HomeMy WebLinkAboutRoseleaf Subdivision PP 04-001MA~~ 3 ~ 2004 t~,-- a: (lhsici -_z~ UVIEI'I~IC(72 STAFF SUMMARY mneo P~: OF ,.. ~ £, ~` " ~ PLANNING AND ZONING COMMISSION RECOMMENDATION TO CITY COUNCIL Project Name: Roseleaf Subdivision Case No(s).: AZ-04-002, P-04-00 Applicant: Centennial Development, LLC P&Z Commission Hearing Date: March 4, 2004 Recommendation: Approve with conditions (all ayes) Summary of Public Hearings: • Shawn Nickel, representing the applicant (land planner), testified in favor of the application. He provided background information, summarized the plat modifications and answered Commission questions regarding the existing residence and the common driveway lots. • David Bailey, representing the applicant (engineer), discussed the reasons for the common driveway lot design and stated it was designed in accordance with city code. He proposed an alternative design and stated a cul-de-sac layout was also explored but would reduce the amount of open space. • Anna Powell stated that the common driveway lot configuration meets "the letter but not the intent" of the ordinance and generally supported the proposed design. She stated that staff would clarify the ordinance language in the current ordinance amendment. • Other key points of discussion included the pros and cons of restricting all direct access to Locust Grove for the existing residence. Key Commission Changes to Staff Recommendation: • Added a clarification to Pre Plat Site Specific Condition #3 that the city has agreed to help the permitting of a new garage and conversion of the existing garage to living space on the Bell lot (existing residence) in the northeast comer. Added the Right to Farm Act as a note on the plat. Outstanding Issues for City Council: • During the Agency/Department comments meeting for this project, the Meridian Police Department (Chief Musser) expressed concern about the "hidden" nature of Lots 16 -19 in the center of Block 3 (see Pre Plat Special Consideration #1 on page 8 of the staff report). Site Specific Condition #2 (pg. 9) of the staffreport required a new micropath connection from the common area into this "quad" of homes to give responding officers a second point of approach/access to these four (4) homes. The P&Z Commission agreed with the applicant's proposal to simply construct a gate in the four-foot fence north of these lots rather than a micropath without a gate. However, the Commission's motion did not snecifically modifv Site Specific Condition #2. So the attached Recommendation retains the orieinal condition. It also affects the MPD condition #G 1 on page 10 of the attached Recommendation. Staff recommends the City Council and applicant re-address this issue at the Apri16 public hearing and how the MPD's concerns will be addressed. Chief Musser verbally told staff that one concern with the gate is ensuring it is not locked so as not to impede officer movement in an emergency response situation. Bollazds may be a preferred option. BEFORE THE PLANNING AND ZONING COMMISSION IN THE MATTER OF THE REQUEST FOR PRELIMINARY PLAT APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R 8 ZONE FOR ROSELEAF SUBDIVISION Case No. PP-04-001 RECOMMENDATION TO CITY COUNCIL CENTENNIAL DEVELOPMENT, LLC Applicant The property is approximately 24.45 acres in size and is located on the west side of S. Locust Grove Road, south of Tuscany Village Subdivision No. 2, in Section 30, Township 3 North, Range 1 East. 2. Tina Iest Family LTD Partnership (23.95 ac.) and Richard Bell (1 ac.) are the current property owners and both parties submitted notarized consent for the subject application. 3. The Applicant is Centennial Development, LLC. 4. The subject property is currently zoned RUT. There is, however, an application for annexation and zoning to R-8 before the City Council. The zoning of R-8 is defined within the City of Meridian Zoning and Development Ordinance Section 11-7-2. The property, which is the subject of this application, is within the Area of Impact of the City of Meridian. 6. The entire property is included within the Meridian Urban Service Planning Area as defined in the Meridian Comprehensive Plan. The Applicant proposes to develop the subject property in the following manner: A residential subdivision with 98 buildable lots and seven common/other lots. 8. There are no significant or scenic features of major importance that affect the consideration of this application. RECOMMENDATION TO CITY COUNCII, FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 1 RECOMMENDATION The Meridian Planning and Zoning Commission hereby recommends to the City Council of the City of Meridian that they approve the requested Preliminary Plat as requested by the Applicant for the property described in the application, subject to the following: A. Adopt the Special Recommendations of the Planning and Zoning Commission as follows: 1. The Preliminary Plat, revised 03-02-04 (received by the City Clerk 03-04-04), is recommended for approval. All lot and block number references in the staff report should reflect the revised plat. 2. Modify Site Specific Condition of Approval #3 (of original staff report) to add a new sentence which reads as follows: "The Planning & Zoning Commission supports a building permit for a new, detached garage on Lot 5, Block 1 and the conversion of the existing garage to living space." 