS/SCREENS . Pedoiations Method Screens Screen Type 10. STATIC . WATER LEVEL OR ARTESIAN- PRESSURE: If: below ground � Artesian. pressure. S lb. Depth' flow encountered It, Describe access po I or control devices: �Ia► � Pj�Oy�,�,aNIf I Uii` I From I To I Remarks: Llthologyr Water Quality a Temperature I v I N I Date:. Started I`.2 - 13. DRILLER'S CERTIFICATION I/We certify that all minimum wall construction standards were compiled with at he time the rig was removed, Comparty Na Firm No39y Firm Offida Date and Driller or Operabr Data (Sr eaa / Rm oiW a Opera. ) FORWARD WHITE COPY T0. WATER RESOURCES Geotechnical Services / Soil Testing & Inspection Services ZSI TE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 Form 238-70 IDAHO DEPARTMENT OF WATER RESOURCES 6/02 WELL DR]ILLER'S REPORT 1. WELL TAG N0. D (%D35:5Q DRILLING PERMIT NO. _ Water Right or Injection Well No. 2. OWNER: ((//� Name KB')U Address MLI aAMA6 City w Slate Zia . 3. LOCATION OF WELL by legal description: You must provide address or Lot. .BBlkk. Sub. or Directions to well. Twp. E North A( or South ❑ RgeSec. Sec. East ❑ r 4 1/4 114 �1/4 GDVt Lot Com uun Lat: Lon : J► E Address of Well Sitar s (ow wYruran an.e. Wreba..rvlaN,.N Lt. 81k. Sub. Name 4. USE: ,bomestic ❑ Municipal ❑ Monitor ❑ Irrigation ❑Thermal ❑ Injection ❑Other 5. TYPE OF WORK check all that apply e a etc ) ❑ New Well ❑ Modify ❑ Abandonment Other 6. DRILL METHOD: AAir Rotary ❑ Cade ❑ Mud Rotary ❑ Other 7. SEALING PROCEDURES Sed Matwial From To Wel lvd—e S.W Placenera Mound Was drive shoe used? ❑ N Shoe Depths} Was drive shoe seal tested? ❑Y /10 N How? 6. CASINGILINER: Wmeler Ro joagej Malarial Cadrg War W.el�ded Throeded ❑ p+ ❑ ❑ ❑ ❑ G ❑ ❑ ❑ ❑ Length of Headpipe /0' Le tlt o%tpi Packer I yCIN Type /mit row✓ 9. PERFORATIONSISCREENS PACKERTYPE Perforation Method Screen Type 8 Method of Installation From To Sm Size Number D!amelw Materiel casing user ❑ ❑ ❑ ❑ 10. FILTER PACK Flier Material I Frain I To Wdght(Wume Placer ON Method 11. TATIC WATER LEVEL OR ARTESIAN PRESSURE: Lo It. below ground Artesian pressure to, Depth flow encountered ft. De cdhe access port or control de Aces: 12. WELL TESTS: ❑ Pump ❑ Bailer Well ID No. �jotj"/`9`i Inspected by Twp Rge Sec _ 1/4 114 1/4 Let: Long: )bNr ❑ Flowing Artesian Water Temp. " ` Bottom hot. J temp. Water ality test or Comments: .. Nf fila 7 Depth first Water Encounter�� 13. LITHOLOGIC LOG: (Describe repairs or abandonment) • Water rmm I To I Remarks: Lithology,Water Quality aTemperature Completed Depth ,���[) (Measurable) Date: Started Dla . � •Q\� Completed • 14. DRILLER% CERTIFICATION VWe certify that all minimum well construction standards were complied with at the time the rig ASGVId*Company N [/ Flrm No.Principal Dr . Dflte QSy and —� Driller or Operator II Date Operator I Date Principal Driller and Rig Operator Required. Operator I must have signature of Dfiller/Operator II, FORWARD WHITE COPY TO WATER RESOURCES Geotechnical Services / Soil Testing & Inspection Services Vel W bA M in SITE Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 CONSULTING, LLC DESIGN SECTION CALCULATIONS (ACHD R -Value Method) Project: GANDER CREEK File No.: 19010-B Meridian Idaho Calc By: B. Arnold Client: Trilogy Development Date: 02/28/19 Design Thickness Equation: T = 0.0032 (TI) (100-R)(12) = GE (inches) T= Design Thickness TI = Traffic Index = 6 by ACHD GE = Gravel Equivalent R = R -Value = 12 by R -Value GE= 20.8 Inches ACHD ACP, 3/4" Road Base and Aggregate Subbase Actual Thickness Equivalent Thickness ACHD Asphalt Concrete Thickness = 2.5 Inches ACE= 5.0 Inches 3/4" Road Base Thickness Desired = 4.0 Inches