Loading...
PZ - Revised Staff Report1 Charlene Way From:Sonya Allen Sent:Wednesday, October 18, 2017 1:01 PM To:Barbara Shiffer; C.Jay Coles; Charlene Way; Machelle Hill Cc:trevor@tgirealestate.com Subject:Linder MIxed Use REVISED Staff Report Attachments:Linder Mixed Use - AZ, RZ H-2017-0095 Staff Recommendation to Commission REVISED.pdf I’ve revised the staff report to include the commercial building elevations submitted by the applicant; please update the file. Thanks, Sonya Allen | Associate City Planner City of Meridian | Community Development Department 33 E. Broadway Ave., Ste. 102, Meridian, Idaho 83642 Phone: 208-884-5533|Direct: 208-489-0578|Fax: 208-489-0578 Built for Business, Designed for Living All e-mail messages sent to or received by City of Meridian e-mail accounts are subject to the Idaho law, in regards to both release and retention, and may be released upon request, unless exempt from disclosure by law. Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 1 STAFF REPORT Hearing Date: October 19, 2017 TO: Planning & Zoning Commission FROM: Sonya Allen, Associate City Planner 208-884-5533 Bruce Freckleton, Development Services Manager 208-887-2211 SUBJECT: Linder Mixed Use – AZ, RZ (H-2017-0095) I. SUMMARY DESCRIPTION OF APPLICANT’S REQUEST The applicant, Trevor Gasser, submitted an application for Annexation and Zoning (AZ) of 5 acres of land with C-C (1.59 acres) and R-15 (3.41 acres) zoning districts; and Rezone (RZ) of 3.36 acres of land from the L-O to the R-15 (1.43 acres) and C-C (1.93 acres) zoning districts. See Section IX of the staff report for more information. II. SUMMARY RECOMMENDATION Staff recommends approval of the proposed AZ and RZ applications in accord with the conditions of approval in Exhibit B and the Findings of Fact and Conclusions of Law in Exhibit D. III. PROPOSED MOTION Approval After considering all staff, applicant and public testimony, I move to recommend approval to the City Council of File Number H-2017-0095, as presented in the staff report for the hearing date of October 19, 2017, with the following modifications: (Add any proposed modifications). Denial After considering all staff, applicant and public testimony, I move to recommend denial to the City Council of File Number H-2017-0095, as presented during the hearing on October 19, 2017, for the following reasons: (You should state specific reasons for denial) Continuance I move to continue File Number H-2017-0095 to the hearing date of (insert continued hearing date here) for the following reason(s): (You should state specific reason(s) for continuance.) IV. APPLICATION AND PROPERTY FACTS A. Site Address/Location: The site is located at 5940 & 5960 N. Linder Road, in the northwest ¼ of Section 25, Township 4 North, Range 1 West. (Parcel #’s: S0425233700, S0425233810, and S0425233880) B. Owner(s): Archie Douglas Stewart and Kelle Watkins 5960 N. Linder Rd. Meridian, ID 83642 Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 2 C. Applicant: Trevor Gasser 74 E. 500 S. #200 Bountiful, UT 84010 D. Representative: Trevor Gasser, TMEG Properties, LLC 74 E. 500 S. #200 Bountiful, UT 84010 E. Applicant’s Statement/Justification: Please see applicant’s narrative for this information. V. PROCESS FACTS A. The subject application is for annexation & zoning and rezone. A public hearing is required before the Planning & Zoning Commission and City Council on these applications, consistent with Meridian City Code Title 11, Chapter 5. B. Newspaper notifications published on: September 29, 2017 C. Radius notices mailed to properties within 300 feet on: September 25, 2017 D. Applicant posted notice on site(s) on: October 9, 2017 VI. LAND USE A. Existing Land Use(s) and Zoning: This site consists of rural residential properties with two existing homes and accessory outbuildings, zoned RUT in Ada County. B. Character of Surrounding Area and Adjacent Land Use and Zoning: 1. North: Vacant/undeveloped property, zoned RUT in Ada County 2. East: Single-family residential homes in Paramount Subdivision, zoned R-8 3. South: Offices and vacant/undeveloped land, zoned L-O 4. West: N. Linder Road and single-family residential homes in Lochsa Falls Subdivision, zoned R-8 C. History of Previous Actions: The L-O zoned portion of this site was annexed into the City in 2003 (AZ-03-006) with the Paramount development. A development agreement was required as a provision of annexation, recorded as Instrument #103137116. Subsequent addendums to the agreement were approved as follows:  1st addendum (MDA-08-001, Inst. #108108427)  2nd addendum (H-2015-0022, Inst. #2016-005060)  3rd addendum (H-2016-0104, Inst. #2017-003462)  4th addendum (H-2017-0064, Inst. #2017-066043) D. Utilities: 1. Public Works: a. Location of sewer: A sanitary sewer main intended to provide service to the subject site currently exists in S. Linder Road, approximately 575-feet south of the southwest corner of the subject site. b. Location of water: A water main intended to provide service to the subject site currently exists in S. Linder Road. Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 3 c. Issues or concerns: None E. Physical Features: 1. Canals/Ditches Irrigation: None 2. Hazards: Staff is not aware of any hazards that exist on this property. 3. Flood Plain: This site is not located in the Meridian Floodplain Overlay District. VII. COMPREHENSIVE PLAN POLICIES AND GOALS The northern 5-acre portion of the subject property is designated Mixed Use – Community (MU-C) and the southern 3.86-acre property is designated Mixed Use – Neighborhood (MU-N) on the Future Land Use Map (FLUM) contained in the Comprehensive Plan. MU-C: The purpose of the MU-C designation is to allocate areas where community-serving uses and dwellings are seamlessly integrated into the urban fabric. The intent is to integrate a variety of uses, including residential, and to avoid mainly single-use and strip commercial type buildings. Goods and services in these areas tend to be of the variety that people will mainly travel by car to, but also walk or bike to (up to 3 or 4 miles). Employment opportunities for those living in and around the neighborhood are encouraged. Developments are encouraged to be designed according to the conceptual MU-C plan depicted as Figure 3-3 in the Comprehensive Plan below. Developments should have a mix of at least 3 land use types [i.e. commercial (includes retail, restaurants, etc.), office, residential, civic (includes public open space, parks, entertainment venues, etc.), and industrial]; residential uses should comprise a minimum of 20% of the development area at densities ranging from 6 to 15 units/acre; non-residential buildings should be proportional to and blend in with adjacent residential buildings; vertically integrated structures are encouraged; supportive and proportional public and/or quasi-public spaces and places including but not limited to parks, plazas, outdoor gathering areas, open space, libraries, and schools that comprise a minimum of 5% of the development area are required. MU-N: The purpose of the MU-N designation is to assign areas where neighborhood-serving uses and dwellings are seamlessly integrated into the urban fabric. The intent is to avoid predominately single-use developments by incorporating a variety of uses. Land uses in these areas should be primarily residential with supporting non-residential services. Non-residential uses in these areas tend to be smaller scale and provide a good or service that people typically do not travel far for Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 4 (approximately one mile) and need regularly. Employment opportunities for those living in the neighborhood are encouraged. Connectivity and access between the non-residential and residential land uses is particularly critical in MU-N areas. Tree-lined narrow streets are encouraged. Developments are encouraged to be designed according to the conceptual MU-N plan depicted as Figure 3-1 in the Comprehensive Plan below. See pages 24-27 of the Comprehensive Plan for more information. In reviewing development applications, the following items will be considered in all Mixed Use areas: (Staff’s analysis in italics) • Residential densities should be a minimum of six dwellings/acre. A residential density of 13.5 units/acre is proposed. • Where feasible, higher density and/or multi-family residential development will be encouraged, especially for projects with the potential to serve as employment destination centers and when the project is adjacent to US 20/26, SH-55, SH-16 or SH-69. Multi-family and townhouse dwellings are proposed and the site is near US 20/26 (Chinden). • A conceptual site plan for the entire mixed-use area should be included in the application. A concept site plan for the entire development area is proposed (see Exhibit A.2). • In developments where multiple commercial and/or office buildings are proposed (not residential), the buildings should be arranged to create some form of common, usable area, such as a plaza or green space. The concept plan for the commercial area does not include common usable area; staff recommends the plan is revised accordingly. • The site plan should depict a transitional use and/or landscaped buffering between commercial and existing low- or medium-density residential development. Two-story townhomes are proposed adjacent to existing medium density residential uses, which provides a transitional use to the multi-family development and commercial uses to the west. • A mixed-use project should include at least three types of land uses. Exceptions may be granted for smaller sites on a case-by-case basis. The proposed development consists of commercial and residential uses; because the site is fairly small, staff is not recommending a third land use type is provided. Further, because this property is part of a larger mixed-use area, additional land use types should be provided within the overall designation. Office uses exist abutting the site to the south. Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 5 • Community-serving facilities such as hospitals, churches, schools, parks, daycares, civic buildings, or public safety facilities are expected in larger mixed-use developments. Because this is a smaller mixed-use development, staff does not recommend these types of facilities are required on this site. A school exists within a ¼ mile to the south of this site. • Supportive and proportional public and/or quasi-public spaces and places including but not limited to parks, plazas, outdoor gathering areas, open space, libraries, and schools are expected; outdoor seating areas at restaurants do not count. The concept plan does not depict these spaces/places. • All mixed-use projects should be directly accessible to neighborhoods within the section by both vehicles and pedestrians. There are no direct pedestrian or vehicular connections to this site from the adjacent Paramount Subdivision development; however, there will be between the commercial and residential uses within the proposed development and to the future developments to the north and south of this site. • Street sections consistent with the Ada County Highway District Master Street Map are required within the Unified Development Code. No public streets are proposed within this development. • Because of the existing small lots within Old Town, development is not subject to the Mixed- Use standards listed herein. The proposed development is not within Old Town. In reviewing development applications, the following items will be considered in MU-N areas: • Development should comply with the items listed for development in all Mixed-Use areas. See above. • Residential uses should comprise a minimum of 40% of the development area at densities ranging from six to 12 units/acre. Residential uses comprise approximately 60% of the development area at a density of 13.5+/- units/acre. • Non-residential buildings should be proportional to and blend in with residential buildings. Conceptual elevations were not submitted for the commercial buildings; elevations submitted in the future for commercial buildings should be consistent with this requirement. • Unless a structure contains a mix of both residential and office, or residential and commercial land uses, maximum building size should be limited to a 20,000 square-foot building footprint. For the development of public school sites, the maximum building size does not apply. The maximum building footprint of commercial buildings in the MU-N designated area should be limited to 20,000 square feet. • Supportive and proportional public and/or quasi-public spaces and places such as parks, plazas, outdoor gathering areas, open space, libraries, and schools should comprise a minimum of 10% of the development area. Outdoor seating areas at restaurants do not count towards this requirement. The concept plan does not depict these spaces/places. • Where the development proposes public and quasi-public uses to support the development above the minimum 10%, the developer may be eligible for additional residential densities and/or an increase to the maximum building footprint. In reviewing development applications, the following items will be considered in MU-C areas: • Development should comply with the general guidelines for development in all Mixed-Use areas. See above. • All developments should have a mix of at least three land use types. The applicant is only proposing two types of land uses; staff is not recommending a third is provided due to the smaller Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 6 size of this site and the adjacent office uses to the south which provide a third land use type is nearby. • Residential uses should comprise a minimum of 20% of the development area at densities ranging from 6 to 15 units/acre. Residential uses comprise approximately 60% of the site at a density of 13.5+/- units/acre. • Non-residential buildings should be proportional to and blend in with adjacent residential buildings. Conceptual elevations were not submitted for the commercial buildings; elevations submitted in the future for commercial buildings should be consistent with this requirement. • Vertically integrated structures are encouraged. • Unless a structure contains a mix of both residential and office, or residential and commercial land uses, maximum building size should be limited to a 30,000 square-foot building footprint. For community grocery stores, the maximum building size should be limited to a 60,000-square foot building footprint. For the development of public school sites, the maximum building size does not apply. The maximum building footprint of commercial buildings in the MU-C designated area should be limited to 30,000 square feet. • Supportive and proportional public and/or quasi-public spaces and places including but not limited to parks, plazas, outdoor gathering areas, open space, libraries, and schools that comprise a minimum of 5% of the development area are required. Outdoor seating areas at restaurants do not count towards this requirement. The