Loading...
HomeMy WebLinkAboutHacienda Subdivision CUP R.ECEIVED FEB 11 2005 offe;;di~\ ,=....'.'.'.\.I'~"J. ." ,. ,:~i City Of Meridian City Clerk Office STAFF SUMMARY OF PLANNING AND ZONING COMMISSION RECOMMENDA nON TO CITY COUNCIL P & Z Commission Date of Recommendation: January 20,2005 Project Name: Hacienda Subdivision Case No(s): AZ-04-034, PP-04-043, CUP-04-052 Applicant: Doug Jayo A. Recommendation: Approve with conditions (all ayes - all applications) B. Summary of Public Hearing: 1. In favor: Shawn Nickel, Land Consultants, Inc. (Applicant's Representative), David Bailey (project engineer - discussed street sections, irrigation and piping of lateral) 2. In opposition: None 3. Commenting: Doug Beehler (fencing along east boundary), Cameron Jayo (stated 6' vinyl fence on east and south boundaries), Bruce Freckleton 4. Staff presenting application: Brad Hawkins-Clark C. Key Issues of Discussion by Commission: 1. Block, decorative fence around existing residence - setback and safety issues 2. Access and visibility to common area 3. Perimeter fencing (location and type) D. Key Commission Changes to Staff Recommendation: I. Added a new site specific condition to require a perimeter fence 2. Relocate Rio Vista Dr. to provide for a minimum lO-foot setback ITom right-of-way for the existing fence on Lot 1, Block 5 E. Outstanding Issue(s) for City Council: 1. At the time of the P&Z Commission hearing, Settlers Irrigation District had not made a final decision on whether the North Slough Lateral must be piped or not. The applicant's original plat proposed leaving it open as an amenity and the P&Z Commission supported this proposal. Preliminary Plat Condition #4 required the applicant to submit a written request to City Council to waive the tiling requirement of Meridian City Code. To date, no such request has been submitted. The City Council should have the applicant provide an update on this and amend Site Specific Condition #4 as necessary. 2. On Friday, 2/1 1/05, staff was infonned that the applicant intends to remove one buildable lot ITom the east boundary and remove the common lots on the south boundary (that separate the townhouse structures). Staff has not reviewed the new layout and we recommend this issue be addressed at the 2/15/05 City Council hearing. F. Preliminary Plat/CUP Site Plan I. Date of Preliminary Plat reviewed by Commission: January 6,2005 2. Date of Revised Preliminary Plat: January 25,2005 (submitted 2/3/05) 3. Date of CUP Site Plan reviewed by Commission: November 10,2004 4. Date of Landscape Plan reviewed by Commission: November 3,2004 G. Recommended Conditions of Approval (as amended by Commission, if applicable) Exhibit A - Annexation & Zoning Exhibit B - Preliminary Plat Exhibit C - Conditional Use Pennit EXHIBIT A Annexation and Zoning Application Hacienda Subdivision AZ-04-034 ANNEXATION AND ZONING COMMENTS 1. The legal description submitted with the application (stamped by Clinton W. Hansen on 11- 08-04) appears to meet the requirements of the City of Meridian and State Tax Commission and places the parcel contiguous to existing city limits. 2. Any existing domestic wells and/or septic systems within this project will have to be removed ITom their domestic service, per City Ordinance Section 5-7-517, when services are available from the City of Meridian. Wells may be used for non-domestic purposes such as landscape irrigation. 3. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the parcel shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the Meridian City Engineer prior to final plat signature. 4. Any future subdivision, planned development, uses and construction shall comply with the City of Meridian ordinances in effect at the time. 3. EXHIBIT B Preliminary Plat Hacienda Subdivision (File PP-O4-043) [P&z Commission modifications are shown in ~ and underline format.} SITE SPECIFIC CONDITIONS-PRELIMINARY PLAT 1. Sanitary sewer service to this site shall be via main line extensions fì'om the North Slough Trunk that is currently in the design stage by the City of Meridian. The applicant will be responsible for constructing the lateral sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. The subdivision designer is responsible for coordinating main sizing and routing with the Public Works Department. This development shall be subject to latecomer fees, to reimburse those responsible for bringing sanitary sewer service to the area, when and if the Latecomers Fee Agreement is established. Latecomer's fees shall be due and payable prior to signature on the final plat for each phase. This proposed development is currently not serviceable by the City of Meridian's sanitary sewer system. Proceeding through the approval process is strictly the risk of the applicant. The City of Meridian does not guarantee sewer service within the development time frames outlined in Meridian City Ordinance. 