HomeMy WebLinkAboutStaff CommentsMAYOR
Tammy de Weerd
CITY COUNCIL MEMBERS
Keith Bird
William L.M. Nary
Shaun Wardle
Charles M. Rountree
LEGAL DEPARTMENT
(208)466-9272 Fax 466-4405
PUBLIC WORKS
BUILDING DEPARTMENT
(208) 887-2211 ~ Fax 887-1297
PLANNING AND ZONING
DEPARTMENT
(208) 884-5533 ~ FAX B88-6854
STAFF REPORT:
To: Mayor and City Council ,(~
From: Sonya Allen, Assistant City Planner V ~
John Boyd, Engineering Tech. II q~
Re: Burney Glen Subdivision No. 2 O''
Hearing Date: July 13, 2004
lUl. 0 9 2004
~Jity Of tUleridiarc
City Clerk Office
Final Plat approval of Thirty-two (32) Single-Family Residential Building Lots
and Four (4) Common Lots on 9.34 Acres in an R-8 Zone, by Properties West,
Inc. (File No. FP-04-042).
We have reviewed the above referenced submittals and offer the following comments, as
conditions of approval. These conditions shall be considered in full, unless expressly
modified or deleted by motion of the Meridian City Council:
APPLICATION SUMMARY & LOCATION
The applicant, Properties West, Inc., has applied for Final Plat approval of 32 single-family
residential building lots and 4 common lots on 9.34 acres of land for Burney Glen Subdivision
No. 2. The zoning designation for the proposed subdivision is R-8 (Medium Density
Residential). This phase of the subdivision will have a gross density of 3.53 d.u./acre and a net
density of 4.5 d.u./acre.
The common area lots within the subdivision consist of landscape, open space, pathway, and
drainage lots. The pressurized irrigation system within this development will be owned and
maintained by Settler's Irrigation District.
Burney Glen Subdivision No. 2 is located on the east side of N. Meridian Road, approximately
mile south of E. McMillan Road, in the NW '/< of Section 31, T.4N., R.1 E.
The submitted fmal plat substantially complies with the approved preliminary plat. Staff
recommends approval of the fmal plat with the comments and conditions stated in this report.
FP-04-042 Bumey Glen Sub2 FP.doc
Mayor & City Council
Hearing Date: July 13, 2004
Page 2
SITE SPECIFIC COMMENTS /FINAL PLAT
1. Applicant shall meet all terms of the approved Annexation (AZ-02-026) and Preliminary
Plat (PP-02-025).
2. A detailed fencing plan must be submitted for the northern boundary of the subdivision
unless fencing already exists at this location. Fencing must be in compliance with MCC
12-4-10.
Temporary construcfion fencing to contain debris shall be installed along the boundaries
of this phase unless fencing already exists at the subdivision boundaries.
3. The pressurized irrigation system within this development is to be owned and maintained
by Settler's Irrigation District. The City of Meridian requires that pressurized irrigation
systems be supplied by a year-round source of water. If a creek or well source is not
available, asingle-point connection to the culinary water system shall be required. Plans
and specifications for the irrigation system shall be reviewed by the Public Works
Department as part of the development plan review process, and a draft copy of the
pressurized irrigation system O&M manual must be submitted prior to plan approval. If a
single-point connection is utilized, the developer shall be responsible for the payment of
assessments for the irrigable common areas prior to signature on the final plat by the
Meridian City Engineer.
4. Street signs are to be in place, water system shall be approved and activated, pressurized
irrigation system approved and activated, drainage lots constructed, fencing installed, and
road base approved by the Ada County Highway District prior to applying for building
permits. All development improvements, including perimeter fencing, irrigafion, and
landscaping shall be installed and approved prior to obtaining certificates of occupancy.
A letter of credit or cash surety in the amount of 110% will be required for all fencing,
landscaping, pressurized irrigation, amenities, sanitary sewer, water, etc., prior to
signature on the final plat.
