Loading...
HomeMy WebLinkAboutBaldwin Park Subdivision No. 8 FP-04-030 BEFORE THE MERIDIAN CITY COUNCIL CIC 05/18/04 ~- IN THE MATTER OF THE APPLICATION OF CAPITAL DEVELOPMENT, INC. FOR APPROVAL OF 30 SINGLE FAMILY RESIDENTIAL BUILDING LOTS AND 6 COMMON LOTS ON 9.01 ACRES IN AN R-8 ZONE, LOCATED APPROXIMATELY ';4 MILE EAST OF N. LINDER ROAD AND ';4 MILE SOUTH OF W. MCMILLAN ROAD IN T.4N., R.IW., SECTION 36. CASE NO. FP-O4-030 ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT This matter coming before the City Council for Final Plat approval pursuant to Meridian City Code § 12-3-7 on May 18, 2004, and the Council finding that the Administrative Review is complete from Sonya Allen for the Planning and Zoning Department, and Bruce Freckleton, Engineering Technician III, dated: City Council Date: May 18, 2004, to the Mayor and Council, and that Anna Powell Planning Director for the Planning and Zoning Department, commented at the hearing, and the Council having considered the requirements of the preliminary plat the Council takes the following action: IT IS HEREBY ORDERED THAT: 1. The Final Plat of "PLAT OF BALDWIN PARK NO. 8 SUBDIVISION, A PORTION OF SECTION 36, TAN., R.IW., B.M., MERIDIAN, ADA COUNTY, IDAHO, 2004, HANDWRITTEN DATE: 04/6/04, CAPITAL DEVELOPMENT INC., DEVELOPER, BOISE, ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR BALDWIN PARK SUBDIVISION NO.8 1 (FP-04-030) Page 1 of3 IDAHO, BRIGGS ENGINEERING, INC., CONSULTING ENGINEERS, BOISE, IDAHO, SHEET 1 OF 2, 30806-PL T.DWG BEB 04/06/04 STAMPED DATE: APR 192004", Capital Development, Inc., Developer, is Conditionally Approved subject to those conditions of Staff comments as set forth in the Memorandum to the Mayor and City Council from Bruce Freckleton, Engineering Technician III, and Sonya Allen for the Planning and Zoning Department, dated: City Council Date: May 18, 2004, listing 15 SITE SPECIFIC REQUIREMENTS, and 8 GENERAL REQUIREMENTS, a true and correct copy of which is attached hereto marked Exhibit' A', and consisting of four pages, and by reference incorporated herein. 2. The final plat upon which there is contained the Certification and signature of the City Clerk and the City Engineer verifying that the plat meets the City's requirements shall be signed only at such time as: 1. The Plat dimensions are approved by the City Engineer; and 2. The City Engineer has verified that all off-site improvements are completed and/or the appropriate letter of credit or cash has been issued guaranteeing the completion of off-site and required on-site improvements. NOTICE OF FINAL ACTION AND RIGHT TO REGULATORY TAKINGS ANALYSIS The Applicant is hereby notified that pursuant to Idaho Code 67-8003, the Owner may request a regulatory taking analysis. Such request must be in writing, and must be filed with the City Clerk not more than twenty-eight (28) days after the final decision concerning the matter at issue. A request for a regulatory takings analysis will toll the time period within which a Petition for Judicial Review may be filed. ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR BALDWIN PARK SUBDIVISION NO.8 1 (FP-04-030) Page 2 of 3 Please take notice that this is a final action ofthe governing body of the City of Meridian, pursuant to Idaho Code § 67-6521. An affected person being a person who has an interest in real property which may be adversely affected by this decision may, within twenty- eight (28) days after the date of this decision and order, seek a judicial review as provided by Chapter 52, Title 67, Idaho Code. By action of the City Council at its regular meeting held on the 18+h day of mOJj ,2004. By: Attest: BY:~~íL' .t...O ðAr-- Dated: .JUri' I, ?m4 dc\Z:\WorkIM\MeridianlMeridian IS360MlBaldwin paIk Sub No.8 FP-04-O30\OrderFP.doc ORDER OF CONDITIONAL APPROVAL OF FINAL PLAT FOR BALDWIN PARK SUBDIVISION NO.8 1 (FP-04-030) Page3 of3 MAYOR Tanuny de Weerd CITY HALL (208) 888-4433 - Fax 887-4813 PUBLIC WORKS BUILDING DEPARTMENT (208)887-2211-Fax 898-9551 CITY COUNCIL MEMBERS Keith Bird William LM. Nary Shaull Wardle Charles M. Rountree LEGAL DEPARTMENT (208) 466-9272 - FAX 466-4405 STAFF REPORT: City Council Date: May 18, 2004 From: Mayor & City Council Sonya Allen, Assistant City Plarmer ¿II. d Bruce Freckleton, Engineering Tech III ~ To: Re: Baldwin Park Subdivision No.8 Request for Pinal Plat approval of Thirty (30) Single-Family Residential Building Lots and Six (6) Other Lots on 9.01 Acres in an R-8 Zone, by Capitol Development (File No. FP-O4-030). We have reviewed this submittal and offer the following comments, as conditions of the applicant. These conditions shall be considered in full, unless expressly modified or deleted by motion of the Meridian City Council: APPLICATION SUMMARY & LOCATION This is the eighth phase of the Baldwin Park Subdivision, located approximately \4 mile east of N. Linder Road and \4 mile south ofW. McMillan Road in TAN., R.l W., Section 36. This phase of the subdivision includes 30 single family residential building lots and 6 common lots on 9.01 acres in an R-8 zone. The gross density of Phase No.8 is approximately 3.32 dwelling units/acre. The net density is approximately 4.37 dwelling units/acre. Staff finds that the final plat substantially complies with the approved preliminary plat (PP-03- 038). There was one common lot added in Block 4 and one in Block 17 for street buffer landscaping. There was also a building lot removed in Block 17 and one in Block 16. Staff has no objections to these changes. Staff recommends approval of this phase of Baldwin Park Subdivision with the comments and conditions stated in this report. Exhibit' A' Page 1 of 4 Mayor & City Council Hearing Date: May 18, 2004 Page 2 of 4 SITE SPECIFIC REOUIREMENTS 1. Applicant shall meet all terms of the approved Annexation (AZ-03-033), Preliminary Plat (PP-03-038) and Development Agreement (Inst. No. 102083000). 