HomeMy WebLinkAboutPZ - ACHD ReportPaul Woods, President
Rebecca W. Arnold, Vice President
Sara M. Baker, Commissioner
Jim D. Hansen, Commissioner
Kent Goldthorpe, Commissioner
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
June 8, 2017
To: Amanda Bidwell
neUdesign Architecture
725 E. 2nd St.
Meridian, ID 83642
Subject: MER17-0043 / H-2017-0072
143 W. Archerfield Street
Raisin’ Angels Daycare
In response to your request for comment, the Ada County Highway District has reviewed the
submitted application and site plan for the item referenced above. It has been determined
that ACHD has site specific conditions of approval for this application.
A. Findings of Fact
1. Driveways
a. Driveway Location Policy: District policy 7208.4.1 requires driveways located
near intersections to be located a minimum of 75-feet (measured centerline-to-
centerline) from the nearest street intersection.
Successive Driveways: District Policy 7208.4.1 states that successive
driveways away from an intersection shall have no minimum spacing
requirements for access points along a local street, but the District does
encourage shared access points where appropriate.
Driveway Width Policy: District policy 7208.4.3 restricts commercial driveways
to a maximum width of 40-feet. Most commercial driveways will be constructed as
curb-cut type facilities.
Driveway Paving Policy: Graveled driveways abutting public streets create
maintenance problems due to gravel being tracked onto the roadway. In
accordance with District policy, 7208.4.3, the applicant should be required to pave
the driveway its full width and at least 30-feet into the site beyond the edge of
pavement of the roadway
b. Applicant’s Proposal: The applicant is proposing to construct a 26-foot wide
curb return type driveway, located 173-feet west of Dyver Avenue (measured
centerline-to-centerline).
c. Staff Comments/Recommendations: The applicant’s proposal meets District
policy and should be approved as proposed.
The applicant should be required to pave the driveway its full width and a
minimum of 30-feet into the site beyond the edge of Archerfield Street.
2. Comment to the City of Meridian
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
a. Cross Access Easements/Shared Access Policy: District Policy 7202.4.1
states that cross access utilizes a single vehicular connection that serves two or
more adjoining lots or parcels so that the driver does not need to re-enter the
public street system.
b. Staff Comments/Recommendations: ACHD staff recommends the City of
Meridian require a cross access easement be provided to 191 W. Archerfield
Street (Lot 04, Block 02 of the Paramount Square Subdivision). Cross access in
this location would reduce the need for a driveway at the intersection of Elsinore
Avenue and Archerfield Street.
B. Site Specific Conditions of Approval
1. Construct a 26-foot wide curb return type driveway, located 173-feet west of Dyver
Avenue (measured centerline-to-centerline).
2. Pave the driveway its full width and a minimum of 30-feet into the site beyond the edge of
Archerfield Street.
3. A Traffic Impact Fee will be assessed by ACHD and will be due prior to issuance of a
building permit. Please contact the ACHD Planner (see below) for information regarding
impact fees.
4. Plans shall be submitted to the ACHD Development Review Department for plans
acceptance, and impact fee assessment (if an assessment is applicable).
5. Comply with the Standard Conditions of Approval as noted below.
C. Traffic Information
Trip Generation
This development is estimated to generate 452 vehicle trips per day; and 76 vehicle trips per
hour in the PM peak hour, based on the Institute of Transportation Engineers Trip
Generation Manual, 9th edition.
Average Daily Traffic Count (VDT): Average daily traffic counts are based on ACHD’s most
current traffic counts
The average daily traffic count for Meridian Road south of Producer Drive was 8,434
on September 24, 2014.
The average daily traffic count for McMillan Road west of Meridian Road was 11,755
on October 27, 2015.
If you have any questions, please feel free to contact me at (208) 387-6335.
Sincerely,
Austin Miller
Planner I
Development Services
cc: City of Meridian, via e-mail
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
Vicinity Map
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
Site Plan
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
Standard Conditions of Approval
1. All proposed irrigation facilities shall be located outside of the ACHD right -of-way
(including all easements). Any existing irrigation facilities shall be relocated outside of
the ACHD right-of-way (including all easements).
2. Private Utilities including sewer or water systems are prohibited from being located
within the ACHD right-of-way.
