Loading...
Brighton Response to ACHDBRIGHTON CORPORATION December 5, 2018 Mindy Wallace, AICP, Planner III Ada County Highway District 3775 N. Adams St. Garden City, ID 83714 SUBJECT. TM Crossing Expansion (MER18-0123 I H-2018-01220 AZ) Dear Ms. Wallace, Your staff report dated November 16, 2018 concerning the referenced City of Meridian application contains Site Specific Condition of Approval B.3 which prohibits gating the Fire Department -required emergency access within unimproved -and -never -used Verbena Drive right-of-way. The City's adopted TM Crossing Findings of Fact, Conclusions of Law and Decision & Order, Page 11, (Addendum No.1) references "an opportunity for an emergency access point at the east boundary of the site from...a 25-32 (varies) foot public right-of-way, W. Verbena Drive ... a portion of which has not been improved. If emergency access is provided in this location, the access road would need to be improved per Fire Department standards. " That statement, from the analysis section of the Meridian staff report, was in response to Fire Department Condition 3.26 (Staff Report, Page 37) citing the Fire Code requirement for "two separate and approved fire apparatus access roads... " when gross building area in the project exceeds 62,000 square feet. TM Crossing has exceeded that threshold. Thus, the use of the unimproved Verbena right-of-way for a secondary, emergency fire access has been required by the City within the area depicted below. 12601 W. Explorer Drive Suite 200 Boise, Idaho 83713 www.brightoncorp.com p. 208-378-4000 f. 208-377-8962 The Condition B.3 prohibition of gating within the right-of-way assumes the street has been improved. The emergency access portion of the Verbena Drive ROW never been improved. It has been used as pasture and gated since the subdivision was platted and developed in the 1970's. The gate located on the east side of the pasture, at the west end of the "unpaved ROW" within the ROW (graphic above), is shown below in a photograph taken August 14, 2018. It has since been replaced by wider gate in compliance with "Fire Department standards. " The use of the heretofore unimproved Verbena right-of-way for a gated fire access is temporary; it will be vacated when a public street from TM Crossing is extended to Franklin Road as illustrated in the graphic on the following page. Proposed Actions First – We request ACHD's "interim" approval of the gating of the City of Meridian Fire Department - required fire access within the unimproved Verbena Drive right-of-way as proposed in the TM Crossing Expansion application. In support of that request, we are providing Addendum No. 2, a seven -page Google Earth photographic history of the site, with eleven images taken between May 5, 1992 and July 16, 2018. The constant: That portion of the Verbena Drive right-of-way has never been improved—and has been gated pasture virtually every day since the Primrose Subdivision was platted and the one -acre lots were improved. The sole "improvement" exception is noted in the Addendum No. 2, Page 7, photo image dated 06.11.17 which was taken soon after a City of Meridian water main was installed within the right-of-way Second – We request that the "interim" facility be granted by license agreement to terminate with the construction of a roadway from TM Crossing to Franklin Road. At that point, the emergency fire access can be abandoned and the right-of-way returned to its current unmaintained condition, or be landscaped by a second license agreement as a 25 -foot City of Meridian landscape buffer which is required between commercial and residential uses. 2 Please let us know what more we can do to facilitate this City of Meridian requirement. Resp fully Michael D. Wardle Director of Planning k, '"Er",000 TEN, M9. I L E . 0..c .'^-_.. t �t to to re - 0 40 40, ti of f«, wo Ica W eta 14:4, tE4o f. i C Wy Ui ow77.. iROADWAY CONNECTION j FROM TM CROSSING TO FRANKLIN RD APPROX THREE YEARS WALTMAN VERBENA 3 A �,, tn DENDUM N0.7"! Density Employment designated areas as well as the proposed Commercial designation. However, Medium High Density areas are anticipated to have residential (R-8 or R-15) zoning. Because the applicant proposes a Commercial designation for the entire site, no residential zoning is proposed. The residential designated area consists of approximately 8.5 acres at the northeast corner of the site. Hours of Operation: Business hours of operation in the C -G zoning district are limited from 6:00 am to 11 pm when the property abuts a residential use or district, per UDC 11 -2B -3A.4. There are existing residences along the east boundary of this site. Staff recommends that hours of operation of businesses along that boundary be restricted accordingly through the DA. Sign: A Welcome to Meridian monument sign is designated on this property visible from the I-84 off -ramp to Ten Mile Road. Staff is recommending a DA provision that the developer construct a sign accordingly and coordinate with staff on the location and design. PRELIMINARY PLAT (PP): A preliminary plat is proposed that consists of 50 commercial building lots and 4 common/other lots on 75.5 acres of land for TM Crossing Subdivision. The preliminary plat is proposed to develop in two phases (see Exhibit A. 4). Although an abundance of lots are proposed, staff recognizes this is because future users/owners are unknown making the ultimate size and configuration of lots impossible to know at this time. The proposed plat will allow for a future reduction in lots or property boundary adjustments as needed. As noted above in Section VII, the proposed street layout is not entirely consistent with the transportation system map contained in the TMISAP. Staff recommends that the applicant revise the preliminary plat in accord with the provisions listed in Exhibit B, 1.1.1., prior to the City Council hearing. Dimensional Standards: Staff has reviewed the proposed plat for conformance with the dimensional standards of the C -G zoning district and found it to be in compliance with those standards. Future development of the property shall comply with these standards. Cross-Access/Parking: A note is depicted on the preliminary plat that grants cross- access/parking to all lots within the subdivision. Access: Access to this site is proposed via an off-site access to Ten Mile Road north of the site; no other access is available to the site at this time. ACHD policy restricts the amount of traffic allowed on a collector roadway with only one public street access in and out of the site to 3,000 vehicle trips per day. Depending on the number of vehicle trips per day, only one user or phase may be allowed until secondary access can be obtained (see ACHD comments in Exhibit B). Additionally, the Fire Department requires commercial buildings or facilities having a gross building area of more than 62,000 square feet to be provided with two separate and approved fire apparatus access roads separated by one half of the maximum overall diagonal dimension of the property or area to be served, measured in a straight line between accesses as set forth in International Fire Code Appendix D104.2. An exception is allowed for projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road and all buildings are equipped throughout with approved. automatic sprinkler systems (remoteness required). There may be an opportunity for an emergency access point at the east boundary of this site from Primrose Subdivision. Currently, there is a 25-32 (varies) foot public right-of-way, W. Verbena Drive, existing at the east boundary of this site - a portion of which has not been improved. If 1 emergency access is provided in this location, the access road would need to be improved per Fire Department standards. TM Crossing CPAM-12-001; AZ -12-005; PP -12-003 PAGE 1 I N O z z W 0 to V. qgal ° d � —,sem 96/ . I `N l33HVdl q)i � NOISNtldX3 ONISS021O W1 � F8 OG k o 1 + r JJ Google Earth 'At OA OtZr :91 -WP Google t� P. I�W i FF I�W