HomeMy WebLinkAboutService Agreement with Peak Performance for HVAC MPD
Agreement No
i~
-. Servicei'M
Expert~~
"d"oi= in dlouu, eNol 'D,,:!," C
Jay Stark
120 E. 40th. Boise, Ideho 83714
(208) 342-6813 . 1-800-572-6813' FAX (208) 345-6935
Designed especially for
/
J\ŒRDIAN POLICE
DEPARTMENT
HV AC MAINENANCE
A:\ = Service"
~ ., Experts Lee
./
120 E, 40th. Boise, Idaho 83714-6346 . (208) 342-6813 . Fax (208) 345-6935
6000 N, Government Way. Coeor d' Alene, Idaho 83815. (208) 772-5165 . Fax (208) 772-6151
Type of Agreement
Page - of-
PEAK PERFORMANCE SERVICE AGREEMENT
PRICING AND ACCEPTANCE
Customer
Meridian Police Department
Billing Address
]40] E. Watertower
Meridian Idaho 83742
Contact
Jean Moore
Fax: (208) 846-7372
TML HEATING AND AlC
Also referred to as the Service Company, agrees to furnish services in accordance with the General and
Supplemental Terms aud Conditions and each Peak Performance Maintenance Schedule.
Equipment to be Serviced
(10)
Carrier Package RoofTop Units
Maintenance Options:
Complete Cooling Maintenance on 10 Systems.$774.00 X ~_PerYear= _$774-
(Condenser Coil cleaning and pleated filters included)
Complete Heating Maintenance on 10 Systems.$695.00 X J_PerYear= _$695
(pleated filters included)
Filter Change on 10 Systems ............ .... .... ...$324.00 X 2- Per Year = $648-
(pleated filters included)
Annual Investment = $2,117.00
Per Visit Billing $529.25
The agreement is effective for one year from the time of signature.
PEAK PERFORMANCE SERVICE AGREEMENT
SUPPLEMENTAL CONDITIONS
1. This Agreement provide complete maintenance visits and/or filter change visits as
requested per year on the heating and cooling equipment.
2. Coil Cleaning..
.........CondenserCoil Included X NotIncluded~
Evaporator Coil Included ~ Not Included ~
3. This Agreement provides a 10% percent discount off parts and labor for service.
4. This Agreement provides priority service. TML will respond to the Customer's
request for emergency service before providing service to any customer who does not
have a Service Agreement.
5. Preventive Maintenance is to be performed during regular working hours (8:00am-
5:00pm Monday through Friday) unless prior arrangements are made.
6. Upon completion of each Peak Performance Inspection, TML will provide the
Customer with a comprehensive inspection report listing work performed, defects
found and corrected, and any recommended corrective action.
7. Any additional expense incurred from repairs require in excess of the scheduled
maintenance that totals $150.00 or more will require written authorization ITom the
Client or representative prior to completion of repairs.
8. TML shall maintain the Customer's equipment to keep utility and repair cost as low
as possible, while preserving equipment reliability and life. Occupant comfort will
always be a primary consideration.
9. The Customer shall operate the equipment in accordance with the manufacturer's
recommendations and promptly notify the TML of any abnormal conditions.
10. Any additional services mat are not part of this agreement, shall be billed at the
prevailing time and material rate, less the discount listed above.
11. There will be "No Overtime" charged to maintenance agreement customers.
GENERAL TERMS AND CONDmONS
1.
The service company agrees to provide a compreheusive maintenance program designed to reduce
your utility an repair costs, after any existing defects are corrected
The customer agrees to furnish safe, reasonable access to the building and covered equipment. The
customer will remove any material, fixtures, or walls so adequate access cau be gained to the
equipment
This agreement does not include the maintenance, repair, or replacement of recording or portable
instruments, electrical disconnect switches, casing or cabinets, insulation, gas lines, water lines or
non-moving parts as ductwork, vessels, boiler shells, tubes, vents, flues, grilles, tower fill or
refractory material. The Service Company shall not be required to furnish any equipment, service
or materials or to perform test, or make auy modifications that have been recommended or
required by any insurance company, governmental authority, equipment vendor or regulatory
authority, or pay any furore taxes in1posed by any governmental agency.
