Loading...
HomeMy WebLinkAboutYMCA Modular Building - Siena Elementary School - Storm Water Management & Engineering Drainage ReportI%"% /ice tm 00 `` L� ter' THIS LAND GROUP, INC. YMCA Modular Building Siena Elementary School Meridian, Idaho Storm Water Management & Engineering Drainage Report Treasure Valley Family YMCA Contact: Robert Park 1177 W. State St. Boise, Idaho 83702 Ph: 208.344.5502 Engineer The Land Group, Inc. 462 A aldaho 83616 e, Suite 100 EagleContact: Jason Densmer, PE Ph: 208.939.4041 141- OF ��,'�' ,V DENa'% June 26, 2014 Project No. 114105 Site Planning • Landscape Architecture - Civil Engineering - Golf Course Irrigation & Engineering - Graphic Design - Surveying 462 E. Shore Drive, Suite 100 • Eagle, Idaho 83616 • P 208.939.4041 - F 208.939.4445 - www.the.landgroupinc.com r THE LAND GROUP, INC. Report Purpose YMCA Modular Building Meridian, Idaho Storm Water Management Report The following report addresses the storm drainage systems proposed for the YMCA Modular Building to be located in the southeast corner of the Siena K8 Magnet School which is located on the north side of E. Rome Dr. in Meridian, Idaho. Calculations are provided demonstrating that the project provides suitable drainage systems to accommodate anticipated stormwater flows. Peak Precipitation Rates The drainage systems have been designed to store the 100 -year, 1 -hour event. The drainage calculations are shown in Appendix A. Peak Stormwater Flows & System Performance Site Drainage Areas The site comprises a single tributary area. Generally, the drainage from the building roof and attached planter beds. The runoff will sheet flow from the roof area to rain gutters flowing to four downspouts, one at each corner of the building. The downspouts will drain into a grated inlet that is piped to a subsurface piping system. Direct rainwater that is collected in the planter beds will infiltrate through topsoil and be collected in the storm drain piping system. The subsurface piping system will direct the runoff to a subsurface seepage bed designed to hold the 100 -year event storm runoff. Over time the seepage bed will allow the runoff to infiltrate into the natural sub -soils. The following calculations show that the proposed facilities are adequately sized to accommodate the expected storm water runoff from the site. Ar Site Planning • Landscape Architecture • Civil Engineering • Golf Course Irrigation & Engineering • Graphic Design • Surveying 462 E. Shore Drive, Suite 100 - Eagle, Idaho 83616 • P 208.939.4041 • F 208.939.4445 • www.thelandgroupinc.com • THE LAND GROUP, INC. Appendix A 5tormwater Calculations YMCA Modular Building Meridian, Idaho Storm Water Management Report A, Site Planning • Landscape Architecture • Civil Engineering • Golf Course Irrigation & Engineering • Graphic Design • Surveying 462 E. Shore Drive, Suite 100 • Eagle, Idaho 83616 • P 208.939.4041 • f 208.939.4445 • www.thelandgroupinc.com S� �� THE LAND GROUP, INC. YMCA (Siena Elementary) (PN 114105) Storm Drainage Calculations Drainage Area Total Area =s.f. Impervious Area =s.f. Landscape Area =s.f. wt. C =1E 8.0 C = 0.95 C = 0.20 4.0 50.0 2.85 Retention System Design Infiltration Trench Characteristics Infiltration Rate = Bed Bottom Width = Bed Bottom Length = Storage Depth = Bed Bottom Area = Voids = A perc. = Q perc. = 8.0 in/hr` ft. ft. ft. s.f. s.f. cf/hr 4.0 50.0 2.85 200.0 40% 200 133 June 26, 2014 Storage Volume Required (100 Year Return Period) Time (hr) Time (min) Time (sec) Intensity (in/hr Q dev. (cfs) V dev. (c. f) V inf. (cf . ) V St. (c.f.) 0.17 10 600 3.11 0.25 153 22 131 0.25 15 900 2.62 0.21 193 33 160 0.33 20 1,200 2.28 0.19 224 44 180 0.50 30 1,800 1.82 0.15 268 67 202 0.67 40 2,400 1.37 0.11 269 89 180 0.83 1 50 3,000 1 1.17 0.10 1 287 111 176 1.0 60 3,600 1.15 0.09 339 133 206 2.0 120 7,200 0.66 0.05 389 267 122 3.0 180 10,800 0.48 0.04 425 400 25 6.0 360 21,600 0.36 0.03 637 800 -163 12.0 720 43,200 0.19 0.02 672 1,600 -928 24.0 1,440 86,400 0.12 0.01 849 3,200 -2,351 Site Planning - LandscapeArchiteaure - Civil Engineering - GoofCowse Irrigation & Eogineering • Graphic Communication - Surveying 462E. ShoreDrive, Ste. 100, Eagle, Idaho 83616 - P208.939.4041 F208.939.4445 - navw.thelandgroupinccam On Site Drainage (continued) VSp =1 228 I c.f. Infiltration Volume Check: V(90%) = 764 cf Vperc = 3,200 cf Seepage Bed Recovery Time: Vs Max= 849 cf Q perc = 133 cf per hr THE LAND GROUP, INC. , Required Storage Volume Total Volume Provided ,90% of maximum runoff developed in 24 -hours —Total Percolation Volume in 24 -hours ,Maximum Runoff Developed Site Planning -Landscape Architecture - Ciad Engineering Golf Course Irrigation 6—Engineenng , Graphic Communication Surveying 462E. ShoreDrive, Ste. 100, Eagle, Idaho 83616 P 208.939.4041 F 208.939.4445 - wwruthelandgroupinc.co>n