3. Add a new Site Specific Condition of Approval which reads as follows: "A reference to the Right to Farm Act shall be shown on the face of the plat." B. Adopt the Comments and Recommendations of the Meridian Planning & Zoning and Engineering Departments as follows: SITE SPECIFIC CONDITIONS OF APPROVAL (PRELIMINARY PLATT 1. Provide a new, 15-foot wide micropath lot with a minimum 5-foot wide sidewalk from the common lot (Lot 1, Block 3) to the south. Said sidewalk shall be located in general alignment with the common driveway for Lots 12-15, Block 3 and shall connect with the proposed 5-foot pathway in Lot 1, Block 3. Fencing adjacent to said micropath shall comply with MCC 12-13-15-9. 2. Amend the preliminary plat to show Lot 5, Block 1 taking its public street access internal to the development (i.e. Roseleaf Street). In accordance with ACHD policy, both exisfing driveways for Lot 5, Block 1 on Locust Grove Road shall be closed. The sidewalk and perimeter fence shall be extended along the full Locust Grove Road frontage of Lot 5, Block 1 to the north property line of the subdivision. The Planning & Zonin¢ Commission supports a building~ermit for a new detached earaee on Lot 5. Block 1 and the conversion of the existine Qara¢e to livin sg nace. 3. Per Ordinance 12-13-15-9, six-foot "open vision" or four-foot solid fencing is required around the perimeter of Lot 1, Block 3 and Lot 10, Block 5. Submit a revised fencing plan with the final plat. The developer shall construct the fence prior to release of any Certificate of Occupancy within the respective phases. RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 2 4. The three (3) common driveways in Blocks 2, 3 and 4 shall be designed in accordance with MCC 12-4-14, Common Drive Design Standards. Any portion of the flag lots for Lots 16 - 19, Block 3 that is beyond the 24-foot wide driveway surface shall be landscaped. 5. Lots 15 and 20, Block 3 shall be prohibited from any vehicular access to the common driveway serving Lots 16 -19, Block 3. 6. The fencing on the common east-west lot lines between Lots 16 and 17 and between Lots 18 and 19 shall also be restricted to six-foot "open vision" or four-foot solid. 7. All azeas being counted toward the 5% open space requirement shall be free of "wet ponds" or other such nuisances. All stormwater detention facilities incorporated into the required open space aze subject to Ordinance 12-13-14 and shall be fully vegetated with grass and trees, as depicted on the submitted landscape plans. Please submit all up-to-date groundwater monitoring data to the Public Works Department for review. The initial study indicates that shallow groundwater may be a factor. All drainage areas (detention/retention basins) must be designed to ensure that water will percolate or discharge within a period of time not to exceed 24 hours for all storms up to and including a 100-year storm event. Side slopes within drainage areas shall not exceed 3:1. The project engineer should pay close attention to the results of field studies determining the geoundwater, soil type & and characteristics during the design and construction phases. The engineer shall be required to certify that the street centerline elevations are set a minimum of 3-feet above the highest established normal groundwater elevation. This is to ensure that the bottom elevation of the crawl spaces of homes is at least 1-foot above groundwater. 9. Sanitary sewer service to this site shall be via main line extensions from an existing main installed adjacent to the property. The applicant will be responsible to construct sewer mains to and through this proposed development, (to the ends of the stub streets Spicewood and Claire). Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that are required to provide service. 10. Domestic water service to this site shall be via main line extensions from mains installed adjacent to the property. The applicant will be responsible to construct water mains to and through this proposed development, (to the ends of the stub streets Spicewood and Claire). Subdivision designer to coordinate main sizing and routing with the Public Works Department. Applicant shall execute City of Meridian standard forms of easements, for any mains that aze required to provide service. 