HomeMy WebLinkAboutFire Department Comments ",rt>V~ vmcc TAMMY DE WEERD COUNCIL MEMBERS WILLIAM LM. NARY KEITH BIRD CHARLIE M. ROUNTREE SHAUN WARDLE otre;;diaH \ ~ IDAHO ¡'.¡;' 1, .or ~ "TR"='_V~ FIRE DEPARTMENT KEN W. BOWERS DEPUTY CHIEF - FIRE PREVENTION JOSEPH SILYA o~,,~~.. .~-- DEPUTY CHJEF - TRAINING BILL JOHNSON 540 East Franklin Road Meridian. ID 83642 (208) 888-1234 Fax (208) 895-0390 RURAL FIRE COMMISSIONERS RICHARD GREENE TERRY LEIGHTON MERIDIAN June 21,2003 TO: Mayor De Weerd & Meridian City Council Joseph Silva, Deputy Chief, Fire Prevention RECEIVEr) JUN 2 3 2004 FROM: Of l\1eridjru Clerk Office SUBJECT: Autumn Faire Crossing FP 04-038 The following will be the requirements and/or concerns to provide minimum levels of fire protection for the proposed project: 1. One and two family dwellings will require a fire-flow of 1,000 gallons per minute available for duration of 2 hours to service the entire project. Fire hydrants shall be placed an average of 400' apart. International Fire Code Appendix D 2. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 3. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. a. Fire Hydrants shall have the 4 y," outlet face the main street or parking lot aisle. b. The Fire hydrant shall not face a street which does not have addresses on it. c. Fire hydrant markers shall be provided per Public Works spec. d. Locations with fire hydrants shall have the curb painted red 10' to each side ofthe hydrant location. e. Fire Hydrants shall be placed on comers. f. Fire hydrants shall not have any vertical obstructions to outlets within 10'. 4. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have an turn-around. 5. All entrance and internal roads shall have a turning radius of28' inside radius and 48'outside radius. 6. Operational fire hydrants and temporary or pennanent street signs are required before combustible construction begins. 7. To increase emergency access to the site a minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. The applicant shall provide a stub street to the property to the (westleastlnorthlsouth). The two entrances shall be separated by no less than Y, the diagonal measurement of the project. 8. All portions of the buildings located on this project must be within 150' of a paved surface as measured around the perimeter of the building.