Loading...
HomeMy WebLinkAboutChatsworth Subdivision FP-05-013 BEFORE THE MERIDIAN CITY COUNCIL C/C March 8, 2005 IN THE MATTER OF THE APPLICATION OF DYVER DEVELOPMENT, LLC FOR FINAL PLAT APPROVAL OF 77 SINGLE- FAMILY RESIDENTIAL BUILDING LOTS AND 4 COMMON LOTS IN AN R-8 ZONE LOCATED ON SOUTH LOCUST GROVE ROAD AND SOUTH OF VICTORY ROAD IN A PORTION OF THE S Yz OF THE S Yz OF THE NE ';4 OFT. 3N., R. IE., SECTION 30 CASE NO. FP-05-013 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council for Final Plat approval pursuant to Meridian City Code § 12-3-7 on March 8, 2005, and the Council finding that the Administrative Review is complete from Sonya Allen, Assistant City Planner for the Planning and Zoning Department, and Bruce Freckleton, Development Services Manager for the Public Works Department, dated: Hearing Date: March 8, 2005, to the Mayor and Council, and the Council having considered the requirements of the preliminary plat the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Final Plat of "PLAT SHOWING CHATSWORTH SUBDIVISION LOCATED IN A PORTION OF THE S Yz OF THE S Yz OF THE NE \4 OF T. 3N., R. lE., SECTION 30, BOISE MERIDIAN, MERIDIAN, ADA COUNTY, IDAHO 2005, ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR CHATSWORTH SUBDMSION I (FP-O5-013) Pagelof4 HANDWRITTEN DATE: 01/07/05, SHEET 1 OF 5, BAILEY ENGINEERING, INC.", EAGLE, IDAHO, DYVER DEVELOPEMNT, LLC, MERIDIAN, IDAHO, Developer, is Conditionally Approved subject to those conditions of Staff comments as set forth in the Memorandum to the Mayor and City Council ITom Sonya Allen, Assistant City Planner for the Planning and Zoning Department and Bruce Freckleton, Development Services Manager for the Public Works Department, dated: Hearing Date: March 8, 2005, listing 23 SITE SPECIFIC REQUIREMENTSIFINAL PLAT and 9GENERAL REQUIREMENTS, a true and correct copy of which is attached hereto marked Exhibit "A", and consisting of 4 pages, and by this reference incorporated herein, and the additional requirements ITom the action of the Council taken at their March 8, 2005 meeting as follows, to-wit: 1.1 Adopt the action of the City Council taken at their March 8, 2005 meeting, and specifically pertaining to the Staff Report, under Conditions of Approval, number 9, such that it now read as follows: Conditions of ADDroval 9. A gate at the stub street, E. Pisa Street shall be installed the full width of across the street at approximately 12-14' width. 2. The final plat upon which there is contained the Certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 1. The Plat dimensions are approved by the City Engineer; and ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR CHATSWORTH SUBDIVISION 1 (FP-O5-013) Page 2 of 4 2. The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which maybe adversely affected by this decision may, within twenty-eight (28) days after the date of this decision and order, seek a judicial review as provided by Chapter 52, Title 67, Idaho Code. By action of the City Council at its regular meeting held on the 'bth day of mOJCh ,2005. By: -~ Tammy de W. Ma"". City 0 Mori<fum . Attest: ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR CHATS WORTH SUBDMSION 1 (FP-O5-013) Page 3 of 4 By:,~}..(l ~t\ ~ City Clerk's Office Dated: 4-1 \ -05 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR CHATSWORTH SUBDIVISION 1 (FP-O5-013) Page4of4 MAYOR Tammy de Weead C;::tC/;;dltrn PUBLIC WORKS BUILDING DEPARTMENT (208) 898-5500. Fax (208)898-9551 CITY COUNCIL MEMBERS Keith Bird Christine Donnell Shaun Wardle Charles M. Rountree PLANNING AND ZONING DEPARTMENT (208) 884-5533 . FAX 888-6854 STAFF REPORT: Hearing Date: March 8, 2005 To: Mayor and City Council Sonya Allen, Assistant City Planner J'" Bruce Freckleton, Development Services Manager:j(. From: Re: Chatsworth Subdivision Request for Final Plat approval of Seventy-seven (77) Single-family Residential Building Lots and Four (4) Common Lots on 19.4 Acres in an R-8 Zone by Dyver Development, LLC (File No. FP-O5-013). We have reviewed the above referenced submittals and offer the following comments as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, Dyver Development, LLC, has applied for Final Plat approval of 77 single-family residential building lots and 4 common lots on 19.4 acres of land for Chatsworth Subdivision. The zoning designation for the proposed subdivision is R-8 (Medium Density Residential). The proposed gross density of the subdivision is 3.97 dwelling units per acre. The proposed net density is 5.22 dwelling units per acre. Chatsworth Subdivision is located approximately Yz mile south of E. Victory Road on the west side of S. Locust Grove Road, in the NE \4 of Section 30, T.3N., R.lE. The submitted final plat substantially complies with the approved Preliminary Plat. The stub street to the west was required to be relocated centrally between E. Mona Lisa Dr. & E. Pisa St. per ACHD; staff has no objection to this change. Staff recommends approval of Chatsworth Subdivision with the comments and conditions stated in this report. SITE SPECIFIC COMMENTS 1 FINAL PLAT 1. Applicant is to meet all terms of the approved Annexation (AZ-04-018) and Preliminary Plat (PP-04-025) for this subdivision. FP-05-013 Exhibit "A" Chatsworth Sub FP.doc Mayor & City Council Hearing Date: March 8, 2005 Page 2 2. Fencing must be in compliance with MCC 12-4-10 and 12-13-15-9. 