11. The applicant has not indicated who will own and operate the pressurized irrigation system within this development. Underground veaz-round pressurized irrigation must be provided to all lots within this development. The City of Meridian requires that RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 3 pressurized irrigation systems be supplied by a yeaz-round source of water. If the pressurized irrigation system within this development is to remain a private homeowners' association system, complete plans and specifications shall be reviewed by the Public Works Department as part of the development plan review process. A draft copy of the pressurized irrigation system O&M manual shall be submitted prior to plan approval. The Applicant shall be required to utilize any existing surface or well water for the primary source. If a surface or well source is not available, asingle-point connection to the culinary water system shall be required. If a single-point connection is utilized, the developer shall be responsible for the payment of assessments for the common areas prior to signature on the final plat by the City Engineer. 12. Applicant shall submit 10 copies of revised plat and landscape plans prior to the next public hearing on this application. The revised landscape plan shall include that portion of the flag lots in Block 3 which is beyond the driveway surface width. 13. A reference to the Rieht to Farm Act shall be shown on the face of the plat. STANDARD CONDITIONS OF APPROVAL (PRELIMINARY PLATT 1. All grading of the site shall be performed in conformance with MCC 11-12-3H. 2. Sidewalks shall be installed within the subdivision and on the perimeter of the subdivision pursuant to MCC 12-13-10-8. 3. Please submit with the final plat application a copy of the Ada County Street Name Committee's approval letter for the subdivision name, and the lot and block numbering. Make any corrections necessary to conform. 4. A letter of credit or cash surety in the amount of 110% will be required for all fencing, landscaping, pressurized irrigation, sanitary sewer, water, etc., prior to signature on the final plat. 5. A detailed landscape and fencing plan, in compliance with the landscape and subdivision ordinance, shall be submitted for the subdivision with the final plat application. 6. Coordinate fire hydrant placement with the City of Meridian Public Works Department. Two-hundred-fifty and one-hundred-watt, high-pressure sodium streetlights will be required at locations designated by the Public Works Department. All streetlights shall be installed at subdivider's expense. Typical locations are at street intersections and/or fire hydrants. Final design locations and quantity are determined after power designs are completed by Idaho Power Company. The street light contractor shall obtain design and permit from the Public Works Department prior commencing installations. 8. Any tree over 4" in caliper that is removed from the property shall be replaced by installing additional trees, being the equivalent number of caliper inches of trees that RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 4 were removed. Required landscaping trees will not be considered as replacement trees for those trees that have to be mitigated. 9. Any existing domestic wells and/or septic systems within this project will have to be removed from their domestic service per City Ordinance Section 9-1-4 and 9-4-8. Wells maybe used for non-domestic purposes such as landscape irrigation. 10. Compaction test results must be submitted to the Meridian Building Department for all building pads receiving engineered backfill, where footing would sit atop fill material. 11. Applicant's engineer will be required to submit a signed, stamped statement certifying that all street finish centerline elevations are set a minimum of three feet above the highest established normal groundwater elevation. C. Adopt the Recommendations of ACRD as follows: The applicant shall do one of the following regarding Locust Grove Road: a. Dedicate by donation a total of 35-feet from centerline (an additional 10-feet) of right- of-way along Locust Grove Road, and construct a minimum 5-foot wide concrete sidewalk along Locust Grove Road, located a minimum of 28-feet from the centerline of the right-of--way. b. Do not dedicate additional right-of--way, but construct a minimum 5-foot wide concrete sidewalk along Locust Grove Road, located a minimum of 28-feet from the centerline of the right-of--way, in an easement provided to the District. c. Do not dedicate additional right-of--way, but construct a minimum 5-foot wide concrete sidewalk along Locust Grove Road, located at the back edge of the existing right-of- way. Accomplish all necessary adjustments to properly accommodate existing drainage and utilities. 2. Construct all of the internal streets as 36-foot street sections within 50-feet of right- - of-way with 5-foot concrete sidewalks. 3. Provide a minimum clear distance of 21-feet (measured back-of--curb to back-of- curb) on both sides of any landscape islands. 4. Provide 64-feet ofright-of--way for Claymont Street to accommodate the landscape island. 