concept plan does not depict these spaces/places. • Where the development proposes public and quasi-public uses to support the development above the minimum 5%, the developer may be eligible for additional residential densities and/or an increase to the maximum building footprint. The applicant proposes to develop 3+/- acres of the site along the frontage of N. Linder Road with commercial retail uses and 5+/- acres at the rear of the property with multi-family (apartments) and townhome uses consisting of a total of 113 dwelling units. Approximately 60% of the site is proposed to develop with residential uses at a density of 13.5 units per acre consistent with that desired in MU- C and MU-N designated areas. Because there are no supportive public and/or quasi-public spaces or places proposed as required in mixed use designated areas, Staff recommends that prior to the City Council meeting, the concept plan is revised to rearrange the commercial buildings to create some form of common, usable area, such as a plaza, outdoor gathering area or green space that comprises a minimum of 10% of the development area. Staff finds the following Comprehensive Plan policies to be applicable to this application and apply to the proposed use of this property (staff analysis in italics): • “Support a variety of residential categories (low-, medium-, medium-high and high-density single-family, multi-family, townhouses, duplexes, apartments, condominiums, etc.) for the purpose of providing the City with a range of affordable housing opportunities.” (3.07.01E) The proposed multi-family and townhouse development will contribute to the variety of residential categories that currently exist in this area (i.e. low and medium density). Staff is unaware of how “affordable” the units will be. • “Provide housing options close to employment and shopping centers.” (3.07.02D) Because of its location in close proximity to future mixed-use commercial, shopping and employment centers, this property is ideal for providing higher density housing options. Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 7 • “Locate high-density development, where possible, near open space corridors or other permanent major open space and park facilities, Old Town, and near major access thoroughfares.” (3.07.02N) The proposed multi-family and townhouse development is located in close proximity to major access thoroughfares (i.e. N. Linder Road and SH 20/26/Chinden Blvd. A segment of the City’s regional pathway system is also designated along the frontage of this site adjacent to N. Linder Road. • “Reduce the number of existing access points onto arterial streets by using methods such as cross-access agreements, access management, and frontage/backage roads.” (3.03.02N) A frontage road is proposed on the concept plan which separates the commercial from the residential portions of the development and provides for cross-access to the north and south to reduce access points on Linder Road. • “Locate small-scale neighborhood commercial areas within planned residential developments as part of the development plan.” (3.05.01E) The concept plan proposes small-scale commercial retail uses adjacent to a multi-family development and townhomes. • “Protect existing residential properties from incompatible land use development on adjacent parcels.” (3.06.01F) Townhomes are proposed adjacent to the medium density residential uses at the east boundary of the site which should be compatible use-wise since they are both residential in nature and not a high density. • “Develop pathways to connect Meridian with Boise, Nampa, Kuna and Eagle.” (6.01.02C) The City’s multi-use pathway system, a segment of which is proposed along the frontage of this site on N. Linder Road, will eventually connect Meridian with adjacent cities. • “Require all new and reconstructed parking lots to provide landscaping in internal islands and along streets.” (2.01.04B) Landscaping is required to be provided in accord with UDC standards with development of the site. • “Require screening and buffering of commercial and industrial properties to residential use with transitional zoning (3.06.01E). The proposed townhomes within the R-15 zoning district will provide a transitional buffer to the proposed multi-family development and commercial uses to the west. • “Permit new development only where urban services can be reasonably provided at the time of final approval and development is contiguous to the City.” (3.01.01F) This property is contiguous to land that has already been annexed into the City. Urban services can be provided to this property upon development. • “Require landscape street buffers for new development along all entryway corridors.” (2.01.02E) A 35-foot wide landscaped street buffer is required along N. Linder Road, an entryway corridor, with development of the site. • “Consider the adopted COMPASS regional long-range transportation plan in all land-use decisions.” (3.03.02G) Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 8 See the