Loading...
HomeMy WebLinkAboutSite Plan & Conceptual Engineering PlanD D C C F G G E E H H 2 3 4 5 6 7 8 9 12 16 15 13 10 11 14 F P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L C C B B 1 2 3 4 5 6 8 7 9 A A D D PHASE 2 10 H 12'' SD 8'' W 8'' W 8'' W 8'' W 10'' W 10'' W W s s SD SD SD CO S S S SS SS SS 8'' SS 2'' W W W SD 2'' W CO CO S CO 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 8'' W 4'' W 31.19' of 6" @ 6.60% ACHD ACHD ACHD ACHD W W W W ss ss ss ss ss ss w w w w w w w w w w w w w w w ss w w ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss ss s s s s s pp s pp co w w w w w w w w w w w w w w w w w w w w w w w w w w w w w ss ss sd sd sd sd sd sd sd sd t t t t e e e e e e e e e e e e e e e e 72' 17' 108' 8' 8' 108' 8' 99' 10' 26' 19' 28' 8' 108' 72' 8' 72' 95' 7' 30.1' 25' 19' 19' 25' 19' 9' 19' 19' 19' 25' 29' 19' 19' 25' 19' 63' 8' 108' 8' 54' 6.5' 30' 8' 27' 99' 8' 54' 7' 99' 19' 34.9' 11.2' 18' 7' 22' 15.2' 6' 107.5' 30.1' 99' 8' 36' 9.5' 5' 36' 17.8' 54' 90' 27' 25' 19' 19' 9.8' 26' 7' 30' 12' 3' 12' 26' 26' 26' 16.2' 10' 26' 13' 29.6' 27.4' 36.2' 271.7' 112.4' 12' SD SD SD S D SD SD 14' 1.4' 30' 32.9' 5' 10' 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 12'' SD 12'' SD 12'' SD 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 12'' SD 12'' SD 12'' SD 12'' SD 12'' SD 8'' SD 8'' SD 15'' SD 15'' SD 15'' SD 15'' SD 12'' SD 15'' SD 12'' SD 12'' SD 12'' SD 12'' SD 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 10'' SD 8'' SD 40' CANOPY 108' 8' 15' 63' 8' 8' 54' 8' 11' 7' 10.9' 12.9' 9' 5' 5' 5' 5' 167.3' 52.2' 19' 19' 19' 5.8' 6.5' 9.6' 7' 7' 9' 6.7' 3'-1" 95 8" 3 3 8" 2 3 8" O.D. TUBING SURFACE FLANGE MOUNT GROUND LEVEL 5'-23 8" IN-GROUND ANCHOR MOUNT 8" 3" O:\!2016\PG-852-1601 Ten Mile Crossing\02 CAD\02 Sheet Files\MOB at TM Crossing Phase 2\ID-1433-1810_Mob at TM Crossing Phase 2 CZC.dwg - Layout1 - 7/18/2019 04:58pm, melissak 1 5 REVISIONS REV # DATE DRAWING INFO DATE DESIGNED DRAWN *SEE GENERAL NOTES SHEET WARNING 0 1 2 IF THIS BAR DOES NOT MEASURE 2" THEN DRAWING IS NOT TO SCALE PRELIMINARY NOT FOR CONSTRUCTION www.horrocks.com PAGE C PROJECT CHECKED D B A # 2 3 4 2775 W. Navigator Dr., Suite 210 Meridian, ID 83642 (208) 859-2520 ID-1433-1810 RS MDK 07/12/19 SITE PLAN MERIDIAN CZC MOB AT TM CROSSING PHASE 2 MERIDIAN, ID 1 OF 1 1 H O R R O C K S E N G I N E E R S N 0 40' 80' SCALE: 1" = 40' SITE INFORMATION TOTAL LOD AREA: 259,335 SF (5.953 AC) MOB BUILDING · TOTAL BUILDING FOOTPRINT: 30,000+/- SF · TOTAL BUILDING AREA (ALL FLOORS): 129,428 SF · MAXIMUM BUILDING HEIGHT: 62'-0" at Parapet ZONING REQUIREMENTS · ZONING: CITY C-G, GENERAL COMMERCIAL · BUILDING SETBACKS: - FRONT = 0' - REAR = 0' - SIDES = 0' · LANDSCAPE SETBACKS: - LOCAL = 10' - COLLECTOR = 20' - ARTERIAL = 25' - ENTRYWAY CORRIDOR = 35' - INTERSTATE = 50' PARKING INFORMATION · PARKING STALLS REQUIRED:180 · PARKING STALLS PROVIDED: 459 · *HANDICAP STALLS REQUIRED: 7 · **HANDICAP STALLS PROVIDED: 9 · BICYCLE PARKING STALLS REQUIRED: 7 · BICYCLE PARKING STALLS PROVIDED: 8 NOTES: * PER ADA REQUIREMENTS ** INCLUDES 2 VAN ACCESSIBLE STALLS NOTES 1. DIMENSIONS ARE TO FRONT FACE OF CURB FOR DRIVE ISLES. 