5. At a minimum the applicant shall construct one landscape island on Chatsworth Street located between Brigham Avenue and Bridekirk Avenue, and one landscape island on Roseleaf Street between Brigham Avenue and Bridekirk Avenue. The islands shall be constructed a minimum of 4-feet wide (maximum 12-feet wide) to total a minimum of a 100-square foot area. Dedicate the additional right-of--way necessary to accommodate the landscape islands. RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 5 6. Any landscape islands or medians shall be owned and maintained by the homeowner's association. Notes of this are required on the final plat. Pave the existing north residential driveway (located approximately 25-feet south of the north property line) its full width and at least 30-feet into the site beyond the edge of pavement of the roadway and install pavement tapers with 15-foot radii abutting the existing roadway edge. 8. Construct Claymont Street, the main entrance, to intersect Locust Grove Road approximately 285-feet south of the north property line (measured property line to centerline). 9. Construct Ascaino Avenue as a stub street connection to the north property line to connect to Tuscany Village Subdivision. Align Ascaino Avenue with the stub street from Tuscany Village Subdivision. 10. Construct Ascaino Avenue as a stub street to the south property line located approximately 670-feet (measured centerline to centerline) west of Locust Grove Road. Install a sign at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". 11. Construct Chatsworth Street as a stub street to the west property line located approximately 130-feet (measured property line to centerline) north of the south property line. Install a sign at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE". 12. Other than the access that is specifically approved with this application, direct lot access to Locust Grove Road is prohibited and shall be noted on the final plat. 13. Comply with all Standard Conditions of Approval. ACHD Standard Conditions of Approval 1. Any existing irrigation facilities shall be relocated outside of the right-of--way.. 2. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 3. Replace any existing damaged curb, gutter and sidewallc and any that maybe damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 4. Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District's Utility Coordinator at 387- 6258 (with file numbers) for details. RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 6 5. All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all applicable ACRD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 6. The applicant shall submit revised plans for staff approval, prior to issuance of building permit (or other required permits), which incorporates any required design changes. 7. Construction, use and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval for occupancy. Payment of applicable road impact fees are required prior to building construction in accordance with Ordinance #198, also known as Ada County Highway District Road Impact Fee Ordinance. 9. It is the responsibility of the applicant to verify all existing utilities within the right- of-way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1-800-342-1585) at least two full business days prior to breaking ground within ACRD right-of--way. The applicant shall contact ACRD Traffic Operations 387-6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 10. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the applicant to obtain written confirmation of any change from the Ada County Highway District. 11. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest advises the Highway District of its intent to change the planned use of the subject propertyunless awaiver/dariance of said requirements or other legal relief is granted pursuant to the law in effect at the time the change in use is sought. D. Adopt the Meridian Fire Department Recommendations as follows: One and two fanuly dwellings will require afire-flow of 1,000 gallons per minute available for duration of 2 hours to service the entire project.. Fire hydrants shall be placed an average of 400' apart. International Fire Code Appendix D RECOMIvIENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 CONIMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 7 2. Acceptance of the water supply for fire protection will be by the Meridian Water Department. 3. Final Approval of the fire hydrant locations shall be by the Meridian Fire Department. a. Fire Hydrants shall have the 4 ''/z" outlet face the main street or parking lot aisle. b. The Fire hydrant shall not face a street which does not have addresses on it. c. Fire hydrant mazkers shall be provided per Public Works spec. d. Locations with fire hydrants shall have the curb painted red 10' to each side of the hydrant location. e. Fire Hydrants shall be placed on corners. f. Fire hydrants shall not have any vertical obstructions to outlets within 10'. 