Loading...
HomeMy WebLinkAboutStaff Comments MAYOR Tammy de Weerd olfe;;dltrH IDAHO PUBLIC WORKS BUILDING DEPARTMENT (208) 898-5500. Fax (208)898-9551 PLANNING AND ZONING DEPARTMENT (208) 884-5533 . FAX 888-6854 CITY COUNCIL MEMBERS Keith Bird Christine Donnell Shaun Wardle Charles M. Rountree STAFF REPORT: Hearing Date: March 29, 2005 To: Mayor, City Council and Planning & Zoning Commission RECEIVED From: Sonya Allen, Assistant City Planner ðA. Michael Cole, Development Services Coordinator M G MAR 2 4 2005 Re: Arcadia Subdivision City Of Meridian City Clerk Office Final Plat approval of Thirty-three (33) Single-Family Residential Building Lots and Three (3) Common Lots on 10.07 Acres in an R-8 Zone, by Pinnacle Engineers, Inc. (File No. FP-O4-084). We have reviewed the above referenced submittals and offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, Pinnacle Engineers, Inc., has applied for Final Plat approval of 33 single-family residential building lots and 3 common lots on 10.07 acres of land for Arcadia Subdivision. The current zoning designation for the proposed subdivision is R-8 (Medium Density Residential). This subdivision will have a gross density of3.28 d.u./acre and a net density of 4.95 d.u./acre. Arcadia Subdivision is located approximately \4 mile south of Chin den Blvd. and Y2 mile west of N. Locust Grove Rd. in the NE \4 of Section 30, TAN., R.lE. The common area lots within this subdivision consist oflandscaping and open space and will be owned and maintained by the Homeowners Association. The pressurized irrigation system within this development will be owned and maintained by Settler's Irrigation District. The submitted final plat substantially complies with the approved preliminary plat for this subdivision. Staff recommends approval of the [mal plat for Arcadia Subdivision with the comments and conditions stated in this report. FP-O4-084 Arcadia Sub FP.doc 9. Mayor & City Council Hearing Date: March 29, 2005 Page 2 SITE SPECIFIC COMMENTS I FINAL PLAT 1. Applicant is to meet all tenDs of the approved annexation (AZ-O4-021) and preliminary plat (PP-04-021). 2. The applicant has indicated that the Settler's Irrigation District will own and maintain the pressure irrigation system within this development. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the municipal water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Fencing must be in compliance with MCC 12-4-10 and MCC 12-13-15-9. No sight obscuring fencing shall be placed near the micropath or the open space area per Preliminary Plat Finding #C.2.b., pg. 3. 4. Street signs are to be in place, water system shall be approved and activated, fencing installed, drainage lots constructed, road base approved by the Ada County Highway District and the Final Plat for this subdivision shall be recorded, prior to applying for building pennits. 5. All development improvements, including sewer, fencing, micro-paths, pressurized irrigation and landscaping shall be installed and approved prior to obtaining certificates of occupancy. 6. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, amenities, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 7. Sanitary sewer service and municipal water to this site shall be via extensions ITom existing mains. Applicant shall provide a second water main feed for this project ITom an adjacent development. Said second feed shall contain a pressure reducing valve to separate this development fonD an adjacent pressure zone. Applicant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard fOnDS of easements, for any mains that are required to provide service. 8. Complete the Certificate of Owners and accompanying Acknowledgment prior to signature on the final plat. Basis of Bearing on Plat does not match Basis of Bearing in Certificate of Owners please correct so they match. FP-O4-084 Arcadia Sub FP.doc Mayor & City Council Hearing Date: March 29,2005 Page 3 10. 11. 12. 13. 14. 15. 16. 11. 17. Revise year of platting in situate statement to reflect actual year of platting. Graphically depict an 8-foot wide public utilities, and drainage and irrigation easement along the east lot line of Lot 4, Block 1; and Lot 1, Block 3. The extra width is due to an irrigation main. Graphically depict a 13-foot wide public utilities, and drainage irriation easement along the rear lot lines of Lots 2-7, Block 1. The extra width is due to pressurized and gravity irrigation mains. Graphically depict a IS-foot wide public utilities, and drainage irrigation easement along the rear lot lines of Lots 1-6, Block 3; and the southern lot line of Lot 7, Block 2. The extra easement is required by Settlers irrigation. Lot 11, Block 3 does not meet minimum street ITontage (65 feet). Adjust lots to meet minimum requirements. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as detennined during the plan review process, prior to signature on the final plat per Resolution 02-374. Revise the landscape plan dated 6/15/04, prepared by Pinnacle Engineers, Inc., as follows: a. Include a fencing plan in compliance with MCC 12-4-10 and MCC 12-13-15-9. Fencing is required along the micropath in Lot 6, Block 4 and a 6-ft. solid material fence is required around the perimeter ofthe subdivision. b. One tree per 35 linear feet is required along the micropath on Lot 6, Block 4. c. A minimum 5-ft. wide paved pathway with 5-ft. of landscaping on each side is required within the micropath lot. d. Include the square footage of open space and number of trees required per MCC in the calculations table. e. Additional trees are required per MCC 12-13-13-6 Mitigation Trees. Either revise the landscape plan to show the remaining required trees or apply to the Planning Director for Alternative Compliance (MCC 12-13-18). Revise or add the following notes on the face of the plat dated 1/24/05, prepared by Pinnacle Engineers, Inc.: (3.) (4.) Stike the words "excepting right of ways" Add note to face of plat " A ten-foot wide public utilities, and drainage easement is hereby dedicated along all rear lot lines unless other wise dimensioned." Developer shall coordinate mailbox locations with the Meridian Post Office. 18. All development features shall comply with the Americans with Disabilities Act and the Fair Housing Act. FP-O4-084 Arcadia Sub FP.doc 4. 5. 6. Mayor & City Council Hearing Date: March 29, 2005 Page 4 19. Please submit all updated groundwater/soils monitoring data to the Public Works Department for review. Any drainage areas (detention/retention basins) must be designed to ensure that water is retained only during 100-year stonn events, and for a period of time not to exceed 24 hours. Side slopes within drainage areas shall not exceed 3: 1. Any portion of a drainage area not improved with sod/grass seed (or other approved landscaping) shall not count towards the required open space area. The project engineer should pay close attention to the results of field studies detennining the groundwater, soil type & and characteristics during the design and construction phases. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established nonnal groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least I-foot above. 20. Staff's failure to cite specific ordinance provisions or tenDS of the approved annexation or preliminary plat does not relieve the Applicant of responsibility for compliance. GENERAL REOUIREMENTS 1. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the meridian City Engineer prior to final plat signature 2. Any existing domestic wells and/or septic systems within this project will have to be removed ITom their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. One hundred watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are detennined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and pennit ITom the Public Works Department prior commencing installations. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. Coordinate fire hydrant placement with the City of Meridian's Public Works Department. Any tree over 4" in caliper that is removed ITom the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. FP-04-084 Arcadia Sub FP.doc Mayor & City Council Hearing Date: March 29, 2005 Page 5 7. Applicant shall be responsible for application and compliance with any Section 404 Pennitting that may be required by the Army Corps of Engineers. 8. Applicant shall be responsible for application and compliance with and NPDES Pennitting that may be required by the Environmental Protection Agency. STAFF RECOMMENDATION Staff recommends approval of the final plat for Arcadia Subdivision with the above stated comments and conditions. FP-O4-084 Arcadia Sub FP.doc