Loading...
HomeMy WebLinkAboutPZ - Applicant's Response to Staff Report 2019-08-141 Charlene Way From:Wes Baker <wes@babcockdesign.com> Sent:Wednesday, August 14, 2019 4:45 PM To:Sonya Allen; Meridian City Clerk Cc:Rick Stewart Subject:RE: Elevate Franklin Storage - CUP H-2019-0076 Staff Report for 8/13 Commission Hearing Attachments:H-2019-0076_CUP report_response 2019-08-14.pdf Hi Sonya, Rick’s out of the office today, but asked that I forward you an updated response to the staff report for the proposed conditional use permit for Elevate Franklin Storage. The response to Public Works item B3 was revised to indicate that the tiling of the Kennedy lateral was not required. It is our understanding that the City Council waived this condition with the previous subdivision approvals. Please review and let us know if there are any questions. Thanks, WESLEY BAKER AIA, NCARB, LEED AP BD+C / principal wes@babcockdesign.com / 801.824.1385 Babcock Design www.babcockdesign.com From: Rick Stewart <Rick@babcockdesign.com> Sent: Wednesday, August 14, 2019 1:53 PM To: Wes Baker <wes@babcockdesign.com> Subject: Fw: Elevate Franklin Storage - CUP H-2019-0076 Staff Report for 8/13 Commission Hearing Thanks Wes RICK STEWART / ASSOCIATE AIA rick@babcockdesign.com / 208.424.7699 direct / 208.590.4255 mobile Babcock Design 208.424.7675 800 W Main Street Ste. 940 2 Boise, ID 83702 www.babcockdesign.com From: Sonya Allen < sallen@meridiancity.org > Sent: Friday, August 9, 2019 8:57 AM To: Adrienne Weatherly < aweatherly@meridiancity.org >; Charlene Way < cway@meridiancity.org >; Chris Johnson <cjohnson@meridiancity.org > Cc: Rick Stewart < Rick@babcockdesign.com >; Bill Parsons < bparsons@meridiancity.org > Subject: Elevate Franklin Storage - CUP H-2019-0076 Staff Report for 8/13 Commission Hearing Attached is the staff report for the proposed conditional use permit for Elevate Franklin Storage. This item is scheduled to be on the Commission agenda on August 13 th . The public hearing will be held at City Hall, 33 E. Broadway Avenue, beginning at 6:00 pm. Please call or e-mail with any questions. Rick - Please submit any written response you may have to the staff report to the City Clerk’s office (cityclerk@meridiancity.org ) and me as soon as possible. Thanks, Sonya Allen | Associate Planner City of Meridian | Community Development Dept. 33 E. Broadway Ave., Ste. 102, Meridian, Idaho 83642 Phone: 208-884-5533 | Fax: 208-489-0578 Built for Business, Designed for Living All e-mail messages sent to or received by City of Meridian e-mail accounts are subject to the Idaho law, in regards to both release and retention, and may be released upon request, unless exempt from disclosure by law. 14 August 2019 City of Meridian Planning and Zoning 33 E. Broadway Ave. Ste. 102 Meridian, ID 83642 Re: CUP Staff Report – 3755 W. Perugia St, Meridian, ID, Elevate Self Storage – Franklin This letter is in response to the staff report dated, 8/15/19. The following responses are regarding the comments listed under Section VIII. City /Agency Comments: VIII. CITY/AGENCY COMMENTS A. Planning Division 1. Future development of this site shall comply with the provisions in the Development Agreement associated with H-2019-0072 and the conditions contained herein. The Rezone Ordinance associated with H-2018-0109 shall be approved by City Council and the Development Agreement modification associated with H-2019-0072 shall be recorded prior to submittal of a Certificate of Zoning Compliance and Design Review application for this site. RESPONSE: Will Comply 2. The Developer/Owner shall comply with the specific use standards listed in UDC 11-4-3- 47, Residential Self-Service Storage Facility. The application submitted with the Certificate of Zoning Compliance and Design Review applications shall demonstrate compliance with these standards. RESPONSE: Will Comply 3. The site/landscape plan submitted with the Certificate of Zoning Compliance application shall be revised as follows: To preserve public safety, a fence shall be installed along the Kennedy Lateral to prohibit access to the waterway in accord with the standards listed in UDC 11-3A- 6C.3. Six-foot tall wrought iron fencing should be constructed on the site along the Kennedy Lateral in accord with the standards listed in UDC 11-3A-6 and 11-3A-7 consistent with that installed to the north in the associated multi-family development. RESPONSE: The project building perimeter wall will act as boundary to the Kennedy Lateral. A wrought iron fence will be installed at the parking area for public safety from the Kennedy lateral. a. Depict trees within the street buffers as set forth in UDC 11-3B-7C. A minimum density of one (1) tree per 35 linear feet of buffer is required along with shrubs, lawn or other vegetative groundcover; trees must be located within the required buffer as opposed to outside of the buffer. RESPONSE: Will Comply b. In the Site Information table on Sheet AS101, update the required street buffer width along W. Perugia St. and N. Umbria Hills Ave. to 20 feet. RESPONSE: Will Comply 4. The hours of operation for the storage facility shall be limited to 6:00 am to 10:00 pm in accord with UDC 11-4-3-47. RESPONSE: Will Comply 5. On-site management or contact information for on-call management shall be provided for the storage facility as set forth in UDC 11-4-3-47. RESPONSE: Will Comply 6. Submit a security plan for the proposed facility with the Certificate of Zoning Compliance application as set forth in UDC 11-4-3-47. RESPONSE: Will Comply 7. All future structures shall comply with the design standards listed UDC 11-3A-19 and 11-4-3-47L, the Architectural Standards Manual including the Traditional Neighborhood District (TND) design