The Service Company shall not be liable for:
a) damage or loss resulting ftom freezing, corrosiou, electrolysis, vibration, plumbing
stoppage, failure of any utility service, low voltage condition, lightoing, single phasing,
or any other electrical abnorma1ities;
damage or loss resulting ftom negligence, faulty system design, abnse, acts of God,
malicious mischief, vandalism or improper operation of equipment by customer's
employees, agents or tenants;
damage, loss or delays resulting from fife, explosion, flooding, the elements, strikes,
labor troubles, civil commotion or any other cause beyond its control;
any accident. injury, damage, or loss to equipment, personnel, property or revenue un1ess
directly caused by its negligence;
any indirect or consequential damages such as, but not limited to, loss of revenue or loss
of use of any equipment, process or facilities;
any identification, abatement, encapsulating or removal of any hazardous material
including those containing asbestos. If any hazardous materials are detected during the
course of work, the Service Company can discontinue the work until the hazard has been
eliminated, and shall receive an e,,1ension equal to the time of delay to complete the
work. The Service Company reserves the right to be compensated for any loss due to a
delay caused by asbestos or any other hazardous material.
Uuless otherwise noted, the Service Company shall not be liable for starting and stopping
equipment, space temperature regulation, air or water balance, indoor air quality, equipment
relocation or maintenance or repair other than during normal working hours. If Customer requests
work be performed other than during normal hours, the Customer agrees to reimburse the Service
Company for additional charges.
The Service Company shall use ordinary care in performing the tasks outlined in this agreement.
No inspection shall guarantee the condition of the equipment or eliminate obsolescence and
normal wear.
The occurrence of any of the following without prior written consent of the Service Company will
constitute a default:
a) failure by the Customer to make any payment due within ten days after it becomes due
and payable;
any alterations, additions, adjustments or repairs to covered equipment, by aoyone other
than the Service Company;
Breach by Customer of any term of this Agreement. If the Service Company brings legal
action to enforce this Agreement, and is successful, it shall be entitled to recover
reasonable attorney fees and the cost of litigation in addition to any judgment for
damages.
This Agreement begins on the date of acceptance and shall remain in force for the term stated.
Thereafter, it shall be automatically renewed and shall continue in effect for successive renewal
periods of one year unless either party gives the other written notice of termination at least 30 days
before the anniversary date. With 45 days written notice, the Service Company may add or delete
equipment or services and increase or reduce the Agreement price. Customer shall have the right
to terminate if any changes are not acceptable.
This Agreement contains the entire understanding between the Service Company and the
Customer. Any modifications, amendments or changes must be in writing and signed by both
parties.
2.
3.
4.
b)
c)
d)
e)
1)
5.
6.
7.
b)
c)
8.
9.
