Loading...
HomeMy WebLinkAboutScentsy South Campus Drainage Calculations_Page_3_Page_06Information: 6Project Project Name: SCENTSY CDC WARE 2 StormTecil Location: Trench rranrc;�i-ecrnnm-e�ie�.n�m Date: 11/11/2014 Subsurface Stonnwater Management"' Engineer StormTech RPM: MC -3500 Site Calculator System Requirements System Sizing Units Number of Chambers Required 18 each Required Storage Volume CF Number of End Caps Required 6 each Stone Porosity (Industry Standard = 40%)% Bed Size (including perimeter stone) 1,087 square feet mi Stone Above Chambers 112 inch n.)Ofeet inches Stone Required (including perimeter stone) 245 tons Stone Foundation Depth (5 inch min.)inches Volume of Excavation 292 cubic yards Average Cover over Chambers (2! incl � n1in.)inches Non -woven Filter Fabric Required (20% Safety Factor) 407 square yards Bed size controlled by WIDTH or LENGTH? Length of Isolator Row 47.8 feet Limiting WIDTH or LENGTH dimension Non -woven Isolator Row Fabric (20% Safety Factor) 83 square yards Storage Volume per Chamber 1943. CF Woven Isolator Row Fabric (20% Safety Factor) 105 square yards Storage Volume per End Cap 52.0 CF Installed Storage Volume 3,809 cubic feet Controlled by Width (Rows) - 65 4 1.98-01emm) za Maximum Width= 25 feet MAX MIN 1 3 rows of 6 chambersi J ry '_ 7- �J z t i Maximum Length = 47.8 feet 4U Maximum Width= 22.8 feet xr ,. (1143mm) -it r l v ��rl�., t�t1,��y� _ 18 - 7r(1956mm) -� 1 Inches This represents the estimated material and site work costs (US dollars) forthe pmject. Materials excluded from this estimate are conveyance pipe, pavement design, etc. It is always advisable to seek detailed construction costs from local installers. Please contact STORMTECH at 888-892-2694 for additional cost lformadon.