standards, and the design elements noted in the Ten Mile Interchange Specific Area Plan. Note: The ASM prohibits pre- fabricated steel panels as field materials for building facades except when used with a minimum of two other qualifying field materials and meeting all other standard fenestration and material requirements (see 5.1I). RESPONSE: Will Comply 8. A Certificate of Zoning Compliance and Design Review applications are required to be submitted to the Planning Division and approved prior to submittal of building permit applications. RESPONSE: Will Comply B. Public Works Department 1. Applicant shall coordinate water and sewer main size and routing with the Public Works Department and execute standard forms of easements for any mains that are required to provide service outside of a public right-of-way. Minimum cover over sewer mains is three feet, if cover from top of pipe to sub- grade is less than three feet than alternate materials shall be used in conformance of City of Meridian Public Works Departments Standard Specifications. RESPONSE: Will Comply 2. The applicant shall provide easement(s) for all public water/sewer mains outside of public right of way (include all water services and hydrants). The easement widths shall be 20-feet wide for a single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat, but rather dedicated outside the plat process using the City of Meridian’s standard forms. The easement shall be graphically depicted on the plat for reference purposes. Submit an executed easement (on the form available from Public Works), a legal description prepared by an Idaho Licensed Professional Land Surveyor, which must include the area of the easement (marked EXHIBIT A) and an 8 1/2” x 11” map with bearings and distances (marked EXHIBIT B) for review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO NOT RECORD. Add a note to the plat referencing this document. All easements must be submitted, reviewed, and approved prior to development plan approval. RESPONSE: Will Comply 3. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting, crossing or laying adjacent and contiguous to the area being developed shall be tiled per UDC 11-3A-6. In performing such work, the applicant shall comply with Idaho Code 42-1207 and any other applicable law or regulation. RESPONSE: The City Council waived the condition requiring tiling of the Kennedy Lateral with the previous subdivision approvals. The project should be exempt from tiling the lateral. 4. Any existing domestic well system within this project shall be removed from domestic service per City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Engineering Department at (208)898-5500 for inspections of disconnection of services. Wells may be used for non-domestic purposes such as landscape irrigation if approved by Idaho Department of Water Resources Contact Robert B. Whitney at (208)334-2190. RESPONSE: Will Comply 5. Any existing septic systems within this project shall be removed from service per City Ordinance Section 9-1-4 and 9 4 8. Contact Central District Health for abandonment procedures and inspections (208)375-5211. RESPONSE: Will Comply 6. Street signs are to be in place, water system shall be approved and activated, and at a minimum, a compacted gravel road base shall be in place prior to applying for building permits. RESPONSE: Will Comply 7. All improvements related to public life, safety and health shall be completed prior to occupancy of the structures. RESPONSE: Will Comply 8. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to the issuance of a plan approval letter. RESPONSE: Will Comply 9. It shall be the responsibility of the applicant to ensure that all development features comply with the Americans with Disabilities Act and the Fair Housing Act. RESPONSE: Will Comply 10. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. RESPONSE: Will Comply 11. Developer shall coordinate mailbox locations with the Meridian Post Office. RESPONSE: Will Comply 12. All grading of the site shall be performed in conformance with MCC 11-12-3H. RESPONSE: Will Comply 13. Compaction test results shall be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. RESPONSE: Will Comply 14. The applicants design engineer shall be responsible for inspection of all irrigation and/or drainage facility within this project that do not fall under the jurisdiction of an irrigation district or ACHD. The design engineer shall provide certification that the facilities have been installed in accordance with the approved design plans. This certification will be required before a certificate of occupancy is issued for any structures within the project. RESPONSE: Will Comply 15. At the completion of the project, the applicant shall be responsible to submit record drawings per the City of Meridian AutoCAD standards. These record drawings must be received and approved prior to the issuance of a certification of occupancy for any structures within the project. RESPONSE: Will Comply 16. The City of Meridian requires that the owner post to the City a warranty surety in the amount of 20% of the total construction cost for all completed sewer, water and reuse infrastructure for duration of two years. This surety will be verified by a line item cost estimate provided by the owner to the City. The surety can be posted in the form of an irrevocable letter of credit, cash deposit or bond. Applicant must file an application for surety, which can be found on the Community Development Department website. Please contact Land Development Service for more information at 887-2211. RESPONSE: Will Comply Thank you for your time and attention to this matter. Regards, Rick Stewart Project Leader Babcock Design