November 1, 2004
TO:
Meridian Planning & Zoning Commission
FROM:
Joseph Silva, Deputy Chief, Fire Prevention
SUBJECT:
Ashford Greens Subdivision File FP -04-059
RECEIVED
Nav 0 1 2004
City Of Meridian
City Clerk Office
The following will be the requirements and/or concems to provide minimum levels of fire
protection for the proposed project:
1. One and two family dwellings will require a fire-flow of 1,000 gallons per minute
available for duration of 2 hours to service the entire project. Fire hydrants shall be
placed an average of 400' apart. Intemational Fire Code Appendix D
2. Acceptance of the water supply for fire protection will be by the Meridian
Water Department.
3. Final Approval of the fire hydrant locations shall be by the Meridian Fire
Department.
a. Fire Hydrants shall have the 4 y,:' outlet face the main street or parking lot
aisle.
b. The Fire hydrant shall not face a street which does not have addresses on
it.
c. Fire hydrant markers shall be provided per Public Works spec.
d. Locations with fire hydrants shall have the curb painted red 10' to each
side of the hydrant location.
e. Fire Hydrants shall be placed on comers.
f. Fire hydrants shall not have any vertical obstructions to outlets within 10'.
4. The phasing plan may require that any roadway greater than 150' in length
that is not provided with an outlet shall be required to have an turn-around.
5. All entrance and internal roads shall have a turning radius of 28' inside radius and
48'outside radius.
6. Operational fire hydrants and temporary or permanent street signs are required
before combustible construction begins.
7. All portions of the buildings located on this project must be within 150' of a paved
surface as measured around the perimeter of the building.