Loading...
HomeMy WebLinkAboutStaff CommentsMAYOR Tammy de Weard Cn'Y COUNCIL MEMBERS Keith Bird William L.M Nary Shaun Wardle Charles M. RauMree CITY OF eri~i~n Il IDAHO crrY xAta. (208) 888-4433 -Fax 587-4813 PUBLIC WORKS BUILDING DEPARTMENT (208) 887-2211 - Fex 898-9331 LEGAL DEPARTMENT (208)466.9272 -FAX 466.4403 STAFF REPORT: Hearing Date: Apri120, 2004 To: Mayor, City Council and Planning 8t Zoning Commission t 4~~ C.r.L,r,1~ ~/ ~j (~~J~' APR 16 2004 From: Wendy Kirkpatrick, AICP, Associate City Planner VW I "' -,. Bruce Freckleto Senior F.n ineerin Tech. fJTt9 Of Meridian ~ g g ~ sty Clerk Oflice Re: Sageland Subdivision Request for Final Plat Approval of 41 Single-family Residential Building Lots on 10.64 Acres in an R-8 Zone for Sageland Subdivision, by Quasar Development, LLC. (Fide No. FP-04-024) We have reviewed the above-referenced submittal and ofFer the following comments, as conditions of approval These conditions shall be considered in full, unless ezpressty modified or deleted by motion of the Meridian City Counc~7: APPLICATION SL~Ma1tY ~ LOCATION The applicartt, Quasar Development, LLC has requested approval for Sageland Subdivision. This subdivision consists of 41 single-family residential building lots and 10 common area lots on 10.64 acres in an R 8 zone. The gross density is approximately 3.85 dwelling units/acre. The net density is approximately 4.69 dwelling unit acre. Sageland Subdivision is located at the northeast corner of Victory Road and Locust Grove Road. A Conditional Use Permit for a Planned Development was approved for this project. The CUP allowed for the minimum lot size to be reduced to 5,000 s.f. for detached homes and fora 5' rear setback for garages. A revised landscape plan needs to be submitted depicting the addition of roadside infiltration swales to the subdivision plat. The swales were required by ACHD after the preliminary plat was approved by Council. The addition of the swales will result in the proposed subdivision's sidewalks being shifted to an easement on the subdivision lots. Approximately 2' of the width of the sidewalks will be located inside the subdivision lots. With this added condition, staff has no Mayor & City Council Hearing Date: Apri120, 2004 Page 2 of 5 objection to the sidewalk easement. Staff has added a condition stating that setbacks shall be measured from the sidewalks not property line. Staff recommends approval of Sageland Subdivision with the comments and conditions stated in this report. SITE SPECIFIC 1tE0UIItEMENTS/FINAL PLAT Applicant shall meet all terms of the approved Preliminary Plat (PP-03-020), Planned Development (CUP-03-036), Annexation and Zoning (AZ-03-015) and Development Agreement (Inst. #104033485). 2. The pressurized irrigation system within this development is to be owned and maintained by the Nampa & Meridian Irrigation District. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round source of water. If a creek or well source is not available, asingle-point coffiection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the paymern of assessmerns for the common areas prior to signature on the final plat by the Meridian City Engineer. 3. A revised landscape plan must be submitted depicting the roadside infiltration swales and all trees which will be relocated from the originally approved landscape plan due to the addition of the swales. 4. Sidewalk easements and shared driveways must be depicted on the revised final plat. 5. Fencing shall be constructed in conformance with the Preliminary Plat Findings of Fact and Conclusions of Law and MCC 12-4-10. 6. Sanitary sewer service to this site shall be via mainline extension from the trunk line installed for the Tuscany Village development. Applicant will be responsible to construct the sewer mains to and through this proposed development. Subdivision designer to coordinate main sizing and routing with the Public Works Department. 7. Municipal water service to this site shall be via main line extensions from existing mainlines installed adjacent to the proposed development. Applicant will be responsible to construct the water mains to and through this proposed development. 8. Applicant shall be required to pay Public Works developmern plan review, and construction inspection fees, as determined during the plan review process, prior to signature on the final plat per Resolution 02-374. 9. Complete the Certificate of Owners and its accompanying Acknowledgement. FP-04-024 3ageland Subdivi~on FP.doc Mayor & City Council Hearing Date: Apri120, 2004 Page 3 of 5 10. The bearing and distance calls on the face of the plat don't match the bearing and distance calls in the legal description of the Certificate of Owner's. Please make the appropriate revisions. 