5. Sanitary sewer and municipal water services to this site shall be via extensions from
existing mains. Applicant will be responsible to construct the sewer and water mains to
and through this proposed development, thereby making them available to adjacent
properties. Subdivision designer to coordinate main sizing and routing with the Public
Works Department. Applicant shall execute City of Meridian standard forms of
easements, for any mains that are required to provide service.
6. Applicant shall be required to pay Public Works development plan review, and
construction inspection fees, as determined during the plan review process, prior to
signature on the final plat per Resolution 02-374.
7. Any drainage areas (detention retention basins) must be designed to ensure that water
will percolate or discharge within a period of time not to exceed 24 hours for all storms
up to and including a 100-year storm event.
FP-04-042 Burney Glen Sub2 FP.doc
Mayor & City Council
Hearing Date: July 13, 2004
Page 3
8. Submit a signed street name evaluation letter prior to signature on the final plat,
9. Re-locate landscape island (Lot 1, Block 9) to the west so that it aligns with the common
lot line on Lots 8 & 9, Block 4 or otherwise demonstrate that Lot 9, Block 4 and Lot 13,
Block 5 will have adequate driveway access.
10. Revise note #8 on the face of the plat to include Lot 2, Block 11 as a common lot.
11. Revise note #3 to include a 10-foot easement on rear lot lines of interior lots as well as
lots on the exterior boundary of the subdivision.
12. Please add the CP & F # of the Center'/ Comer of Section 31.
13. Please depict the street width dimensions on E. Vestige Drive.
14. Please add the Recorded Instrument No. for the Storm Drainage easement(s) referred to
in Note 14.
15. The storm drainage area that is shown to have a sand infiltration gallery on the landscape
plan shall be revised to be in compliance with MCC 12-13-14 Stormwater Integration.
This area will need to be seeded. Sand is not allowed on the surface of required landscape
areas.
16. Sign the Certificate of Owners and notarize the accompanying Acknowledgment (Sheet 2
of the final plat).
17. Staff s failure to cite specific ordinance provisions, or terms of the approved annexation
or preliminary plat does not relieve the Applicant of responsibility for compliance.
GENERAL REOUIREMENT5
Any tree over 4" in caliper that is removed from the property shall be replaced by
installing additional trees, being the equivalent number of caliper inches of trees that
were removed. Required landscaping trees will not be considered as replacement trees for
those trees that have to be removed.
2. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting,
crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per
City Ordinance 12-4-13. Plans will need to be approved by the appropriate
irrigation/drainage district, or lateral users association (ditch owners), with written
approval or non-approval submitted to the Public
association approval can't be obtained, plans wil
Meridian City Engineer prior to final plat signature
Works Department. If lateral users
1 be reviewed and approved by the
FP-04-042 Burney Glen Sub2 FP.doc
Mayor & City Council
Hearing Date: July 13, 2004
Page 4
3. Any existing domestic wells and/or septic systems within this project will have to be
removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells
may be used for non-domestic purposes such as landscape irrigation.
4. One-hundred-watt, high-pressure sodium streetlights will be required at locations
designated by the Public Works Department. All streetlights shall be installed at
subdivider's expense. Typical locations are at street intersections and/or fire hydrants.
Final design locations and quantity aze determined after power designs are completed by
Idaho Power Company. The street light contractor shall obtain design and permit from
the Public Works Department prior commencing installations.
5. Compaction test results must be submitted to the Meridian Building Department for all
building pads receiving engineered backfill, where footing would sit atop fill material.
6. Applicant's engineer will be required to submit a signed, stamped statement certifying
that all street finish centerline elevations are set a minimum of three feet above the
highest established normal groundwater elevation.
Coordinate fire hydrant placement with the City of Meridian Public Works Department.
8. Developer shall coordinate mailbox locations with the Meridian Post Office.
STAFF RECOMMENDATION
Staff recommends approval of the final plat with the above stated comments and conditions.
FP-04-042 Bumey Glen Sub2 FP.doc