2. Water service to this site shall be via a 16-inch main line extension from a main currently being designed by the City of Meridian. The City's project will extend water service up N. Meridian Road to McMillan. The applicant will be responsible for constructing the 16-inch diameter water mains to the mid-section line, and a 12-inch main to the north boundary line extended in Meridian Road. All other mains through this proposed development shall be 8-inch diameter. The subdivision designer is responsible for coordinating main sizing and routing with the Public Works Department. This development shall be subject to latecomer fees, to reimburse those responsible for bringing water service to the area, when and if the Latecomers Fee Agreement is established. Latecomer's fees shall be due and payable prior to signature on the final plat for each phase. The applicant has not indicated who will own and maintain the pressurized irrigation system within this development. If the system remains private, plans and specifications shall be reviewed by the Public Works Department as part of the development plan review process. A draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval, and the applicant shall be subject to irrigation plan review fees. Underground vear-round pressurized irrigation must be provided to all lots within this development. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. Applicant shall be required to utilize any existing surface or well water for the primary source. If a sUlface or well source is not available, a single-point connection to the culinary water system shall be Hacienda Subdivision - PP-O4-043 - Exhibit B Pagelof6 required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 4. Prior to the City Council public hearing on this application, the applicant shall submit a written request to waive MCC 12-4-13 to not pipe the North Slough Lateral. If the request is approved, for all unpiped (open) sections of the North Slough Lateral, slopes shall not be steeper than 4: I. A "typical" detail of the cross-section of these sections shall be submitted to the P&Z Department with the final plat landscape plan. The P&Z Commission supports the applicant's intention to not pipe the North Slough Lateral. 5. Prior to City Council approval of the final plat, the applicant shall submit a written statement ITom Settlers Irrigation District (SID) to the P&Z Department clarifying the required easement width for the North Slough drain. Applicant shall meet the conditions of SID. 6. The af)plie!lflt sflsalà eS!!HlliI the !seatis!! sf !fie gra,..ity iFfigatio!! ¡¡lIe eHffe!!tly shswl'I in Lot 13, Block á and, if a reloeatiol'l is l'Ieeessar)', refleet the eSffeet loeatisl'l Of] the rtJvised Prelill'lil'lary Plat. (Note: The project engineer clarified this issue at the P&Z Commission hearing.) 7. Revise the Preliminary Plat to show Rio Colinas Street as a 36-foot street section. 8. Revise the Preliminary Plat to graphically depict common driveways for the townhouse lots in Blocks 6 and 7. 9. The conceptual landscape plan submitted with the preliminary plat (Sheets PPL-C and PPL-1, dated 11103/04 by The Land Group) is approved with the following changes: a. Revise Sheet PPL-I to show the landscape island in Rio Colinas. b. Revise Sheet PPL-1 to remove the fence currently shown encroaching on Lot 18, Block 4. c. No trees will be allowed within sanitary sewer or irrigation easements, except as approved through a separate License Agreement. Relocate any trees show within easements to other locations within the development. 10. Unless otherwise waived by the City Council, all irrigation ditches, laterals or canals intersecting, crossing or lying adjacent and contiguous to the parcel shall be tiled per MCC 12-4-13. Plans will need to be approved by Settlers Irrigation District, or lateral users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If lateral users association approval can't be obtained, plans will be reviewed and approved by the Meridian City Engineer prior to final plat signature. Meridian City Code 12-4-l3-B requires that tiled ditches have a sloped bar-grated inlet structure and access/cleanout boxes at a maximmn of four hundred foot (400') spacing and at all angle points of the pipeline. The applicant shall address the access to each of Hacienda Subdivision - PP-O4-043 - Exhibit B Page 2 of 6 4. 5. 6. 