Solitude Place No. 3 Planner: Bill Parsons
Dimensional Standards:
R-8 Standard Requirement
Rear setback (ft.) 12’
Interior side setback (ft.) (In some cases, there may be a greater setback due to a wider utility
easement - refer to the recorded plat for specific easement information.) 5’
Street setback1
to garage (ft.)
Local 20’
Street setback1
to living area (ft.)
Local 15’
Maximum building height (ft.) (as defined by the Building Code) 35’
Note: 1
Measured from back of sidewalk or property line where there is no adjacent sidewalk.
Parking Standards for Dwellings (single-family detached):
Number of Bedrooms
(per unit) Required Parking Spaces
1
1 2 per dwelling unit; at least 1 in an enclosed garage, other space may be enclosed or a
minimum 10’ x 20’ parking pad2
2/3/4 4 per dwelling unit; at least 2 in an enclosed garage, other spaces may be enclosed or a
minimum 10’ x 20’ parking pad2
5+ 6 per dwelling unit; at least 3 in an enclosed garage, other spaces may be enclosed or a
minimum 10’ x 20’ parking pad2
Notes:
1The size of the garage or carport required for dwelling units shall be measured by exterior dimensions & shall be
at least 10’ x 20’ for a 1 space garage or carport and 20’ x 20’ for a 2 space garage or carport.
2The parking pad shall be measured from the edge of sidewalk or edge of paved travel lane (public street, private
street, or alley) where no sidewalk exists.
Fencing (UDC 11-3A-7): All proposed fencing in residential districts shall comply with the following:
Maximum fence height allowed 6’
Front yard 3’ solid or 4’ open vision fencing
Street side yard 3’ solid or 4’ open vision fence at the property line or 6’ fence set back 10’
from property line
Rear yard 6’ (unless adjacent to interior common area or pathway – see below)
Fencing adjacent to interior common
lot or pathway (side or rear) 4’ solid or 6’ open vision fence (6’ solid is prohibited)