Loading...
HomeMy WebLinkAboutSaguaro Canyon No. 1 FP 04-049 BEFORE THE MERIDIAN CITY COUNCIL C/C August 10, 2004 IN THE MATTER OF THE APPLICATION OF FARWEST, LLC FOR APPROVAL OF 50 SINGLE- FAMILY RESIDENTIAL BUILDING LOTS AND 15 COMMON LOTS ON 21.16 ACRES IN AN R-4 ZONE LOCATED NORTH OF EAST MCMILLAN ROAD AND EAST OF NORTH MERIDIAN ROAD IN A PORTION OF THE S Yz OF T.4N., R.1.E., SECTION 30 CASE NO. FP-04-049 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council for Fina] Plat approval pursuant to Meridian City Code § ]2-3-7 on August ]0, 2004, and the Council finding that the Administrative Review is complete /Tom Sonya Allen, Assistant City Planner for the Planning and Zoning Department, and Bruce Freckleton, Senior Engineering Technician for the Public Works Department, dated: Hearing Date: August 10, 2004, to the Mayor and Council, and the Council having considered the requirements of the preliminary plat the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Fina] Plat of"PLA T SHOWING SAGUARO CANYON SUBDIVISION NO.1 LOCATED IN A PORTION OF THE S Yz OF TAN., R.lE., SECTION 30, BOISE MERIDIAN, MERIDIAN, ADA COUNTY, IDAHO 2004, 40206 - PL T.DWG BEB ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR SAGUARO CANYON SUBDIVISION NO.1 / (FP-O4-049) Page 1 of3 OS/21/04 SHEET 1 OF 4, HANDWRITTEN DATE: 04/]9/04, BRIGGS ENGINEERING, INC.", FARWEST, LLC, Deve]oper, is Conditionally Approved subject to those conditions of Staff comments as set forth in the Memorandum to the Mayor and City Council /Tom Sonya Allen Assistant City Planner for the Planning and Zoning Department and Bruce Freckleton, Senior Engineering Technician for the Public Works Department, dated: Hearing Date: August 10, 2004, listing ]8 SITE SPECIFIC REQUIREMENTS/FINAL PLAT and 7 GENERAL REQUIREMENTS, a true and correct copy of which is attached hereto marked Exhibit "A", and consisting of 4 pages, and by this reference incorporated herein. 2. The final plat upon which there is contained the Certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 1. The Plat dimensions are approved by the City Engineer; and 2. The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The App]icant is hereby notified that pursuant to Idaho Code 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR SAGUARO CANYON SUBDIVISION NO. 1/ (FP-O4-O49) Page 200 request for a regulatory takings analysis will toll the time period within which a Petition for Judicia] Review may be filed. Please take notice that this is a final action of the governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty-eight (28) days after the date ofthis decision and order, seek ajudicia] review as provided by Chapter 52, Title 67, Idaho Code. By action of the City Council at its regular meeting held on the lO-th day of AulJù~ ,2004. Attest: BY:~ --~ City Clerk's Office Dated: O -24-04 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR SAGUARO CANYON SUBDIVISION NO. 1/ (FP-O4-049) Page30f3 MAYOR Tammy de Ween! olferi dtern IDAHO LEGAL DEPARTMENT (208) 466-9272 .Fax 466-4405 PUBLIC WORKS BUILDING DEPARTMENT (208) 887-2211 . Fax 887-1297 CITY COUNCIL MEMBERS Keith BiJd William LM. Nary Shaun WaldIe Charles M. Rountree PLANNING AND ZONING DEPARTMENT (208) 884-5533 . FAX 888-6854 STAFF REPORT: Hearing Date: August 10,2004 To: Mayor and City Council Sonya Allen, Assistant City Planner J-i ~ Bruce Freck]eton, Senior Engineering Tech. ~ From: Re: Saguaro Canyon Subdivision No.1 Fina] Plat approval of Fifty (50) Single-Family Residentia] Building Lots and Fifteen (15) Common Lots on 21.16 Acres in an R-4 Zone, by Farwest, LLC (File No. FP-O4-049). We have reviewed the above referenced submittals and offer the following comments, as conditions of approval. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION The applicant, Farwest, LLC, has applied for Fina] Plat approval of 50 single-family residential building lots and 15 common lots on 21.16 acres ofland for Saguaro Canyon Subdivision No.1. The zoning designation for the proposed subdivision is R-4 (Low Density Residential). This subdivision will have a gross density of 2.3] d.u.lacre and a net density of 3.05 d.u.lacre. Saguaro Canyon Subdivision No.1 is located on the north side of E. McMillan Road midway between N. Meridian Road and N. Locust Grove Road, in the S Yz of Section 30, TAN., RIE. The common area lots within the subdivision consist of landscape, open space, and pathway lots. The pressurized irrigation system within this development is to be owned and maintained by Settler's Irrigation District. The submitted final plat substantially complies with the approved preliminary plat. Staff recommends approval of Saguaro Canyon Subdivision No.1 with the comments and conditions stated in this report. SITE SPECIFIC COMMENTS 1 FINAL PLAT I. Applicant is to meet all terms of the approved Conditional Use Permit (CUP-03-058), Preliminary Plat (PP-03-032) and Development Agreement (Inst. No.1 04089430). FP-O4-049 Exhibit "A" Saguaro Canyon Sub.FP.doc Mayor & City Council Hearing Date: Ju]y 6, 2004 Page 2 2. Fencing must be in compliance with MCC 12-4-10. Temporary construction fencing will be required along the northern boundary of this phase to prevent debris /Tom blowing to adjacent properties during construction. 