COMPASS development review letter in the project file. • “Cluster new community commercial areas on arterials or collectors near residential areas in such a way as to complement adjoining residential areas.” The neighborhood/community commercial area is proposed adjacent to N. Linder Road, an arterial street, which will complement adjoining residential uses. VIII. UNIFIED DEVELOPMENT CODE (UDC) A. Purpose Statement of Zoning Districts: Residential: The purpose of the residential districts is to provide for a range of housing opportunities consistent with the Meridian Comprehensive Plan. Residential districts are distinguished by the allowable density of dwelling units per acre and corresponding housing types that can be accommodated within the density range (UDC 11-2A-1). Commercial: The purpose of the commercial districts is to provide for the retail and service needs of the community in accord with the Meridian Comprehensive Plan. Six districts are designated which differ in the size and scale of commercial structures accommodated in the district, the scale and mix of allowed commercial uses, and the location of the district in proximity to streets and highways (UDC 11-2B-1). Allowed uses in the C-C district consist of a larger scale and broader mix of retail, office, and service uses and are typically have access to arterial streets or non- residential collector streets. B. Schedule of Use: UDC Table 11-2A-2 lists the principal permitted (P), accessory (A), conditional (C), and prohibited (-) uses in the proposed R-15 zoning district. Any use not explicitly listed is prohibited. Townhomes are listed as a principle permitted use and a multi-family development is listed as a conditional use and in the R-15 district; compliance with the specific use standards listed in UDC 11-4-3-27 is required for multi-family developments. [Note: Townhomes are required to be on individual properties (i.e. a subdivision of property is required), otherwise they are considered multi-family.] UDC Table 11-2B-2 lists the principal permitted (P), accessory (A), conditional (C), and prohibited (-) uses in the proposed C-C zoning district. Retail stores and restaurants are listed as principle permitted uses in the C-C zoning district. C. Dimensional Standards: Development of the site should be consistent with the dimensional standards listed in UDC Table 11-2A-7 for the R-15 zoning district; and Table 11-2B-3 for the C- C zoning district. D. Landscaping: Landscaping is required within parking areas in accordance with the standards listed in UDC 11-3B-8C; within street buffers in accord with UDC 11-3B-7C; and within common areas and along street-facing elevations in accord with UDC 11-3G-3 and 11-4-3-27F. Street buffers and buffers to residential uses are required as set forth in UDC Table 11-2B-3. E. Open Space & Site Amenities: Open space & site amenities are required within the development in accord with the standards listed in UDC 11-3G-3 and the specific use standards listed in UDC 11-4-3-27. F. Off-Street Parking: Off-street parking is required in accord with UDC Table 11-3C-6 for townhome and multifamily dwellings; and UDC 11-3C-6B for non-residential uses. Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 9 G. Structure and Site Design Standards: The proposed townhomes, multi-family and commercial structures must comply with the design standards listed in UDC 11-3A-19 and the Architectural Standards Manual. IX. ANALYSIS Analysis of Facts Leading to Staff Recommendation: The applicant proposes to annex & zone 5 acres of land with C-C (1.59 acres) and R-15 (3.41 acres) zoning districts. A rezone of 3.36 acres of land is also requested from the L-O to the R-15 (1.43 acres) and C-C (1.93 acres) zoning districts. The applicant has submitted a conceptual development plan, included in Exhibit A.2, that depicts (4) multi-family structures and (2) townhome structures containing a total of 113 dwelling units, a clubhouse with a fitness center, an open grassy area over 50’ x 100’ in area, a sports court and (3) 1+/- acre commercial pad sites. The concept plan depicts one vehicular access via N. Linder Road at the south boundary of the site and a north/south drive-aisle that serves as a frontage road to N. Linder Road that stubs to the north and south property lines for interconnectivity with adjacent developments in accord with UDC 11-3A-3. One vehicular access is proposed from the driveway for the multi-family portion of the development with a stub driveway to the north for future interconnectivity. A pedestrian pathway is proposed between the multi-family and commercial developments. Conceptual building elevations were submitted for the multi-family structures that consist of 3- stories and the townhome structures that consist of 2-stories with varying material types and colors. Concept elevations were also submitted for the commercial structures that are all 1 story in height; one is shown as a stand-alone building while two are shown to be in “strip” configurations. In the MU-C designated