3. In accordance with District policy, 7203.6, the applicant may be required to update any
existing non-compliant pedestrian improvements abutting the site to meet current
Americans with Disabilities Act (ADA) requirements. The applicant’s engineer should
provide documentation of ADA compliance to District Development Review staff for
review.
4. Replace any existing damaged curb, gutter and sidewalk and any that may be damaged
during the construction of the proposed development. Contact Construction Services at
387-6280 (with file number) for details.
5. A license agreement and compliance with the District’s Tree Planter policy is required
for all landscaping proposed within ACHD right-of-way or easement areas.
6. All utility relocation costs associated with improving street frontages abutting the site
shall be borne by the developer.
7. It is the responsibility of the applicant to verify all existing utilities within the right-of-way.
The applicant at no cost to ACHD shall repair existing utilities damaged by the
applicant. The applicant shall be required to call DIGLINE (1-811-342-1585) at least
two full business days prior to breaking ground within ACHD right-of-way. The applicant
shall contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits
(spare or filled) are compromised during any phase of construction.
8. Utility street cuts in pavement less than five years old are not allowed unless approved
in writing by the District. Contact the District’s Utility Coordinator at 387-6258 (with file
numbers) for details.
9. All design and construction shall be in accordance with the ACHD Policy Manual,
ISPWC Standards and approved supplements, Construction Services procedures and
all applicable ACHD Standards unless specifically waived herein. An engineer
registered in the State of Idaho shall prepare and certify all improvement plans.
10. Construction, use and property development shall be in conformance with all applicable
requirements of ACHD prior to District approval for occupancy.
11. No change in the terms and conditions of this approval shall be valid unless they are in
writing and signed by the applicant or the applicant’s authorized representative and an
authorized representative of ACHD. The burden shall be upon the applicant to obtain
written confirmation of any change from ACHD.
12. If the site plan or use should change in the future, ACHD Planning Review will review
the site plan and may require additional improvements to the transportation system at
that time. Any change in the planned use of the property which is the subject of this
application, shall require the applicant to comply with ACHD Policy and Standard
Conditions of Approval in place at that time unless a waiver/variance of the
requirements or other legal relief is granted by the ACHD Commission.
_____________________________________________________________________________________________________________
Ada County Highway District • 3775 Adams Street • Garden City, ID • 83714 • PH 208-387-6100 • FX 345-7650 • www.achdidaho.org
Request for Appeal of Staff Decision
1. Appeal of Staff Decision: The Commission shall hear and decide appeals by an
applicant of the final decision made by the Development Services Manager when it is
alleged that the Development Services Manager did not properly apply this section
7101.6, did not consider all of the relevant facts presented, made an error of fact or law,
abused discretion or acted arbitrarily and capriciously in the interpretation or
enforcement of the ACHD Policy Manual.
a. Filing Fee: The Commission may, from time to time, set reasonable fees to be
charged the applicant for the processing of appeals, to cover administrative
costs.
b. Initiation: An appeal is initiated by the filing of a written notice of appeal with
the Secretary and Clerk of the District, which must be filed within ten (10)
working days from the date of the decision that is the subject of the appeal.
The notice of appeal shall refer to the decision being appealed, identify the
appellant by name, address and telephone number and state the grounds for
the appeal. The grounds shall include a written summary of the provisions of
the policy relevant to the appeal and/or the facts and law relied upon and shall
include a written argument in support of the appeal. The Commission shall not
consider a notice of appeal that does not comply with the provisions of this
subsection.
c. Time to Reply: The Development Services Manager shall have ten (10)
working days from the date of the filing of the notice of appeal to r eply to the
notice of the appeal, and may during such time meet with the appellant to
discuss the matter, and may also consider and/or modify the decision that is
being appealed. A copy of the reply and any modifications to the decision
being appealed will be provided to the appellant prior to the Commission
hearing on the appeal.
d. Notice of Hearing: Unless otherwise agreed to by the appellant, the hearing of
the appeal will be noticed and scheduled on the Commission agenda at a
regular meeting to be held within thirty (30) days following the delivery to the
appellant of the Development Services Manager’s reply to the notice of
appeal. A copy of the decision being appealed, the notice of appeal and the
reply shall be delivered to the Commission at least one (1) week prior to the
hearing.
e. Action by Commission: Following the hearing, the Commission shall either
affirm or reverse, in whole or part, or otherwise modify, amend or supplement
the decision being appealed, as such action is adequately supported by the
law and evidence presented at the hearing.