3. Revise the following notes on the face of the plat: a. b. Note #4: Add Lot 1, Block] and Lot ], Block 2 as non-buildable lots. Note #1]: CUP 92 ().2g CUP-03-058 which allowed for reduced ~ .... 4. The landscape plan shall be revised as follows: a. Show fencing adjacent to E. McMillan Road to match fencing proposed on the west and east boundaries ifberm is not constructed along McMillan Road. b. If proposing berm along McMillan Road, show contours and label as such. c. If proposing storm drainage swales, show contours. Submit three (3) copies of the revised landscape plan to the P&Z Department for review and approval prior to City Engineer signature of the final plat. 5. Graphically depict the 20' sewer and storm drain easement and address in the notes for Lots 1,2 & 8, Block 2. 6. If proposing storm drainage swales indicate "drainage" as a use in plat note #4. 7. The applicant has indicated that Settler's Irrigation District will own and maintain the pressure irrigation system within this development. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the irrigab]e common areas prior to signature on the final plat by the Meridian City Engineer. 8. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or latera] users association (ditch owners), with written approval or non-approval submitted to the Public Works Department. If latera] users association approval can't be obtained, plans will be reviewed and approved by the Meridian City Engineer prior to final plat signature. 9. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvements, including perimeter fencing, irrigation, and landscaping shall be installed and approved prior to obtaining certificates of occupancy. FP-O4-049 Exhibit "A" Saguaro Canyon Subl.FP.doc Mayor & City Council Hearing Date: Ju]y 6, 2004 Page 3 A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, amenities, sanitary sewer, water, etc., prior to signature on the final plat. 10. Sanitary sewer service to this site shall be via the existing temporary lift station built in the Cobre Basin Subdivision. Domestic water service to this site shall be via main line extensions /Tom mains installed adjacent to the property. App]icant will be responsible to construct the sewer and water mains to and through this proposed development, thereby making them available to adjacent properties. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. App]icant shall be subject to paying any applicable latecomers fees prior to city endorsement of the final plat maps. 11. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Reso]ution 02-374. 12. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate or discharge within a period of time not to exceed 24 hours for all storms up to and including a 1O0-year storm event. 13. App]icant shall submit a "FINAL" street name approval letter /Tom the Ada County Street Name Committee prior to signature on the final plat by the Meridian City Engineer. ]4. The sum of the segment distances across the north side of the subdivision boundary ITom Lot 16, B]ock 2 to Lot 12, Block 1, don't equal the overall boundary distance shown. Please make the necessary corrections. 15. The "Set Yz"x24" Rebar with Plastic Cap" symbol shown on the subdivision boundary adjacent to the South \<í Corner, should be revised to reflect "Set 5/8"x30" Rebar with Plastic Cap" since this is an angle point in the subdivision boundary. 16. Graphically depict 1 O-foot wide Public Utilities, Drainage and Irrigation easements on each side of the common lot line between Lots] & 13, Block 3, and Lots 4 & 5, Block 4. 17. All easements shown on the plat shall include a notation stating the purpose. ]8. Staff's failure to cite specific ordinance provisions, or terms of the approved Deve]opment Agreement, Conditional Use Permit, or Preliminary Plat does not relieve the App]icant of responsibility for compliance. GENERAL REOUIREMENTS FP-O4-049 Exhibit "A" Saguaro Canyon Subl.FP.doc 6. 7. Mayor & City Council Hearing Date: Ju]y 6, 2004 Page 4 1. Any tree over 4" in caliper that is removed /Tom the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be removed. 2. Any existing domestic wells and/or septic systems within this project will have to be removed ITom their domestic service per City Ordinance Section 9-]-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. Two-hundred-fifty watt & One-hundred watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Fina] design locations and quantity are determined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and permit /Tom the Public Works Department prior commencing installations. 4. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill rnaterial. 5. Applicant's engineer will be required to submit a signed, stamped statement certifYing that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. Coordinate fire hydrant placement with the City of Meridian Public Works Department. Deve]oper shall coordinate mailbox locations with the Meridian Post Office. STAFF RECOMMENDATION Staff recommends approval of the final plat with the above stated comments and conditions. FP-O4-049 Exhibit "A" Saguaro Canyon Subl.FP.doc