11. Graphically depict eight (8') foot wide public utilities, drainage and imgation easements along the south side of Lot 13, Block 2, and the north side of Lot 6, Block 2. The extra width is required due to the location of the pressurized irrigation mains. 12. Applicarn shall add a pennanern shared access easement, centered on the lot line between Lots 17 & 18, and Lots 19 & 20 Block 2; Lots 17 & 18, Block 1 for the purpose of a common driveway. The access easemem shall be a minimum 20 feet wide by 20 feet long for Lots 17-20, Block 2, and 40 feet long for Lots 17 & 18, Block 1. Add a reference for each case to plat Note #9. 13. Please revise the Landscape Plan as follows: a. Stormwater swales must meet standards outlined in Section 12-13-14-2a of Meridian's Zoning Ordinance. b. Contour lines must be shown on landscape plan. c. Roadside infiltration swales must be shown on landscape plan. d. Show where trees which were originally located in the swale areas will be relocated. 14. Please add or revise the following plat notes: 6. All rear lot lines and those common to a public right-of--way have a ten (10') foot wide permanent public utilities, drainage, street light and irrigation easement, except for those lots with sidewalk encroachment, in those cases the easement width shall be twelve(12) foot. 9. Re-word.• A cross access easement is herby dedicated for the purpose of shared driveways. 11. Complete recording information. 12. The owner of each lot across which passes an irrtgation/drainage ditch or pipe, is responsible for the maintenmace therof, unless such responsibility is assumed by an irrigation/drainage district. 13. Front yard setbacks shall be measured from back of sidewalk for lots where sidewalk encroaches into lot. 14. Building setbacks and dimensional standards in this subdivision shall be in compliance with Title ]I and Title I2 of the Meridian City Code unless otherwise mod~ed by Conditional Use Permit (CUP-03-036) which allowed for reduced setbacks and lot sizes. 15. Staff's failure to cite specific ordinance provisions or terms of the approved preliminary plat, conditional use permit or development agreement does not relieve Applicant of responsibility for compliance. FP-04-024 Sageland Subdivi~on FP.doc Mayor & City Council Hearing Date: Apti120, 2004 Page 4 of 5 GENERAL REQUIREMENTS All irrigation ditches, laterals or canals, exclusive of natural waterways, intersecting, crossing or lying adjacent and contiguous to the area being subdivided shall be tiled per City Ordinance 12-4-13. Plans will need to be approved by the appropriate irrigation/drainage district, or lateral users association, with written confirmation of said approval submitted to the Public Works Department. 2. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells may be used for non-domestic purposes such as landscape irrigation. 3. Street signs are to be in place, water system shall be approved and activated, pressurized irrigation system approved and activated, drainage lots constructed, fencing installed, and road base approved by the Ada County Highway District prior to applying for building permits. All development improvemerns, including fencing, micro-paths, irrigation, and landscaping shall be installed and approved prior to obtaining certificates of occupancy. A letter of credit or cash surety in the amount of 110% will be required for all fencing, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 4. Two-Hundred-fifty watt (250w) and One-Hundred watt (100w), high-pressure sodium streetlights will be required at locations designated by the Public Works Departmern. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. Street light cornractor to obtain design and permit from the Public Works Department prior commencing installations. 5. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 6. Submit "Final" letter from the Ada County Street Name Committee, approving the subdivision and street names. Make any corrections necessary to conform. Applicant's engineer will be required to submit a signed, stamped statement certifying that alt street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. 8. Coordinate fire hydrant placement with the City of Meridian's Water Deputy Fire Chief and the Public Works Department. FP-04-024 Segeland Subdivison FP.dac Mayor & City Council Hearing Date: Apri120, 2004 Page 5 of 5 9. Provide five-foot-wide sidewallcs in accordance with City Ordinance Section 12-5-2.K. Sidewalks are to provide a clear five-foot-wide (four feet if detached) walkway pathway without encroachment of mailbox structures. 10. All development shall comply with the Americans with Disabilities Act and the Fair Housing Act. 11. No building permits shall be issued within the development until a final plat has been recorded for this subdivision. RECOMMENDATION Staff recommends approval of the final plat for Sageland Subdivision with the above stated comments and conditions. FP-04-024 Sageleod Subdivision FP.doc