2. RADII ARE 3.0' UNLESS OTHERWISE NOTED. ENGINEER HORROCKS ENGINEERS 2775 W. NAVIGATOR DR. SUITE 210 MERIDIAN, ID 83642 CONTACT: ROB SUNDERLAGE PE PHONE: 208-895-2520 FLEXIBLE (ASPHALT) PAVEMENT SECTION TABLE ASPHALTIC CONCRETE CRUSHED AGGREGATE BASE STRUCTURAL SUBBASE COMPACTED SUBGRADE ASPHALT: ASPHALT MIX DESIGN SHALL MEET ISPWC SECTION 810 CLASS III PLANT MIX AND MATERIALS SHALL BE PLACED IN ACCORDANCE WITH ISPWC STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION (1/2" MIX DESIGN) AGGREGATE BASE: MATERIAL TO COMPLY WITH ISPWC STANDARD FOR CRUSHED AGGREGATE BASE MATERIAL STRUTURAL SUBBASE: MATERIAL TO COMPLY WITH STRUCTURAL FILL SECTI0N OF GEOTECH REPORT. THE PLACED MATERIAL SHALL BE NO GREATER THAN 4". - A QUALIFIED GEOTECHNICAL ENGINEER OR ENGINEERING TECHNICIAN IS REQUIRED TO VERIFY SUBGRADE COMPETENCY AT THE TIME OF CONSTRUCTION. ALL EARTHWORK, FLEXIBLE AND RIDID PAVEMENT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SITE GEOTECHNICAL REPORT. 18.0" 4.0" 3.0" SEE PAVEMENT SUBGRADE PREPARATION SECTION HEAVY DUTY HD SEE PAVEMENT SUBGRADE PREPARATION SECTION LD 12.0" 4.0" 2.5" LIGHT DUTY TM CROSSING SUBDIVISION BOUNDARY BIKE RACK DETAIL HD WEIR = C2 INV. IN = B PROFILE VIEW 6" 0.2' BAFFLE = C1 10' (TYP.) CONCRETE LEGEND LIMIT OF DISTURBANCE (LOD) THIS AREA NOT INCLUDED IN THIS PROPOSED SITE CZC BUT IS SHOWN BECAUSE ACCESS AND UTILITY SERVICES TO THE PROPOSED SITE ARE INCLUDED IN THIS AREA (INCLUDING STORM TREATMENT.) A SEPARATE APPLICATION WILL BE MADE TO THE CITY FOR THE AREA. SEEPAGE BED SCHEDULE SEEPAGE BED FINISH GRADE (FG) TOP SYSTEM (T) LENGTH (L) WIDTH (W) DEPTH (D) BOTTOM ROCK (B) BOTTOM SAND (18" MIN.) (BS) GROUND WATER (SHGWE) INF RATE (IN HR) SOILS VOLUME REQUIRED (FT3 ) (100YR) VOLUME PROVIDED (FT3 ) 1 2771.00 2770.00 255.00 100.00 2.00 2768.00 2766.50 2765.00 8.00 POORLY GRADED GRAVEL W/SAND 50,610 51,000 FUTURE PEDESTRIAN PATH BY OTHERS LIMIT OF DISTURBANCE, TYP. SEE ARCHITECTURAL PLANS FOR TRASH ENCLOSURE. DUMPSTER PAD IN SCOPE OF PARKING CZC. PROPOSED CONCRETE SIDEWALK, TYP. HANDICAP SPACES, TYP. ADA RAMP, TYP. FIRE RISER ROOM APPROXIMATE FDC LOCATION WATER AND FIRE SERVICE TO BE SERVED THROUGH PHASE 1 S. VANGUARD WAY SEWER GREASE TRAP. PROPOSED BUILDING ACHD STORMDRAIN EASEMENT 8" SEWER SERVICE SERVING MOB PHASE 2 EX. SEWER MANHOLE TYP CONCRETE PAD FOR BIKE STALLS SEE LANDSCAPE ARCHITECT PLANS CONNECT IRRIGATION SYSTEM TO EXISTING PRESSURE IRRIGATION EX. FIRE HYDRANT SAND/OIL SEPARATOR STORM WATER INFILTRATION SYSTEM STORM DRAIN MANHOLE TYP. 10' PATHWAY BY OTHERS TREES TO BE RELOCATED OR REMOVED EX. FIRE HYDRANT SAND/OIL SEPARATOR STORM DRAIN INLET TYP. STORM DRAIN INLET TYP. NOT INCLUDED IN THIS PHASE DEVELOPER BVA DEVELOPMENT, LLC 2775 W. NAVIGATOR DR. SUITE 220 MERIDIAN, ID 83642 PHONE: 208-616-1050