2. The pressurized irrigation system within this development is to be owned and maintained privately by the Baldwin Park Subdivision Homeowner's Association. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, a single-point connection to the culinary water system shall be required. Plans and specifications for the irrigation system shall be reviewed by the Public Works Department as part of the development plan review process, and a draft copy of the pressurized irrigation system O&M manual must be submitted prior to plan approval. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvements, including fencing, micro-paths, irrigation, and landscaping shall be installed and approved prior to obtaining certificates of occupancy. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 4. All fencing shall be in compliance with MCC 12-4-10. 5. Please revise the Landscape Plan dated 4-13-04 (L-l & L-2), prepared by The Land Group, Inc. as follows: a. Show contours of swales on all drainage lots. Drainage swales must be in compliance with MCC 12-13-14 Stonnwater Integration. 6. Add or revise the following plat notes: a. Revise Note #14 to read: "Fencing adjacent to the micropath on Lot 52. Block .l.b. Èletweeli tliø J'la!fl. IIfld the FeiH" let lilies of Lots 5Q, 51 and 53 Bloek 12 shall be limited to a (4) foot tall fence if solid building materials are used. This requirement affects Lots 50. 51. and 53. Block 12." 7. Correct the distance ofLl4 in the Line Table. 8. Sanitary sewer service to this site shall be via the White Drain Trunk. Applicant will be responsible to construct the sewer mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Exhibit 'A' Page 2 of 4 14. 15. Mayor & City Council Hearing Date: May 18, 2004 Page 3 of 4 Department. 9. Municipal water service to this site shall be via main line extensions from mains installed in previous phases. Applicant will be responsible to construct the water mains to and through this proposed development. 10. Complete the Certificate of Owners and accompanying Acknowledgment. 11. Applicant shall be required to pay Public Works development plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. 12. Revise the plat to graphically depict an eight foot (8') wide public utilities, drainage and irrigation easement along the east side of Lot 7, Block 17, as this will be a side lot line adjacent to future development. 13. There are several boundary line bearing and distance calls that don't match the corresponding callouts of the previous Baldwin Park No.7 Subdivision Plat. Make the necessary corrections to comply. Any drainage areas (detention/retention basins) must be designed to ensure that water will percolate or discharge within a period of time not to exceed 24 hours for all stonns up to and including a 100-year stonn event. (All areas being counted toward the 10% open space amenity shall be free of "wet ponds" or other such nuisances.) Staff's failure to cite specific ordinance provisions or terms of the approved preliminary plat or development agreement does not relieve Applicant of responsibility for compliance. GENERAL REOUIREMENTS 1. 2. 3. All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association, with written confinnation of said approval submitted to the Public Works Department. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-S. Wells may be used for non-domestic purposes such as landscape irrigation. One-Hundred watt (1O0w), high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Exhibit 'A' Page 3 of 4 Mayor & City Council Hearing Date: May 18, 2004 Page 4 of 4 Final design locations and quantity are determined after power designs are completed by Idaho Power Company. Street light contractor shall obtain design and pennit approval from the Public Works Department prior to commencing installations. 4. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 5. Sewer and water mains shall be extended to and through the proposed development, thereby making services available for adjacent properties. 6. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 7. Coordinate fire hydrant placement with the City of Meridian's Water Deputy Fire Chief and the Public Works Department. 8. Provide five-foot-wide sidewalks in accordance with City Ordinance Section l2-5-2.K. Sidewalks are to provide a clear five-foot-wide walkway pathway without encroachment of mailbox structures. RECOMMENDATION Staff recommends approval of Baldwin Park Subdivision No.8 with the above stated comments and conditions. Exhibit 'A' Page 4 of 4