area, strip building configurations are not desired and the structures are required to be proportional to and blend in with the residential structures. All structures are required to comply with the design standards in UDC 11-3A-19 and the Architectural Standards Manual. The legal descriptions submitted with the subject annexation and rezone applications, are included in Exhibit C, and show the boundaries of the properties proposed to be annexed and rezoned. The property proposed to be annexed is contiguous to land that has been annexed into the City and is within the Area of City Impact boundary. The City may require a development agreement (DA) in conjunction with an annexation or rezone pursuant to Idaho Code section 67-6511A. In order to ensure the site develops as proposed and recommended by staff with this application, staff recommends a DA is required as a provision of the proposed annexation and rezone with the provisions included in Exhibit B. X. EXHIBITS A. Drawings/Other 1. Vicinity/Zoning Map 2. Proposed Conceptual Development Plan (dated: 8/22/17) 3. Proposed Conceptual Building Elevation Photos of Multi-Family, Townhouse and Commercial Structures B. Agency & Department Comments C. Legal Description & Exhibit Map for Annexation & Zoning and Rezone Boundaries Linder Mixed Use – AZ, RZ H-2017-0095 PAGE 10 D. Required Findings from Unified Development Code Exhibit A.1: Zoning/Aerial Map - 2 - Exhibit A.2: Proposed Site Plan (dated: 8/22/17) - 3 - Exhibit A.3: Proposed Conceptual Building Elevation Photos of Multi-Family, Townhouse and Commercial Structures MULTI-FAMILY - 4 - TOWNHOMES - 5 - - 6 - EXHIBIT B - AGENCY & DEPARTMENT COMMENTS 1. PLANNING DEPARTMENT 1.1.1 A Development Agreement (DA) is required as a provision of annexation and rezone of this property. Prior to approval of the annexation and rezone ordinances, a DA shall be entered into between the City of Meridian, the property owner(s) at the time of annexation/rezone ordinance adoption, and the developer. Currently, a fee of $303.00 shall be paid by the applicant to the Planning Division prior to commencement of the DA. The DA shall be signed by the property owner and returned to the Planning Division within six (6) months of the City Council granting annexation. The DA shall, at minimum, incorporate the following provisions: a. Future development of the subject property shall be generally consistent with the conceptual site plan, building elevations and provisions contained herein. b. Provide supportive and proportional public and/or quasi-public spaces and places including but not limited to parks, plazas, outdoor gathering areas, open space, libraries, and schools that comprise a minimum of 10% of the development area within the site development area. c. Non-residential buildings should be proportional to and blend in with adjacent residential buildings. d. The existing homes and associated outbuildings shall be removed from the site prior to issuance of any building permits. e. A maximum of 113 residential dwelling units shall be constructed within this development as proposed. f. The developer shall grant a cross-access/ingress-egress easement to the properties to the north (parcel #S0425223010) and south (parcel #R6905260140 & #R6905260130) in accord with UDC 11-3A-3 and the Comprehensive Plan (action item #3.03.02N). A recorded copy of the easement agreement shall be submitted to the Planning Division with the first Certificate of Zoning Compliance application for the development. g. Future development shall comply with the structure and design standards listed in UDC 11 - 3A-19 and in the Architectural Standards Manual (ASM). h. A 10-foot wide segment of the City’s multi-use pathway is required along N. Linder Road in accord with the Pathways Master Plan. Landscaping shall be installed in accord with the standards listed in UDC 11-3B-12C on either side of the pathway. i. Provide pedestrian pathway connections to the church site from the north and west portions of the development. j. Before removing any of the existing trees from the site, the developer/owner shall contact the City Arborist to determine mitigation requirements for any healthy trees 4” caliper and greater that are removed from the site in accord with UDC 11-3B-10C.5. k. Unless a structure contains a mix of both residential and office, or residential and commercial land uses, maximum building size should be limited to a 20,000 square-foot building footprint in the MU-N designated area. l. A Conditional Use Permit application is required to be submitted for a multi-family development in the R-15 zoning district per UDC Table 11-2A-2. Compliance with the specific use standards listed in UDC 11-4-3-27 and the open space and site amenity standards listed in UDC 11-3G-3 is required. - 7 - m. The applicant shall submit and obtain approval of a Certificate of Zoning Compliance and Design Review application from the Planning Division, prior to submittal of any building permit applications. n. Prior to the application for any development on the subject site, sanitary sewer and water serviceability will need to be reviewed. This is due to the potential timing of development of adjacent properties and the ability or inability to create loops in the water system and to determine the routing of sanitary sewer. Staff recommends that prior to the City Council meeting, the concept plan is revised to rearrange the commercial buildings to create some form of common, usable area, such as a plaza, gathering area or green space that comprises a minimum of 10% of the development area. 2. PUBLIC WORKS DEPARTMENT 2.1 The Public Works Department has no comments on this application at this time. 3. POLICE DEPARTMENT 3.1 The Police Department has no comments on this application. 