RBE= 4.4 Inches Calculated Aggregate Subbase Thickness Equation: Subbase Thickness=SB=GE-ACE-RBE SB= 11.4 Inches CALCULATED DESIGN SECTION ACHD Asphaltic Concrete= 2.5 inches 3/4" Road Base = 4.0 inches Aggregate Subbase = 11.4 inches RECOMMENDED DESIGN SECTION Asphaltic Concrete = 2.5 inches 3/4" Road Base = 4.0 inches Aggregate Subbase = 12.0 inches W a, Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 DESIGN SECTION CALCULATIONS (ACHD R -Value Method) Project: GANDER CREEK File No.: 19010-B Meridian Idaho Calc By: B. Arnold Client: Trilogy Development Date: 02/28/19 Design Thickness Equation: T = 0.0032 (TI) (100-R)(12) = GE (inches) T= Design Thickness TI = Traffic Index = 8 By Agency GE = Gravel Equivalent R = R -Value = 12 By R -Value GE= 27.5 Inches ACHD ACP, 3/4" Road Base and Aggregate Subbase Actual Thickness Equivalent Thickness ACHD Asphalt Concrete Thickness = 3.0 Inches ACE= 7.5 Inches 3/4" Road Base Thickness Desired = 4.0 Inches RBE= 4.4 Inches Calculated Aggre-gate Subbase Thickness Equation: Subbase Thickness=SB=GE-ACE-RBE SB= 15.6 Inches CALCULATED DESIGN SECTION ACHD Asphaltic Concrete= 3.0 inches 3/4" Road Base = 4.0 inches Aggregate Subbase = 15.6 inches RECOMMENDED DESIGN SECTION Asphaltic Concrete = 3.0 inches 3/4" Road Base = 4.0 inches Aggregate Subbase = 14.0 inches Geotechnical Services / Soil Testing & Inspection Services SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 Pavement Engineering Inc. 0) 04 Cz Redding - San Luis Obispo 10 - Caltrans= / AMRL 7 QC • OA RESISTANCE (R) VALUE TEST ASTM D 2844 Laboratory No.: L190000 % 15.6 Project No.: 180096 (Site #18158) Sample Date: December 4. 2018 Report Date: January 1. 2019 Client: Site Consullino LLC Project Name: 2018 Laboratory Laboratory Testing Sample Description: Brown Silty Clay Sample Location: Gander Creek. TP -2 100 90 -- 80 70 -- — - -- - — 60 > - -- — — - — -- -- 50 8 c -- — 40 2 — 30 u) -- - - 20 -- -- — - 10 0 800 700 600 500 400 300 200 100 0 Exudation Pressure (P.S.I.) --+-Resistance Value Test —300 P.S.I. Specimen No. 1 2 3 Moisture Content %) 15.6 14.3 14.8 Dr Density PCF 116.1 119.1 118.9 Resistance Value R 6 19 12 Exudation Pressure PSI 174 466 311 Expansion Pressure 0 69 17 As Received Moisture Content RESISTANCE VALUE AT 300 P.S.I. 12 A-✓ A p►Q Reviewed By: Brandon Rodebaugh p HT. rin Materials Engineer Geotechnical Services /Soil Testing & Inspection Serv % 15.6 ices SITE CONSULTING, LLC Post Office Box 190537 - Boise, Idaho 83719 site.consulting.idaho@gmail.com - 208-440-6276 R -Value Reports Pavement EngineeHng Inc. 4 5 6 I�rJ Redding - San Luis Obispo 10.2 11.9 11.0 Ca1trans'7AA4RL 7 QC • QA 122.4 123.0 124A RESISTANCE (R) VALUE TEST 77 63 ASTM D 2844 Exudation Pressure (PSI) 5fi6 190 Laboratory No.: L182315 Expansion Pressure 0 0 Project No.: 1800961Site #18158) As Reserved Moisture Content (% 49 Sample Date: December 7, 2018 Report Date: December 31, 2018 Client: Site Consulting LLC Project Name: 2018 Laboratory, Testing Sample Description: Brawn Sand (Decomposed Granite) Sample Location: Gander Creek, TP -16 100 – — — 90 80 a� – -- — — 70 2 --- – — — -- — 60 > — — 50 c – — 40 @ -- – — 30 20 — 10 0 800 700 600 500 400 300 200 100 0 Exudation Pressure (P.S.I.) Resistance Value Test —300 P.S.I. RESISTANCE VALUE AT 300 P.S.I. 71 ✓ A aQ Reviewed By Brandon Rodabaugh • T. nie Materials Engineer Specimen No. Geotechnical Services /Soil Testing & Inspection Serv 4 5 6 Moisture Content (%) 10.2 11.9 11.0 Ur Density PCF 122.4 123.0 124A Resistance Value R 77 63 73 Exudation Pressure (PSI) 5fi6 190 343 Expansion Pressure 0 0 0 As Reserved Moisture Content (% 49 M Cz a, ices