7. these required structures, as some will fall within the back yard of several lots. 11. Applicant shall construct a minimum 5-foot wide, detached sidewalk along the entire subdivision ITontage of Meridian Road and adjacent to the designated collector roadways. Coordinate sidewalk location with ACHD. 12. All areas being counted toward the 10% open space amenity shall be free of "wet ponds" or other such nuisances. All stonnwater detention facilities incorporated into the required open space are subject to MCC 12-13-14 and shall be fully vegetated with grass and trees, as depicted on the submitted landscape plans. Any ACHD-required access driveways to serve stonnwater areas that are located within required open space lots shall be shown on the detailed landscape plans with each final plat. 13. Applicant shall construct 6-foot high. vinvl. perimeter fencing, unless otherwise approved bv the Zoning Administrator. STANDARD PRELIMINARY PLAT CONDITIONS 1. Please submit a copy of the Ada County Street Name Committee's approval letter for the subdivision name, and the lot and block numbering. Make any corrections necessary to confonn. 2. Coordinate fire hydrant placement with the City of Meridian Public Works Department. 3. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, play equipment, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. All micropaths within the proposed subdivision shall be designed in accordance with MCC 12-13-15 "Micropath Landscaping". A detailed landscape plan, in compliance with the landscape ordinance shall be submitted for the subdivision with the final plat application, the landscape plan shall include the location and design of any proposed playground equipment. Sidewalks within the proposed subdivision shall be built in accordance with MCCI2-13- 10-8. 250 and 1O0-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are detennined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and pennit ITom the Public Works Department prior commencing installations. Hacienda Subdivision - PP-O4-043 - Exhibit B Page 3 of 6 11. 12. 13. 8. Please submit up to date groundwater/soils monitoring data to the Public Works Department for review. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate within a period of time not to exceed 24 hours for all stonns up to and including a 100-year stonn event. Side slopes within drainage areas shall not exceed 3: 1. 9. Any tree over 4" in caliper that is removed ITom tl1e property shall be replaced by installing additional trees, being the equivalent nmnber of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. 10. Developer shall coordinate mailbox locations with the Meridian Post Office. Any existing domestic wells and/or septic systems within this project will have to be removed ITom their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established nonnal groundwater elevation. FIRE DEPARTMENT CONDITIONS 1. The existing residence (future clubhouse) shall be brought up to "Assembly" occupancy and comply with the IFc. 2. No parking is allowed within any of the "knuckle" areas of the plat. 3. All roofing materials on the attached dwelling units shall be a non-combustible material. 4. One and two family dwellings will require a fire-flow of 1,000 gallons per minute available for duration of2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. International Fire Code Appendix D 5. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 6. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. a. Fire Hydrants shall have the 4 \6" outlet face the main street or parking lot aisle. b. The Fire hydrant shall not face a street which does not have addresses on it. c. Fire hydrant markers shall be provided per Public Works spec. d. Locations with fire hydrants shall have the curb painted red 10' to each side of the hydrant location. e. Fire Hydrants shall be placed on comers. Hacienda Subdivision - PP-O4-043 - Exhibit B Page 4 of6 f. Fire hydrants shall not have any vertical obstructions to outlets within 10'. 7. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have an approved turn around. 8. All entrance and internal roads shall have a turning radius of28' inside and 48' outside radius. 9. Insure that all yet undeveloped parcels are maintained ITee of combustible vegetation. 10. Operational fire hydrants and temporary or pennanent street signs are combustible construction begins. required before 11. To increase emergency access to the site a minimmn of two points of access will be required for any portion of the project, which serves more than 50 homes. The applicant shall provide a stub street to the property to the (west/east/north/south). The two entrances shall be separated byno less than Y, the diagonal measurement of the project. 12. Building setbacks shall be per the Building Code for one and two story construction. 