4. The phasing plan may require that any roadway greater than 150' in length that is not provided with an outlet shall be required to have an approved turn azound. 5. All entrance and internal roads shall have a fuming radius of 28' inside and 48' outside. 6. Insure that all yet undeveloped parcels are maintained free of combustible vegetation. 7. Operational fire hydrants and temporary or permanent street signs are required before combustible construction begins. 8. A minimum of two points of access will be required for any portion of the project, which serves more than 50 homes. This shall be measured off of the center line of the street. 9. Building setbacks shall be per the Building Code for one and two story construction. 10. The roadways shall be built to Ada County Highway Standards and shall have a cleaz driving surface, available at all times, which is 20' wide. Streets with less than a 29' street width shall have no pazking. Streets with less than 33' shall have pazking only on one side. 11. Fire lanes and streets shall have a vertical cleazance of 13'6". This includes mature landscaping. 12. The proposed 98-lot subdivision with an estimated 2.9 residents per household would have a total estimated population of 284 residents at build out. The Meridian Fire Department has experienced 2069 responses in the year 2000 and 2251 calls for service in 2001. According to a report completed by Fire & Emergency Services RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 8 Consulting Crroup in February of 2000 our requests for service are projected to reach 2800 in the year 2005 and 3800 by the year 2010. 13. The proposed project lies outside the five-minute response zone goal. Achievement of this goal is subject to budgetary constraints and is intended to enhance the probability of a favorable outcome on a request for Basic Life Support. The budget constraints are typically defined as capital outlay for facilities that are located within 1.5 miles from a given location and sufficient operational funds to staff the facilities. 14. The fire department requests that any fixture signalization installed as the result of the development of this project be equipped with Cpticom Sensors to ensure a safe and efficient response by fire and emergency medical service vehicles. This cost of this installation is to be borne by the developer. E. Adopt the Recommendations of the Central District Health Department as follows: 1. This proposal can be approved for central sewage & central water after written approval from appropriate entities is submitted. 2. The Applicant's central sewage and central water plans must be submitted to and approved by the Idaho Department of Health & Welfare, Division of Environmental Quality. 3. Run-off is not to create a mosquito breeding problem. 4. Stormwater shall be pretreated through a grassy swale prior to discharge to the subsurface to prevent impact to groundwater and surface water quality. 5. The Engineers and architects involved with the design of the subject project shall obtain current best management practices for stormwater disposal and design a stormwater management system that prevents groundwater and surface water degradation. F. Adopt the Recommendations of Nampa Meridian Irrigation District as follows: 1. Applicant shall apply for a land use change application prior to final platting. 2. All laterals and waste ways must be protected. 3. All municipal surface drainage must be retained on site. If any surface drainage leaves the site, the Nampa & Meridian Irrigation District must review drainage plans. 4. The Developer must comply with Idaho Code 31-3805. RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 9 5. NMID recommends that irrigation water be made available to all developments within the Nampa & Meridian Irrigation District. G. Adopt the Recommendations of the Meridian Police Department as follows: Lots 16 through 19 of Block 3 create residences that will be isolated from their surrounding neighbors. Such areas have an increased crime potential. Prior to the next public hearing, the applicant shall work with the Police Chief and/or Planning Staff to revise the plat/site plan such that the houses/dwelling units in the general area aze oriented toward one another and encourage interaction between more neighbors. H. Adopt the Recommendations of the Sanitary Services Company as follows: 1. In accordance with MCC 4-1-11.B.4, the trash receptacles for Lots 16-19, Block 3 shall be located no more than five (5) feet behind the Chatsworth Street sidewalk. SSC will not provide trash pick-up services utilizing the common driveway. The trash receptacle(s) shall not cause a nuisance and shall be enclosed. RECOMMENDATION TO CITY COUNCIL FOR APPROVAL OF 98 BUILDABLE LOTS AND 7 COMMON/OTHER LOTS ON 24.45 ACRES IN AN R-8 ZONE, BY CENTENNIAL DEVELOPMENT, LLC - PP-04-001 -Page 10