4. FIRE DEPARTMENT 4.1 All entrances, internal roads, drive aisles, and alleys shall have a turning radius of 28’ inside and 48’ outside, per International Fire Code Section 503.2.4. 4.2 Private Alleys and Fire Lanes shall have a 20’ wide improved surface capable of supporting an imposed load of 75,000 lbs. All roadways shall be marked in accordance with Appendix D Section D103.6 Signs. 4.3 Provide signage (“No Parking Fire Lane”) for all fire lanes in accordance with International Fire Code Sections 503.4 & D103.6. 4.4 Operational fire hydrants, temporary or permanent street signs, and access roads with an all- weather surface are required to be installed before combustible construction material is brought onto the site, as set forth in International Fire Code Section (IFC) 501.4 and Meridian amendment to IFC 10-4-2J. 4.5 Provide a Knox box entry system for the complex prior to occupancy as set forth in International Fire Code Section 506. 4.6 The first digit of the Apartment/Office Suite shall correspond to the floor level as set forth in International Fire Code Section 505.1. 4.7 The applicant shall work with Public Works and Planning Department staff to provide an address identification plan and a sign which meets the requirements of the City of Meridian sign ordinance and is placed in a position that is plainly legible and visible from the street or road fronting the property, as set forth in International Fire Code Section 505.1. 4.8 All portions of the buildings located on this project must be within 150’ of a paved surface as measured around the perimeter of the building as set forth in International Fire Code Section 503.1.1. 4.9 All R-2 occupancies with 3 or more units shall be required to be fire sprinkled as set forth in International Fire Code Section 903.2.8. 4.10 Buildings over 30’ in height are required to have access roads in accordance with the International Fire Code Appendix D Section D105. - 8 - 4.11 Emergency response routes and fire lanes shall not be allowed to have traffic calming devices installed without prior approval of the Fire Code Official. National Fire Protection Standard 1141, Section A5.2.18. 5. REPUBLIC SERVICES 5.1 Coordinate with Bob Olson, Republic Services (208-345-1265 office, or 208-371-1745 cell; email: ROlson@republicservices.com ) on the location and design of the trash enclosure(s) that includes recycling prior to submittal of the Certificate of Zoning Compliance application. 6. PARKS DEPARTMENT 6.1 The applicant is required to comply with the mitigation standards listed in UDC 11-3B- 10C.5 for any existing trees 4-inch caliper or greater that are removed from the site. Contact Elroy Huff, City Arborist (208-371-1755), prior to removal of any existing trees from the site to determine mitigation requirements. 6.2 Construct a 10-foot wide detached multi-use pathway along the frontage of this site on N. Linder Road in accord with the Pathways Master Plan (Eagle Island pathway). 6.3 Submit a 14-foot wide easement for the multi-use pathway along Linder Road; coordinate the details of the easement with Kim Warren, Pathways Project Manager, 208-888-3579. 7. ADA COUNTY HIGHWAY DISTRICT 7.1 Site Specific Conditions of Approval This application is for annexation and rezone only. Listed below are some of the site specific conditions of approval that the District may identify when it reviews a future development application. The District may add additional site specific conditions of approval when it reviews a specific redevelopment application. 7.1.1 Dedicate additional right-of-way to total 48-feet from the centerline of Linder Road abutting the site. 7.1.2 Provide a road trust deposit in the amount of $16,750.00 to pay for 5-foot wide detached concrete sidewalk to be constructed abutting the site, as part of ACHD’s Linder Road widening project. 7.1.3 Construct one temporary full access driveway onto Linder Road located at the site’s south property line. The driveway is restricted to a maximum width of 36-feet. Construct the driveway as a curb return type driveway with 30-foot radii. Pave the driveway, it’s full width at least 30-feet into the site beyond the edge of Linder Road. The driveway may be restricted in the future as traffic conditions warrant; as determined by ACHD. 7.1.4 Payment of impact fees is due prior to issuance of a building permit. 