13. The roadways shall be built to Ada County Highway Standards and shall have a clear driving surface, available at all times, which is 20' wide. Streets with less than a 29' street width shall have no parking. Streets with less than 33' shall have parking only on one side. 14. Maintain a separation of5' ITom the building to the dumpster enclosure. 15. All portions of the buildings located on this project must be within 150' of a paved surface as measured around the perimeter of the building. 16. All common driveways shall be straight or have a turning radius of 28' inside and 48' outside and shall have a clear driving surface which is 20' wide. POLICE DEPARTMENT CONDITIONS I. The pedestrian access to the proposed clubhouse/community entrance is not well-defined. The applicant shall submit a revised landscape plan that uses walkway paving materials and landscaping to alert motorists to the pedestrian traffic. 2. The proposed landscaping creates a hiding spot near and south of Lot 20, Block 5 and Lot 24, Block 5. The applicant shall submit a revised landscaping plan that affords greater visibility of the area from public areas such as a street or parking lot. 3. Any interior fencing shall allow visibility ITom the street or shall not exceed four feet in height if solid fencing is used (pertaining to Lot I, Block 5). Hacienda Subdivision - PP-O4-043 - Exhibit B Page 5 of 6 PARKS DEPARTMENT CONDITIONS 1. Standard for Mitigation of trees: The standard established in the City of Meridian Landscape Ordinance (MCC 12-13-13-6) will be followed. 2. Standard Plan for Protection of Existing Trees during Construction: The standard established in the City of Meridian Landscape Ordinance (MCC 12-13-13) will be followed. SANITARY SERVICES CO. CONDITIONS 1. Please contact Bill Gregory at SSC (888-3999) for detailed review of your proposal and submit stamped (approved) plans with your Certificate of Zoning Compliance application. Hacienda Subdivision - PP-O4-043 - Exhibit B Page 6 of 6 6. 7. EXHIBIT C Conditional Use Permit Hacienda Subdivision (File CUP-04-052) [P&Z Commission changes shown in ~ and underline format.} SITE SPECIFIC CONDITIONS (Conditional Use Permit) 1. Applicant shall meet all of the requirements of the preliminary plat as a condition of the Conditional Use Pennit. 2. Applicant shall submit details of the proposed bridge across the North Slough Lateral shown on Lot 20, Block 5 of the Landscape Plan with the final plat application. Said bridge shall comply with any applicable ADA design specifications. 3. A condition of the CUP/PD shall be that the applicant participates in any road inITastructure agreements in the North Meridian Planning Area negotiated with ACHD and shall faithfully perfonn the tenus of such agreement or agreements. 4. If !fie P&Z Ce!l'\FI'\iasiel'l sHfJperts an exee¡'Jtiol'l te MCC 12 1 10.C.3. (Fel'lee se!fiaek3), the applieant shall sIHH'I'Iit a re'iÎseà CUP/PD applieatiel'l prior Ie the City CoHl'lcil hearing that re'¥lests said e¡l6e¡'Jtiol'l. A minimum lO-foot setback ITom the Rio Vista Drive right- of-wav is required for the existing wall on Lot L Block 5. 5. All development shall comply with the Americans with Disabilities Act and the Fair Housing Act, including the community clubhouse. The applicant shall provide/construct the following amenities within the subdivision: a. Over 10% of the gross area as open space; and b. A community clubhouse with restrooms and a swimming pool. The following deviations ITom the Zoning and Subdivision Ordinance (MCC Title 11 and 12) are approved as part ofthis application: Min. Lot Size- Citv Requirement (R-8) 6,500 sq. ft. per lot Proposed Lot Size 2,850 sq. ft. per lot (attached units only) Lot Frontage- Citv Requirement 65' minimum Proposed Minimum Frontage 30' minimum Hacienda Subdivision - CUP-O4-052 - Exhibit C Page 1 of2 Zero Lot Lines- Citv ReQuirement 1 perrot (max.) Proposed Standard 2 per lot 8. All areas being counted toward the 10% open space amenity shall be free of "wet ponds" or other such nuisances. All stonnwater detention facilities incorporated into the required open space are subject to MCC 12-13-14 and shall be fully vegetated with grass and trees, as depicted on the submitted landscape plans. 9. A Certificate of Zoning Compliance must be obtained for the clubhouse and swimming pool prior to applying for building pennits. 10. Townhouse Elevations: A varied color and/or building material scheme is reQuired for the townhome structures within the subdivision. Applicant shall obtain written approval ITom the P&Z Department for said scheme prior to Citv Engineer signature of the final plat. Hacienda Subdivision - CUP-O4-052 - Exhibit C Page 2 of2