Loading...
HomeMy WebLinkAboutStaff Comments MAYOR TanunydeW- CfIY COUNCll. MEMBI!RS Keith Bird WilliamI.M.Nmy Sbaun Wardle Cbarleo M. _. A otr;ldt!l\ CfIY HAIL (208) 888-4433 - Fox 887-4813 PUBLIC WORKS BUILDING DEPARTMENT (2O8)887-22I1-Fox89S-9SS1 LEGAL DEPARTMENT (208) 46&-9272 - FAX 466-4405 STAFF REPORT: Hearing Date: September 28, 2004 To: Mayor, City Council and Planning & Zoning Commission Sonya Allen, Assistant City PlanneIJIf ~ Bruce Frecldeton, Senior Engineering Tech. ~ RECEIVED SEP 24 2004 From: Re: Sutherland Farm Subdivision No.4 City Of Meridian City Clerk Office . Request for Final Plat Approval of 79 Attached Single-family Residential Building Lots and 9 Common Lots on 16.3 Acres in an R-8 Zone for Sutherland Farm Subdivision No.4, by Sutherland Farm, Inc. (File No. FP- 04-058) We have reviewed the above-referenced submittal and offer the foUowing comments, as conditions of approvaL These conditions shaD be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION S~Y & LOCATION The applicant, Sutherland Farm, Inc., has requested approval for the fourth phase of Sutherland Farm Subdivision. This phase consists of 79 single-fiunily residential building lots and 9 common area lots on 16.3 acres in an R-8 zone. The gross density of Phase No.4 is approximately 3.29 dwelling units/acre. The net density is approximately 5.83 dwelling units/acre. Sutherland Farm Subdivision No.4 is located approximately \4 mile east of S. Eagle Road and y, mile north orE. Victory Rd. on the north side ofE. Easy Jet Drive (E. Girdner Ln.) in the SW V. of Section 21, T.3N., RIB. A Conditional Use Permit was approved for this phase that allowed reductions to the minimum requirements approved under the previous Conditional Use Permit (CUP-02-O05) for front yard setbacks (IO-feet for living areas & side entry garages, 20-feet for ftont entry garages), lot size (3,400 s.f. for attached dwellings), and minimum lot ftontages (34-feet for attached dwellings). Mayor & City Council Hearing Date: September 28, 2004 Page20f5 The final plat that was submitted substantially complies with the approved Preliminary Plat. One lot on the east side of Block 14 was shifted to the north along E. Quin Drive. Staff has no objection to this change since the number oflots stayed the same. Staff recommends approval of the fourth phase of Sutherland Farm Subdivision with the comments and conditions stated in this report. SITE SPECIFIC REOUlREMENTSlFINAL PLAT 1. Applicant shall meet all terms of the approved Rezone (RZ-04-006), Preliminsry Plat (pP-O4-O09), Planned Development (CUP-O4-009), and Development Agreement (Inst. #102143307). 2. The pressurized irrigation system within this development is to be owned and maintained by the Nampa & Meridian Irrigation District. The City of Meridian requires that pressurized inigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the culinsry water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Fencing shall be restricted to 4-feet in height on all building lots in Block 14 where they are contiguous to Lot 7 in compliance with MCC 12-4-10 and 12-13-15-9 and Conditional Use Permit Finding #3, page 4. 4. Sanitary sewer service to this site shall be via mainline extension from main lines installed in previous phases. Applicant will be responsible to construct the sewer mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Each lot within this subdivision shall be subject to paying sanitary sewer latecomers fees with the issuance of building permits. 5. Municipal water service to this site shall be via main line extensions from main lines in previous phases. Applicant will be responsible to construct the water mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Department. Each lot within this subdivision shall be subject to paying water latecomers fees with the issuance of building pennits. 6. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per ResohItion 02-374. 7. Complete recording information on the face of the plat for Sutherland Farm Sub. No.3. FP-04-058 Sutberland Fann SuM FP.doc Mayor & City Council Hearing Date: September 28, 2004 Page 3 of5 8. 9. 10. 11. 12. 13. Complete the Certificate of Owners and its accompanying Acknowledgement. Please clarify the relationship to the subdivision boundary of the Lot 1, Block 15 detail. The sum of the segments along the west side of Lots 73-76 and 88, Block 11 don't equal the corresponding overall distance shown. Please make the appropriate adjustments. Please revise the Landscape Plan dated 6/15/04, prepared by Tamura & Associates as follows: a. b. Show contours for all storm drainage swales. Five-foot pathways/micropaths are required to be paved. The symbol used for grasscrete appears to match these areas, please clarify/change symbol. Define the hatch marks shown along the pathway adjacent to the Ridenbaugh Canal (must be grass or bark with shrubs). Include proposed fencing on Landscape Plan as submitted by Daren Fluke, J-U-B Engineers on 9/23/04. c. d. Please add or revise the following plat notes: a. Revise note #1 to read: "Building setbacks and dimensional standards in this subdivision shall be in compliance with die appli(!llble ~eBiag regtdatieas ef die City efMeridilHl, Idalia. Title 11 and Title 12 of the Meridian Citv Code unless otherwise modified by Conditional Use Permit (CUP-O4-O09). which allowed for reductions in lot size. front vard setbacks. and street frontage." Note #11: Complete recording information. b. Staffs failure to cite specific ordinance provisions or terms of the approved Rezone, Preliminary Plat, Conditional Use Permit or Development Agreement does not relieve Applicant of responsibility for compliance. GENERAL REOUIREMENTS 1. 2. FP..04-05S All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association, with written confirmation of said approval submitted to the Public Works Department. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. Sutherland Fann SuM FP.doc Mayor & City Council Hearing Date: September 28, 2004 Page40f5 3. 4. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvements, including fencing, micro-paths, irrigation, and landscaping shall be installed and approved prior to obtaining certificates of occupancy. A letter of credit or cash surety in the amount of 110% will be required for all fencing, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. Two-Hundred-fifty watt (25Ow) and One-Hundred watt (WOw), high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. Street light contractor to obtain design and permit from the Public Works Department prior commencing installations. 5. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 6. Submit "Final" letter from the Ada County Street Name Committee, approving the subdivision and street names. Make any corrections necessary to conform. 7 Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 8. Coordinate fire hydrant placement with the City of Meridian's Water Deputy Fire Chief and the Public Works Department. 9. Provide five-foot-wide sidewalks in accordance with City Ordinance Section 12-5-2.K. Sidewalks are to provide a clear five-foot-wide walkway pathway without encroachment of mailbox structures. 10. All development shall comply with the Americans with Disabilities Act and the Fair Housing Act. 11. No building permits shall be issued within the development until a final plat has been recorded for this subdivision. RECOMMENDATION Staff recommends approval of the final plat for Sutherland Farm Subdivision No.4 with the above stated comments and conditions. FP.Q4-O5S SuIherland Farm SuM FP.doc Mayor & City Council Hearing Date: September 28, 2004 Page 5 of5 FP-04-058 Su1herlaod Fann SuM FP.doc