If:.\service .... e
~Experts. =
120 E. 40th. Boise, Idaho 83714-6346 . (208) 342.6813
ROOFTOP HVAC UNIT
FAN
CONDENSER
FAN
CONDENSER
COIL
ZONE
DAMPERS
MAINTENANCE REQUIREMENTS
. INSPECT STARTER COILS AND CONTACTS
OF FAN MOTOR
. CLEAN OR CHANGE FILTERS AS REQUIRED
. CHECK OPERATING CURRENT AND
VOLTAGE OF FAN MOTORS
. PERFORM COMBUSTION AND DRAFT TEST -
ON BURNER
. LUBRICATE MOTOR BEARINGS AND
TIGHTEN ELECTRICAL CONNECTIONS
. INSPECT AND CLEAN NOZZLES
. TEST SAFETY CONTROLS FOR PROPER
OPERATION
. CHECK CONDITION OF DRIVE COUPLINGS
AND BELTS AND REPAIR OR REPLACE AS
REQUIRED
. CHECK ZONE DAMPERS FOR PROPER
OPERATION AND LUBRICATE AS REQUIRED
. CHECK CONDENSER COIL FOR DAMAGE
AND LEAKS
. CHECK OPERATING SURFACE
TEMPERATURE AND MEASURE VIBRATION
. CHECK CRANKCASE HEATER ON
COMPRESSOR FOR PROPER OPERATION
. INSPECT HIGH PRESSURE SAFETY VALVE
. CHECK CONTROLS FOR PROPER
. CHECK REFRIGERANT CHARGE AND SEQUENCE OF OPERATION
PERFORM ACID TEST
Heating & Air Conditioning
@"serviceTMMECHANICALCONTRACTOR
. M . ~ . . HEATING. AIR CONDITIONING. SHEET METAL
"". r:vnl:Jrt'S 120 E. 40th. Boise, Idaho 83714. (208) 342-6813
. CAi"". I Fax No. (208) 345-6935
*COMMERCIAL ACTION LIST*
UNIT INFORMATION:
MFG
MODEL #
SERIAL #
APPROX AGE OF UNIT
FILTER
BELT
ACTION LIST
CHECK OFF
I. CHECK REFRIGERATION CYCLE
2. CHECK SAFETY CONTROLS
3. CHECK BURNER OPERATION & FLUE ASSEMBLY
4. CHECK PILOT OPERATION
5. CHECK FOR PROPER FLAME
6. CHECK COMBUSTION AIR MOTOR: OIL Y/N
7. LOW AMBIENT CONTROL: Y/N_OK?-
8. INSPECT CONDENSATION DRAINS
9. CHECK CONDENSING MOTOR/FAN BLADES
10. CHECK ECONOMIZER
11. BELT: YES- NO_SIZE_CONDITION-
12. CHECK CONTACTOR CONDITIONS
13. CHECK WIRING CONNECTIONS
14. CHECK THERMOSTAT
15. CHECK CONDENSER! EVAPORATOR COIL IF ACCESSffiLE
16. COMPRESSOR: WORKING OK? YES_NO-
17. COMPRESSOR: AMPS_SP_HP_WB-
18. AMBIENT AIR TEMPERATURE
.,
120 E. 40th. Boise, Idaho 83714-6346 . (208) 342-6813
CONSEQUENCES
OF IMPROPER MAINTENANCE
1. INCREASED TOTAL COST OF OWNERSHIP
2. COMFORT CONDITIONS NOT MAINTAINED
3. MAINTENANCE AND REPAIR COST NOT STABILIZED
4. PREMATURE CAPITAL REPLACEMENT
5. INEFFICIENT FUEL CONSUMPTION
EXAMPLES OF INEFFICIENT FUEL CONSUMPTION
. POOR DAMPER ADJUSTMENT AND IMPROPER SEQUENCING CAN CAUSE 30-
50% UNNECESSARY HEAT LOSS
. DIRT IN AIR HANDLING SYSTEMS REDUCES FLOW EFFICIENCY AS MUCH
AS 25%
. DIRTY CONDENSER COIL RAISES CONDENSING TEMPERATURE 15° AND
CUTS OPERATING EFFICIENCY 15%
. 10% CONDENSER FAN BELT SLIPPAGE CAN CUT COOLING CAPACITY BY 5%
. SCALE BUILDUP OF .05 INCHES CAN INCREASE FUEL CONSUMPTION BY 40%
. TOO RICH FUEL/AIR MIXTURE CAN INCREASE FUEL CONSUMPTION 15%
. .1 INCH OF SCALE ON BOILER WATER SIDE CAUSES 10% HEAT LOSS
. 1/8" OF SOOT ON BOILER FIRESIDE CAUSES 30% HEAT LOSS
. DIRTY BURNER DROPS HEATING EFFICIENCY AS MUCH AS 20%
. A FAULTY 1/2 INCH STEAM TRAP CAN WASTE AS MUCH AS 20 GALLONS OF
FUEL A DAY
. OVER HEATING BY 3° AT 50° OUTSIDE AIR TEMPERATURE WASTES 17% OF
FUEL CONSUMED
Heating & Air Conditioning