3. Revise or add the following notes on the face of the plat: p.,t Delete note, no longer required on plat. (11.) "...is prohibited 1rnless SfleÐifieally alle'::ed BY tlIe f.da Ce\ffity Highway Distriet ami City ef Meridian." (13.) Complete instrument number. 4. The landscape plan shall be revised as follows: a. Include details for the proposed fencing, including construction materials. b. Label the species of the proposed shrubs shown on the plan. c. Subdivision name has changed to Chatsworth Subdivision. 5. The applicant has indicated that Nampa Meridian Irrigation District will own and maintain the pressure irrigation system within this development. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the irrigable common areas prior to signature on the final plat by the Meridian City Engineer. 6. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the Meridian City Engineer prior to final plat signature. 7. Please submit a copy of the Ada County Street Name Committee's "Final" letter for the street names and lot & block numbering. Make all corrections necessary to comply. 8. Prior to signature on the final plat by the City Engineer, vacate the 30-ft. wide east-west easement that bisects the property. 9. A gate at the stub street, E. Pisa Street shall be installed the full width of the street. 10. Revise the plat to include the name of the stub street to the west. 11. Add the missing boundary dimensions on Lot 15, Block 1. 12. Prior to issuance of the 51 st building permit, a Fire Department approved secondary emergency access point to the site shall be provided. FP-O5-013 Exhibit "A" Chatsworth Sub FP.doc 18. 19. 20. 21. Mayor & City Council Hearing Date: March 8, 2005 Page 3 13. Parking on E. Mona Lisa Drive, where the street section is proposed at 33-feet (back of curb to back of curb) shall be limited to one side. Paint the curb red and install "No Parking" signs on one side of the bulb-out (Lot I, Block 8) on E. Mona Lisa Drive. 14. Street signs are to be in place, Water system shall be approved and activated, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District and the Final Plat for this subdivision shall be recorded, prior to applying for building permits. 15. All development improvements, including sewer, fencing, micro-paths, pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy. 16. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, amenities, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 17. Sanitary sewer and water service to this site shall be via existing mains. The applicant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, as well as License Agreements with the appropriate jurisdiction for any mains that are required to provide service. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. Please submit all updated groundwaterlsoils monitoring data to the Public Works Department for review. Any drainage areas (detention/retention basins) must be designed to ensure that water is retained only during 100-year storm events, and for a period of time not to exceed 24 hours. Side slopes within drainage areas shall not exceed 3:1. Any portion of a drainage area not improved with sod/grass seed (or other approved landscaping) shall not count towards the required open space area. The project engineer should pay close attention to the results of field studies determining the groundwater, soil type & and characteristics during the design and construction phases. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established normal groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least I-foot above. Graphically depict an 8-foot wide public utilities, drainage and irrigation easement along the west side of Lot 7, Block 3, Lot 6, Block 1, Lot 3, Block 7, Lot 14, Block 1, Lot 4, Block 7, and the east side of Lot 13, Block 1. The extra width is required due to the location of an irrigation main. Dimension the widths of the public right-of-ways. FP-O5-013 Exhibit "A" Chatsworth Sub FP.doc Mayor & City Council Hearing Date: March 8, 2005 Page 4 22. Please indicate the centerlinelradius point on the final plat for the "knuckle" just east of S. Locust Grove Road. 23. Staffs failure to cite specific ordinance provisions, or terms of the approved Annexation or Preliminary Plat does not relieve the Applicant of responsibility for compliance. GENERAL REOUIREMENTS 1. Any tree over 4" in caliper that is removed ITom the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. 2. Any existing domestic wells and/or septic systems within this project will have to be removed ITom their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. Two-hundred-fifty and 1O0-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections andlor fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and permit ITom the Public Works Department prior commencing installations. 4. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 5. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 6. Applicant shall be responsible for application and compliance with any Section 404 Permitting that may be required by the Army Corps of Engineers. 7. Applicant shall be responsible for application and compliance with and NPDES Permitting that may be required by the Environmental Protection Agency. 8. Coordinate fire hydrant placement with the City of Meridian Public Works Department. 9. Developer shall coordinate mailbox locations with the Meridian Post Office. STAFF RECOMMENDATION Staff recommends approval of the final plat with the above stated comments and conditions. FP-O5-013 Exhibit "A" Chatsworth Sub FP.doc