7.1.5 Comply with all Standard Conditions of Approval. 7.2 Standard Conditions of Approval 7.2.1 All proposed irrigation facilities shall be located outside of the ACHD right -of-way (including all easements). Any existing irrigation facilities shall be relocated outside of the ACHD right -of-way (including all easements). 7.2.2 Private Utilities including sewer or water systems are prohibited from being located within the ACHD right-of-way. 7.2.3 In accordance with District policy, 7203.3, the applicant may be required to update any existing non- compliant pedestrian improvements abutting the site to meet current Americans with Disabilities Act (ADA) requirements. The applicant’s engineer should provide documentation of ADA compliance to District Development Review staff for review. - 9 - 7.2.4 Replace any existing damaged curb, gutter and sidewalk and any that may be damaged during the construction of the proposed development. Contact Construction Services at 387-6280 (with file number) for details. 7.2.5 A license agreement and compliance with the District’s Tree Planter policy is required for all landscaping proposed within ACHD right-of-way or easement areas. 7.2.6 All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 7.2.7 It is the responsibility of the applicant to verify all existing utilities within the right -of-way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1-811-342-1585) at least two full business days prior to breaking ground within ACHD right-of-way. The applicant shall contact ACHD Traffic Operations 387-6190 in the event any ACHD conduits (spare or filled) are compromised during any phase of construction. 7.2.8 Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District’s Utility Coordinator at 387-6258 (with file numbers) for details. 7.2.9 All design and construction shall be in accordance with the ACHD Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all applicable ACHD Standards unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 7.2.10 Construction, use and property development shall be in conformance with all applicable requirements of ACHD prior to District approval for occupancy. 7.2.11 No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant’s authorized representative and an authorized representative of ACHD. 7.2.12 If the site plan or use should change in the future, ACHD Planning Review will review the site plan and may require additional improvements to the transportation system at that time. Any change in the planned use of the property which is the subject of this application, shall require the applicant to comply with ACHD Policy and Standard Conditions of Approval in place at that time unless a waiver/variance of the requirements or other legal relief is granted by the ACHD Commission. - 10 - Exhibit C: Legal Description & Exhibit Map for Annexation and Zoning & Rezone Boundaries - 11 - - 12 - - 13 - - 14 - - 15 - - 16 - - 17 - D. Required Findings from Unified Development Code 1. ANNEXATION & ZONING/REZONE (UDC 11-5B-3E) Upon recommendation from the Commission, the Council shall make a full investigation and shall, at the public hearing, review the application. In order to grant an annexation and/or rezone, the Council shall make the following findings: a. The map amendment complies with the applicable provisions of the Comprehensive Plan; Staff finds that the proposed map amendment to the R-15 and C-C zoning districts and proposed uses are consistent with the Comprehensive Plan FLUM designations of MU-N and MU-C for this site. (See section VII above for more information.) b. The map amendment complies with the regulations outlined for the proposed district, specifically the purpose statement; Staff finds that the proposed map amendment to the R-15 and C-C zoning districts is consistent with the purpose statements of the residential and commercial districts as detailed in Section VIII above. c. The map amendment shall not be materially detrimental to the public health, safety, and welfare; Staff finds that the proposed zoning amendment will not be detrimental to the public health, safety, or welfare. City utilities will be extended at the expense of the applicant. Staff recommends that the Commission and Council consider any oral or written testimony that may be provided when determining this finding. d. The map amendment shall not result in an adverse impact upon the delivery of services by any political subdivision providing public services within the City including, but not limited to, school districts; and, Staff finds that the proposed zoning amendment will not result in any adverse impact upon the delivery of services by any political subdivision providing services to this site. e. The annexation is in the best of interest of the City (UDC 11-5B-3.E). Staff finds the proposed annexation and rezone of this property is in the best interest of the City if the applicant develops the site in accord with the provisions listed in Exhibit B.